PubMed Health⌕ Search

Biomedical subjects

Jan Ake Jönsson

Publications and source records attributed to Jan Ake Jönsson.

At least 19 recordsLinked to original sources

Development of a simple hollow fibre supported liquid membrane extraction method to extract and preconcentrate dinitrophenols in environmental samples at ng L(-1) level by liquid chromatography.

An easy and rapid hollow-fibre supported liquid membrane method (HFSLM) has been developed to extract and determinate the total concentration of four dinitrophenols in environmental water at ng L(-1) level. This extraction method provides a high selectivity, short extraction time and very low cost for real samples. It is a three-phase system, aqueous-organic-aqueous, where the organic solvent is held into the fibre pores, being in contact with the two other phases. The organic phase is formed by two different organic solvents, with two different polarities, n-undecane and toluene (1:1). The optimization step was performed using a three-variable Doehler design, involving three factors, stirring speed, fibre length and sample volume. The organic phase composition, as well as the pH of the acceptor and donor phases was also optimized. The extraction equilibrium was reached after 30 min, after which essentially the total amount (90-80%) of the four dinitrophenolic compounds were extracted from the sample. Better repeatability and reproducibility at the expense of lower enrichment factors was obtained compared with other methods, employing incomplete extraction during a fixed time. The matrix effect was tested by performing extractions from leachate water and river water. This method is linear in the range 0.1-100 microgL(-1) in different matrices, with detection limit around 100 ng L(-1), after extraction of 6 mL of sample and using high performance liquid chromatography for final analysis.

Analytic Sample Preparation Methods↗

Equilibrium sampling of freely dissolved alkylphenols into a thin film of 1-octanol supported on a hollow fiber membrane.

A new negligible depletion extraction procedure was proposed for equilibrium sampling of 4-tert-octylphenol (OP) and 4-nonylphenol (NP) into a thin film of 1-octanol supported on a hollow fiber membrane. This thin liquid film extraction technique was directed at the determination of (1) freely dissolved concentrations, (2) distribution coefficients to 1-octanol (D(ow)), and (3) binding to dissolved organic matter (DDOC). The sampling device was prepared by dipping pieces of polypropylene microporous hollow fiber membrane (10-mm length, 30-microm wall thickness, 240-microm inner diameter) into 1-octanol for a few seconds to impregnate the pores of the hollow fiber wall. After stirring in 100 mL of sample solution for 24 h, the sampling device was harvested and desorbed with 30 microL of methanol, of which 20 microL was injected for HPLC analysis. With the measured D(ow) of a chemical and its equilibrium concentration in the 1-octanol sampling phase (C(octanol)), the freely dissolved concentration (Cfree) was calibrated based on Cfree = C(octanol)/D(ow). Measured log Dow values of OP (4.32 +/- 0.06) and NP (4.79 +/- 0.02) were independent of the chemical concentration, only minimally affected by the environmentally relevant pH, buffering capacity, and salinity of samples, and agreed well with reported values. Log DDOC values of OP (4.89 +/- 0.43) and NP (5.14 +/- 0.37), determined in Aldrich humic acid solution, agreed with reported partition coefficients to organic carbon (log Koc) for particles in river water and effluent wastewater. Short equilibration times and high enrichment factors were obtained for both analytes due to the high surface to volume ratio of the new sampler. The technique was successfully applied to determine Cfree of OP and NP in real water samples and to study their association with humic acids and bovine albumin.

Journal Article↗

Determination of short-chain fatty acids in serum by hollow fiber supported liquid membrane extraction coupled with gas chromatography.

A method based on hollow fiber supported liquid membrane extraction coupled with a gas chromatograph equipped with flame ionization detector (GC-FID) was developed for the determination of six short-chain fatty acids including acetic acid, propionic acid, i-butyric acid, n-butyric acid, i-valeric acid and n-valeric acid in serum. Hollow fiber supported liquid membrane extraction was employed for preconcentration and clean-up of the samples. The fatty acids were extracted from the acidic donor (diluted serum) into a liquid membrane formed in the wall of the hollow fiber with 10% tri-n-octylphoshphine oxide (TOPO) in di-n-hexyl ether, and then extracted back into a basic acceptor solution filled in the lumen of the hollow fiber. After being acidified with HCl, the acceptor was directly analyzed by GC-FID. The acceptor concentration, donor pH, membrane liquid and extracting time were optimized giving an enrichment factor up to 155 times. The good linearity (r(2)>0.980), reasonable recovery (87.2-121%), and satisfactory intra-assay (8.2-11.5%) and inter-assay (6.1-11.6%) precision illustrated the good performance of the present method. Limits of detection (LOD) ranged from 0.04 to 0.24 microM and limits of quantification (LOQ) varied from 0.13 to 0.80 microM.

