Beat-to-beat effects of intraaortic balloon pump timing on left ventricular performance in patients with low ejection fraction.

BACKGROUND: Intraaortic balloon counterpulsation (IABP) timing errors during arrhythmia may result in afterload increases which may negatively influence left ventricular (LV) ejection and LV mechanical dyssynchrony. The aim of our study was to determine beat-to-beat effects of properly timed IABP, premature IAB inflation, and late IAB deflation on LV performance and LV mechanical dyssynchrony in heart failure patients undergoing cardiac surgery. METHODS: In 15 patients, LV pressure-volume relations and LV dyssynchrony were measured by conductance volume catheter. Properly timed IABP was evaluated at a 1:1 assist ratio within a 10 seconds time-span. Premature IAB inflation and late IAB deflation were evaluated at a 1:4 assist ratio. RESULTS: Properly timed 1:1 IABP acutely decreased LV end-systolic volume by 6.1% (p < 0.0001) and LV end-systolic pressure by 17.5% (p < 0.0001) due to decreased aortic impedance. Stroke volume (SV) increased by 14% (p < 0.0001), which correlated markedly with a decrease of LV mechanical dyssynchrony (p < 0.0001). The largest SV increases occurred in patients with lowest contractile state. Premature IAB inflation decreased SV by 20% (p < 0.0001) due to abrupt increase of LV afterload during late ejection. Late IAB deflation increased SV and stroke work by 18% (p < 0.0001) and 16% (p < 0.01) respectively, due to increased afterload during early ejection and decreased afterload during late ejection. CONCLUSIONS: Left ventricular performance during IABP is causally related to changes in LV afterload, and the timing of these changes in relation to contraction or relaxation phases, to LV mechanical dyssynchrony and to contractile state.

Humans↗

Automatic intraaortic balloon pump timing using an intrabeat dicrotic notch prediction algorithm.

PURPOSE: The efficacy of intraaortic balloon counterpulsation (IABP) during arrhythmic episodes is questionable. A novel algorithm for intrabeat prediction of the dicrotic notch was used for real time IABP inflation timing control. DESCRIPTION: A windkessel model algorithm was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was predicted using a percentage of calculated peak flow. Automatic inflation timing was set at intrabeat predicted dicrotic notch and was combined with automatic IAB deflation. EVALUATION: Prophylactic IABP was applied in 27 patients with low ejection fraction (< 35%) undergoing cardiac surgery. Analysis of IABP at a 1:4 ratio revealed that IAB inflation occurred at a mean of 0.6 +/- 5 ms from the dicrotic notch. In all patients accurate automatic timing at a 1:1 assist ratio was performed. Seventeen patients had episodes of severe arrhythmia, the novel IABP inflation algorithm accurately assisted 318 of 320 arrhythmic beats at a 1:1 ratio. CONCLUSIONS: The novel real-time intrabeat IABP inflation timing algorithm performed accurately in all patients during both regular rhythms and severe arrhythmia, allowing fully automatic intrabeat IABP timing.

Aged↗

Feasibility study of a fiber-optic system for invasive blood pressure measurements.

A comparative study was conducted to evaluate the feasibility of a fiber-optic sensor in invasive blood pressure measurements. Static and wide-bandwidth stimuli were offered to the fiber-optic, Millar, Baxter, and Sentron devices to measure static transfer function and transient response. Animal experiments focused on offset drift, dynamic accuracy, and electromagnetic sensitivity. Compared to the Millar, Sentron, and Baxter devices, the fiber-optic sensor had a near-identical static transfer function. Gain and offset errors were < 3.4% and < 0.25%, respectively. Hysteresis nonlinearity was < 0.1%. The dynamic accuracy of the fiber-optic system matched that of the Millar and Sentron systems. Time delay was < 1 msec. Maximum rate of change was > 30,000 mm Hg/sec and bandwidth was 0-150 Hz minimum. Offset drift was 0.6 +/- 0.03 mm Hg. Application of diathermy highlighted the fiber-optic sensor's excellent electromagnetic disturbance rejection. The fiber-optic system appears to be a reliable, high-fidelity pressure monitor in demanding clinical environments.

Animals↗

Percutaneous venous thrombectomy using the Arrow-Trerotola percutaneous thrombolytic device (PTD) with temporary caval filtration: in vitro investigations.

PURPOSE: To evaluate the size and quantity of downstream emboli after thrombectomy using the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with or without temporary filtration for extensive iliofemoral and iliocaval thrombi in an in vitro flow model. METHODS: Iliocaval thrombi were simulated by clotted bovine blood in a flow model (semilucent silicone tubings, diameter 12-16 mm). Five experimental set-ups were performed 10 times each; thrombus particles and distribution were measured in the effluent. First, after retrograde insertion, mechanical thrombectomy was performed using the PTD alone. Then a modified self-expanding tulip-shaped temporary vena cava stent filter was inserted additionally at the beginning of each declotting procedure and removed immediately after the intervention without any manipulation within or at the filter itself. In a third step, the filter was filled with thrombus only. Here, two experiments were performed: Careful closure within the flow circuit without any additional fragmentation procedure and running the PTD within the filter lumen, respectively. In the final set-up, mechanical thrombectomy was performed within the thrombus-filled tubing as well as in the filter lumen. The latter was closed at the end of the procedure and both devices were removed from the flow circuit. RESULTS: Running the PTD in the flow circuit without filter protection led to a fragmentation of 67.9% (+/-7.14%) of the clot into particles < or =500 microm; restoration of flow was established in all cases. Additional placement of the filter safely allowed maceration of 82.9% (+/-5.59%) of the thrombus. Controlled closure of the thrombus-filled filter within the flow circuit without additional mechanical treatment broke up 75.2% (+/-10.49%), while additional mechanical thrombectomy by running the PTD within the occluded filter led to dissolution of 90.4% (+/-3.99%) of the initial clot. In the final set-up, an overall fragmentation rate of 99.6% (+/-0.44%) was achieved. CONCLUSIONS: The combined use of the Arrow-Trerotola PTD and a temporary vena cava stent filter proved to be effective for even large clot removal in this experimental set-up.

Alloys↗

Performance of a real-time dicrotic notch detection and prediction algorithm in arrhythmic human aortic pressure signals.

A novel algorithm for real-time detection and prediction of the dicrotic notch from aortic pressure waves was evaluated in arrhythmic aortic pressure signals from heart failure patients. A simplified model of the arterial tree was used to calculate real-time aortic flow from aortic pressure. The dicrotic notch was detected at the first negative dip from the calculated flow, prediction of the notch was performed using a percentage of the decreasing flow. The performance of the real-time dicrotic notch detection algorithm (RTDND) was evaluated during severe arrhythmia from aortic pressure signals of 12 patients. The RTDND was able to detect the dicrotic notch in 98.1%. No false positive dicrotic notch identifications were observed. Prediction of the dicrotic notch was tested at 40%, 20%, and 0% of the decreasing calculated aortic flow. The mean time-delays to the notch were 68 +/- 14 ms, 55 +/- 12 ms, and 43 +/- 8 ms, respectively. Given these small variability, intra-beat prediction of the dicrotic notch may be used for real-time intra-aortic balloon counterpulsation inflation timing.

Aged↗