PubMed Health⌕ Search

Biomedical subjects

Jamille F Hetke

Publications and source records attributed to Jamille F Hetke.

5 recordsLinked to original sources

Polytrodes: high-density silicon electrode arrays for large-scale multiunit recording.

We developed a variety of 54-channel high-density silicon electrode arrays (polytrodes) designed to record from large numbers of neurons spanning millimeters of brain. In cat visual cortex, it was possible to make simultaneous recordings from >100 well-isolated neurons. Using standard clustering methods, polytrodes provide a quality of single-unit isolation that surpasses that attainable with tetrodes. Guidelines for successful in vivo recording and precise electrode positioning are described. We also describe a high-bandwidth continuous data-acquisition system designed specifically for polytrodes and an automated impedance meter for testing polytrode site integrity. Despite having smaller interconnect pitches than earlier silicon-based electrodes of this type, these polytrodes have negligible channel crosstalk, comparable reliability, and low site impedances and are capable of making high-fidelity multiunit recordings with minimal tissue damage. The relatively benign nature of planar electrode arrays is evident both histologically and in experiments where the polytrode was repeatedly advanced and retracted hundreds of microns over periods of many hours. It was possible to maintain stable recordings from active neurons adjacent to the polytrode without change in their absolute positions, neurophysiological or receptive field properties.

Action Potentials↗

Feasibility of using silicon-substrate recording electrodes within the auditory nerve.

The use of penetrating, silicon-substrate (i.e., "thin-film") probes within a cross-section of a sensory nerve offers the possibility of assessing the pattern and extent of fiber excitation within the nerve. We used acute cat preparations to assess the feasibility of this technique for recordings within the auditory nerve trunk. Four probe configurations fabricated by the University of Michigan Center for Neural Communication Technology were evaluated using acoustic and electric stimuli. Our main concerns were the nature of the recorded potentials and the degree of spatial selectivity provided by these probes. We also made some basic assessments of electrode-tissue compatibility. The recorded potentials were characterized as field potentials with varying degrees of spatial selectivity. In some cases, responses to pure tones demonstrated good spatial selectivity, with unique responses recorded by different electrode sites. When electrode sites were positioned at different longitudinal positions along the nerve trunk, responses with latencies characteristic of each site were recorded. These results indicate that thin-film electrodes are capable of providing spatially specific response information from sensory nerves. However, in the case of feline auditory nerves, place-specific responses were inconsistently observed, making it difficult to use this technique to obtain detailed cochleotopic maps of neural excitation. More productive results may be possible from other peripheral nerves with less complex spatial arrangements of fibers.

Acoustic Stimulation↗

Chronic neural recording using silicon-substrate microelectrode arrays implanted in cerebral cortex.

An important aspect of the development of cortical prostheses is the enhancement of suitable implantable microelectrode arrays for chronic neural recording. The objective of this study was to investigate the recording performance of silicon-substrate micromachined probes in terms of reliability and signal quality. These probes were found to consistently and reliably provide high-quality spike recordings over extended periods of time lasting up to 127 days. In a consecutive series of ten rodents involving 14 implanted probes, 13/14 (93%) of the devices remained functional throughout the assessment period. More than 90% of the probe sites consistently recorded spike activity with signal-to-noise ratios sufficient for amplitudes and waveform-based discrimination. Histological analysis of the tissue surrounding the probes generally indicated the development of a stable interface sufficient for sustained electrical contact. The results of this study demonstrate that these planar silicon probes are suitable for long-term recording in the cerebral cortex and provide an effective platform technology foundation for microscale intracortical neural interfaces for use in humans.

Action Potentials↗

Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortex.

This study investigated the use of planar, silicon-substrate microelectrodes for chronic unit recording in the cerebral cortex. The 16-channel microelectrodes consisted of four penetrating shanks with four recording sites on each shank. The chronic electrode assembly included an integrated silicon ribbon cable and percutaneous connector. In a consecutive series of six rats, 5/6 (83%) of the implanted microelectrodes recorded neuronal spike activity for more than six weeks, with four of the implants (66%) remaining functional for more than 28 weeks. In each animal, more than 80% of the electrode sites recorded spike activity over sequential recording sessions during the postoperative time period. These results provide a performance baseline to support further electrode system development for intracortical neural implant systems for medical applications.

Action Potentials↗

Recording and marking with silicon multichannel electrodes.

This protocol describes an implementation of recording and analysis of evoked potentials in the hippocampal cortex, combined with lesioning using multichannel silicon probes. Multichannel recording offers the advantage of capturing a potential field at one instant in time. The potentials are then subjected to current source density (CSD) analysis, to reveal the layer-by-layer current sources and sinks. Signals from each channel of a silicon probe (maximum 16 channels in this study) were amplified and digitized at up to 40 kHz after sample-and-hold circuits. A modular lesion circuit board could be inserted between the input preamplifiers and the silicon probe, such that any one of the 16 electrodes could be connected to a DC lesion current. By making a lesion at the electrode showing a physiological event of interest, the anatomical location of the event can be precisely identified, as shown for the distal dendritic current sink in CA1 following medial perforant path stimulation. Making two discrete lesions through the silicon probe is useful to indicate the degree of tissue shrinkage during histological procedures. In addition, potential/CSD profiles were stable following small movements of the silicon probe, suggesting that the probe did not cause excessive damage to the brain.

Animals↗