Chromatography, Gas↗

Evaluating the impacts of some environmentally relevant factors on the availability of bisphenol A with negligible-depletion SPME.

The effect of some environmentally relevant factors including salinity, pH, and humic acids on the availability of bisphenol A (BPA) was evaluated by using the negligible-depletion solid-phase microextraction (nd-SPME) biomimetic method. With the variation of salinity (0-500 mM NaCl) and pH (5.0-8.5) of aqueous solutions, the partition coefficients of BPA between the nd-SPME fiber and the aqueous solution varied in the range of logD=3.55-3.86, which indicates that the salinity and pH can influence the availability of BPA. By using Acros humic acid as model dissolved organic matter (DOM), it was also demonstrated that the environmental factors such as salinity and pH could affect the partitioning of BPA between DOM and aqueous solutions. The determined partition coefficients of BPA between dissolved organic carbon (DOC) and aqueous solutions were in the range of logD(DOC)=4.03-5.60 for Acros humic acid solutions with 1-50 mg l(-1) DOC. The influence of salinity and pH on logD(DOC) was more significant at low concentration (0-5 mg l(-1)) of DOC.

Benzhydryl Compounds↗

Extraction and preconcentration of salbutamol and terbutaline from aqueous samples using hollow fiber supported liquid membrane containing anionic carrier.

This paper presents a new three-phase liquid-phase microextraction (LPME) strategy for extraction and preconcentration of salbutamol (SB) and terbutaline (TB) from aqueous samples, including urine. The drugs were extracted from 11 ml of aqueous sample (source phase; SP) into an organic phase with microliter volume located inside the pores of a polypropylene hollow fiber, and then back-extracted into 24 microl of a second aqueous solution as the receiving phase (RP), located in the lumen of the hollow fiber. In preliminary experiments, we tried to transport the drugs using a pH gradient between the two sides of the hollow fiber. Due to the existence of both amine and phenolic groups on the drugs, very little transport occurred and enrichment factors (EF) less than one were obtained. Further experiments were done in the presence of bis(2-ethylhexyl) monohydrogenphosphoric acid (D2EHPA) or methyltrioctylammonium chloride (Aliquat 336) in the organic phase, to extract drugs from acidic and basic matrices, respectively. Results showed that transport of drugs from alkaline solution into 1M of sodium bromide occurred when the membrane was impregnated with dihexyl ether containing 20% Aliquat 336. To optimize the EF, the effects of different parameters such as the nature of organic solvent used to impregnate the membrane, compositions and volumes of SP and RP, type and concentration of carrier, extraction time and stirring rate were investigated. Optimal results were obtained in the presence of 0.005 M of NaOH (pH 11.70) in the SP, 1M of NaBr in the RP, 20% of Aliquat 336 in dihexyl ether as membrane impregnation solvent, stirring rate of 500 rpm and extraction time of 60 min. Under these conditions, enrichment factors of 52.9 and 213.1, dynamic linear ranges of 20-5000 and 10-5000, and limits of detection of 2.5 and 0.5 ng/ml were obtained for salbutamol and terbutaline, respectively. Also determination of drugs in environmental water and urine samples in the range of nanograms per millilitre with RSDs<10% was possible using HPLC-photodiode array detection or HPLC-MS.

Albuterol↗

Determination of trace levels of dinitrophenolic compounds in environmental water samples using hollow fiber supported liquid membrane extraction and high performance liquid chromatography.

A hollow fiber supported liquid membrane extraction method for the liquid chromatographic determination of dinitrophenolic compounds at ppt levels has been developed. Different variables affecting the extraction process, such as extraction time, shaking speed, acceptor pH, acceptor buffer concentration, salt content and humic acids have been studied. Enrichment factors up to 7000 times were obtained. Validation of the method included calibration experiments and studies of the linearity of the responses in different matrices. Good linearity was obtained in the environmental matrices evaluated. Detection limits range from 6.0 to 8.0 ng/L, and the relative standard deviations do not exceed 7% in terms of repeatability.

Chemical Fractionation↗

Rapid determination of short-chain fatty acids in colonic contents and faeces of humans and rats by acidified water-extraction and direct-injection gas chromatography.

Short-chain fatty acids (SCFAs) have attracted much attention recently because of their positive physiological effects. In this work, a rapid and reliable gas chromatographic method for determination of eight SCFAs, in colonic and faecal samples from rats and humans has been developed and validated. The methodology involves extraction of the SCFAs in water before a direct injection procedure on a FFAP capillary column. A stock standard solution containing acetic acid, propionic acid, n-butyric acid, i-butyric acid, n-valeric acid, i-valeric acid, n-caproic acid and n-heptanoic acid was prepared and used. A high linearity (r2 > 0.9990), low quantification limit (2.38-30.14 microm) and high recovery for most acids were obtained. Acidification of faecal samples was found to be crucial for quantitative determination of the SCFAs, and adjustment of pH to 2-3 was regarded as necessary. Glass wool inserted in the glass liner of the injection port proved effective in preventing the contamination of the column by non-volatiles, and 12% formic acid reduced the ghost peak that appeared gradually after several injections. After validation, the methodology was applied on two faecal samples from rats fed diets containing different amount of dietary fibre and one faecal sample from human fed a normal diet to test the accuracy of the developed method.

Adult↗

Equilibrium sampling through membranes of freely dissolved copper concentrations with selective hollow fiber membranes and the spectrophotometric detection of a metal stripping agent.

A sensitive spectrophotometric method for the determination of freely dissolved copper concentrations in aqueous samples after preconcentration with hollow fiber membrane extraction has been developed. The method is based on the equilibrium sampling through a selective membrane into an acceptor solution containing 4-(pyridyl-2-azo)resorcinol (PAR), which serves as stripping agent and metal indicator. Negligible extraction of interferences and equilibrium enrichment of copper allowed for selective spectrophotometric determination of the Cu-PAR complex. Some important extraction parameters such as acceptor composition, shaking, equilibrium time, and sample volume were studied. The optimized methodology showed good linearity in the range of 5-100 microg/L, an enrichment factor of 93, good repeatability and reproducibility (RSDs < 6%, n = 6), and a detection limit of 4 microg/L. The cationic metals Ni2+, C(2+, Cd2+, Fe3+, Pb2+, Zn2+, and Mn2+ were shown not to interfere with the measurement of Cu2+. Measurements on samples containing mixtures of various ligands and cations were in good agreement with theoretically calculated concentrations, and the method was also applied to environmental samples. The developed technique requires less labor and less sophisticated equipment than conventional methods typically based on atomic absorption spectrometry or ICP.

Journal Article↗

Equilibrium sampling through membrane based on a single hollow fibre for determination of drug-protein binding and free drug concentration in plasma.

The determination of drug-protein binding and free drug concentration in plasma applying the equilibrium sampling through membrane (ESTM) technique has been studied using supported liquid membrane extraction in a single hollow fibre without any membrane carrier. In the extraction setup, the donor phase (plasma or buffer) was placed in the vial, into which was immersed the hollow fibre with the acceptor phase situated in the lumen. This proposed technique was applied to study the drug-protein binding of five local anaesthetics and two antidepressants as model substances, and the influence of the total drug concentration on the drug-protein binding was investigated. The brief theoretical background for determination of the drug-protein binding under equilibrium conditions is described. The developed method shows a new, improved and simple procedure for determination of free drug concentration in plasma and extent of drug-protein binding.

Anesthetics, Local↗

Equilibrium sampling through membranes of freely dissolved chlorophenols in water samples with hollow fiber supported liquid membrane.

The freely dissolved concentration (C(free)) of pollutants is generally believed to be bioavailable and thus responsible for toxic effects. The C(free) of organic weak acids and bases consists of a dissociated and a nondissociated fraction. By using chlorophenols as model compounds, a negligible-depletion extraction technique, equilibrium sampling through membranes (ESTM), was developed for the measurement of the nondissociated part of the C(free). Polypropylene hollow fiber membranes (280-microm i.d., 50-microm wall thickness, 0.1-microm pore size, 15-cm length) were impregnated with undecane in the pores in the fiber wall as liquid membrane and filled with buffer solution in the lumen as acceptor. Then, the hollow fiber membranes were placed into the sample (donor) for an equilibrium extraction after sealing the two ends. The chlorophenol concentrations in the acceptor were then determined by direct injection into a HPLC system. Finally, the C(free) of the nondissociated and the dissociated species of a chlorophenol were calculated based on its measured concentration in the acceptor, its pK(a) value, and the measured pH in sample and acceptor. Theoretically calculated distribution coefficients (D = 8-970) agree well with the experimental enrichment factors (E(e(max)) = 6-1124), and the equilibration time was observed to increase with increasing distribution coefficients (hours to days). The freely dissolved concentration of five chlorophenols, with a wide range of pK(a) (4.9-9.2) and log K(ow) (2.35-5.24), were successfully determined in model solutions of humic acids and at low-ppb levels in river and leachate water.

Buffers↗

Determination of free copper concentrations in natural waters by using supported liquid membrane extraction under equilibrium conditions.

A method is described for measurement of freely dissolved copper concentrations in natural water samples using supported liquid membrane (SLM) extraction under equilibrium conditions, a technique denoted "equilibrium sampling through membranes" (ESTM). For this purpose, 1,10-dibenzyl-1,10-diaza-18-crown-6 as neutral carrier and oleic acid were used in the membrane phase. The main variables optimised were the carrier used to form the metal complexes, the organic solvent used in the membrane, the countercation, pH, the ligand used in the acceptor phase, the extraction time, and the flow rate of the donor phase. After the optimisation process an enrichment factor of 18.5 was obtained. Equilibrium conditions were reached after extraction for 60 min if a flow rate of 1.0 mL min(-1) or greater was used. When different ligands such as humic acids, phthalic acid, and EDTA were added to the sample solution, and sample pH ranged from 6 to 8, the results obtained for freely dissolved copper concentrations were in a good agreement with results from speciation calculations performed with Visual Minteq V 2.30, Cheaqs V L20.1, and WinHumic V. The developed technique was applied to analysis of stream and leachate water.

Journal Article↗

Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in paints followed by gas chromatography-flame ionization detection.

Solid-phase microextraction (SPME) with a disposable ionic liquid (IL) coating was developed for headspace extraction of benzene, toluene, ethylbenzene, and xylenes (BTEX) in paints. The SPME fiber was coated with IL prior to every extraction, then the analytes were extracted and desorbed on the injection port of gas chromatography, and finally the IL coating on the fiber was washed out with solvents. The coating and washing out of IL from the fiber can be finished in a few minutes. This disposable IL-coated fiber was applied to determine BTEX in water-soluble paints with results in good agreement with that obtained by using commercially available SPME fibers. For all the four studied paints samples, the benzene contents were under the detection limits, but relatively high contents of toluene, ethylbenzene and xylenes (56-271 microg g(-1)) were detected with spiked recoveries in the range of 70-114%. Compared to the widely used commercially available SPME fibers, this proposed disposable IL-coated fiber has much lower cost per determination, comparable reproducibility (RSD < 11%), and no carryover between each determination. Considering that IL possess good extractability for various organic compounds and metals ions, and that task-specific IL can be designed and synthesized for selective extraction of target analytes, this disposable IL coating SPME might has great potential in sample preparation.

Benzene↗

Determination of drug-protein binding using supported liquid membrane extraction under equilibrium conditions.

A technique for determination of drug-protein binding based on a membrane extraction technique termed "equilibrium sampling through membrane (ESTM)" is presented. It involves the establishment of an equilibrium between an aqueous buffer and either a blood plasma sample or a matched buffer, both containing the drug. Analysis of the aqueous buffer in the two cases gives the drug-protein binding. The principle bypasses some sources of systematic error found with common techniques for this measurement based on e.g. ultrafiltration, as it senses the equilibrium conditions without disturbing the sample. The technique is applied to some local anesthetic drugs as model substances and two alternative ways for the evaluation are presented. Results with these evaluation methods are compared with literature values for the drug-protein binding of these compounds. It is found that the drug-protein binding values obtained are lower than literature values, which is attributed to reduced systematic error.

Anesthetics, Local↗

Miniaturized and automated sample pretreatment for determination of PCBs in environmental aqueous samples using an on-line microporous membrane liquid-liquid extraction-gas chromatography system.

A new, fast, and automated sample pretreatment technique for determination of lipophilic organic compounds in aqueous samples has been developed and applied to the determination of polychlorinated biphenyls (PCBs) in environmental river water. It is based on miniaturized microporous membrane liquid-liquid extraction coupled on-line to gas chromatography (GC) with electron capture detection. The heart of the system that simultaneously connects the sample pretreatment step to the final GC analysis has been named the extracting syringe (ESy). The ESy carries a miniaturized membrane extraction card attached to an electrically and mechanically designed installment and is mounted directly over a GC injector for fully automated injection of the extract. A method was developed to extract 10 PCB congeners from 1-mL water samples (after addition of 40% acetonitrile) with an extraction time of 10 min. The optimized methodology showed good linearity (in the dynamic concentration range of 5 ng L(-)(1)-1 microg L(-)(1)), enrichment factors of 33-40 times, repeatable extractions (RSD 2-5%, n = 4), and low detection limits (2-3 ng L(-)(1)). Acetonitrile had to be added to the samples in order to overcome the influence of PCB adsorption on the repeatability of extraction and enrichment and to minimize the overall memory effect (OME). OME and carryover depended not only on the concentration of the organic solvent added to the sample and that used in the washing procedure but also on whether the extracting card was changed or not. When an optimized washing procedure was applied, the OME was approximately 0.2% at high concentrations (i.e., 1 microg L(-)(1)). When each extraction took place in a new extraction card, no OME was detected. Additionally, no significant adsorption onto glass surfaces or a matrix effect on extraction was noticed. The main features of this methodology are good extraction repeatability, low detection limits at short extraction time, and the unsurpassed characteristic of no detectable OME in the entire system when each sample is processed in a new card. The total consumption of organic (nonchlorinated) solvents is less than 5 mL per sample.

Journal Article↗

Immuno-SLM-a combined sample handling and analytical technique.

Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted access (RA) column is used for the separation of the two tracer fractions (Ag* and AbAg*) formed, and the eluted AbAg* fraction is measured downstream by a fluorescence detector. Factors influencing the optimum immuno-SLM extraction parameters, i.e., donor flow rate, extraction time and type of Ab, were investigated for immuno extraction of the model analyte atrazine. Immuno-SLM coupled to FFIA (immuno-SLM-FFIA) and FFIA alone were compared in terms of the assay sensitivities obtained and the sample matrix influence. The concentration at the mid-point of the calibration curve (IC(50)) was 16.0+/-1.4 and 36+/-16 microg/l, the limit of detection (LOD) was 2.0+/-1.1 and 20+/-10 microg/l, and the dynamic range was 2-100 and 20-500 microg/l atrazine for immuno-SLM-FFIA and FFIA, respectively. The matrix influence on the FFIA was significant in orange juice and surface water, whereas the influence was minor for immuno-SLM-FFIA with recoveries between 104% and 115% for 5 microg/l atrazine in tap water, orange juice and river water.

Antibodies↗

On-line automated sample preparation for liquid chromatography using parallel supported liquid membrane extraction and microporous membrane liquid-liquid extraction.

An automated system was developed for analysis of non-polar and polar ionisable compounds at trace levels in natural water. Sample work-up was performed in a flow system using two parallel membrane extraction units. This system was connected on-line to a reversed-phase HPLC system for final determination. One of the membrane units was used for supported liquid membrane (SLM) extraction, which is suitable for ionisable or permanently charged compounds. The other unit was used for microporous membrane liquid-liquid extraction (MMLLE) suitable for uncharged compounds. The fungicide thiophanate methyl and its polar metabolites carbendazim and 2-aminobenzimidazole were used as model compounds. The whole system was controlled by means of four syringe pumps. While extracting one part of the sample using the SLM technique. the extract from the MMLLE extraction was analysed and vice versa. This gave a total analysis time of 63 min for each sample resulting in a sample throughput of 22 samples per 24 h.

Automation↗

PD fluids contain high concentrations of cytotoxic GDPs directly after sterilization.

OBJECTIVE: Glucose degradation products (GDPs) in peritoneal dialysis (PD) fluids are cytotoxic and affect the survival of the peritoneal membrane. One of the most reactive GDPs in PD fluids is 3,4-dideoxyglucosone-3-ene (3,4-DGE). 3,4-DGE has been reported as an intermediate between 3-deoxyglucosone (3-DG) and 5-hydroxymethyl furaldehyde (5-HMF) during degradation of glucose. In PD fluids, 3,4-DGE exists in a temperature-dependent equilibrium with a pool of unidentified substances. The aim of this study was to explore this equilibrium and its temperature dependence during the first months of storage after the sterilization procedure. METHODS: GDPs and inhibition of cell growth (ICG) were measured directly after sterilization of the PD fluid and during storage at different temperatures for 60 days. The following GDPs were analyzed: 3-DG, 3,4-DGE, 5-HMF, formaldehyde, acetaldehyde, glyoxal, and methylglyoxal. RESULTS: Immediately after sterilization, the concentration of 3,4-DGE was 125 micromol/L. During the first weeks of storage, it decreased by about 80%. At the same time, the 3-DG concentration increased. None of the other GDPs were significantly affected. Cytotoxicity correlated well with the concentration of 3,4-DGE. When pure 3,4-DGE was substituted for the lost amount of 3,4-DGE after 30 days of storage, the initial ICG was almost completely regained. CONCLUSIONS: Heat sterilization of PD fluids promotes the formation of large quantities of 3,4-DGE, rendering the fluid highly cytotoxic. During storage, the main part of 3,4-DGE is reversibly converted in a temperature-dependent manner to a less cytotoxic pool, consisting mainly of 3-DG. Cytotoxicity seems to be dependent exclusively on 3,4-DGE. In order to avoid higher levels of 3,4-DGE concentrations, PD fluids should not be used too soon after sterilization and should not be stored at temperatures above room temperature.

Aldehydes↗

Take care in how you store your PD fluids: actual temperature determines the balance between reactive and non-reactive GDPs.

OBJECTIVE: During heat sterilization and during prolonged storage, glucose in peritoneal dialysis fluids (PDF) degrades to carbonyl compounds commonly known as glucose degradation products (GDPs). Of these, 3,4-dideoxyglucosone-3-ene (3,4-DGE) is the most cytotoxic. It is an intermediate in degradation between 3-deoxyglucosone (3-DG) and 5-hydroxymethyl-2-furaldehyde (5-HMF). We have earlier reported that there seems to be equilibrium between these GDPs in PDF. The aim of the present study was to investigate details of this equilibrium. METHODS: Aqueous solutions of pure 3-DG, 3,4-DGE, and 5-HMF were incubated at 40 degrees C for 40 days. Conventional and low-GDP fluids were incubated at various temperatures for up to 3 weeks. Formaldehyde, acetaldehyde, glyoxal, methylglyoxal, 3-DG, 3,4-DGE, and 5-HMF were analyzed using high performance liquid chromatography. RESULTS: Incubation of 100 micromol/L 3,4-DGE resulted in the production of 36 micromol/L 3-DG, 4 micromol/L 5-HMF, and 40 micromol/L unidentified substances. With the same incubation, 200 micromol/L 3-DG was converted to 9 micromol/L 3,4-DGE, 6 micromol/L 5-HMF, and 14 micromol/L unidentified substances. By contrast, 100 micromol/L 5-HMF was uninfLuenced byincubation. In a conventional PDF incubated at 60 degrees C for 1 day, the 3,4-DGE concentration increased from 14 to a maximum of 49 micromol/L. When the fluids were returned to room temperature, the concentration decreased but did not reach original values until after 40 days. In a low GDP fluid, 3,4-DGE increased and decreased in the same manner as in the conventional fluid but reached a maximum of only 0.8 micromol/L. CONCLUSIONS: Considerable amounts of 3,4-DGE may be recruited by increases in temperature in conventional PDFs. Lowering the temperature will again reduce the concentration but much more time will be needed. Precursors for 3,4-DGE recruitment are most probably 3-DG and the enol 3-deoxyaldose-2-ene, but not 5-HMF. Considering the ease at which 3,4-DGE is recruited from its pool of precursors and the difficulty of getting rid of it again, one should be extremely careful with the temperatures conventional PDFs are exposed to.

Animals↗