Surgical treatment of multiple atherosclerotic coronary artery aneurysms in a patient presenting with acute myocardial infarction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Jan Gummert.
Explore the source record for details and available documents.
BACKGROUND AND AIM OF THE STUDY: Reversal of myocardial collagen gene expression was examined in parallel to left ventricular reverse remodeling after surgical correction of experimental aortic stenosis. METHODS: A standard growing sheep model (age at baseline 6-8 months) was used. Measurements were performed at baseline (point A) when inducing left ventricular hypertrophy (LVH) through supracoronary banding, at 8.3 +/- 1.0 months later at surgical correction (point B), and after another 10.1 +/- 2.0 months during final examinations (point C). Gene expression for collagen I and III was also studied. RESULTS: Left ventricular function was stable throughout the study. The left ventricular mass index (LVMI) was 82 +/- 21 g/m2 at point A, 150 +/- 33 g/m2 at B, and 78 +/- 18 g/m2 at C (p <0.01). Myocardial fiber diameter was 11.3 +/- 0.8, 15.9 +/- 1.2 and 11.4 +/- 1 microm at points A, B and C, respectively (p <0.01). Protein expression for collagen I was 0.71 +/- 0.2 (at A), 1.13 +/- 0.3 (at B) and 0.85 +/- 0.4 (at C) (p <0.01), while that for collagen III was 0.72 +/- 0.4 (at A), 1.26 +/- 0.8 (at B) and 0.83 +/- 0.3 (at C) (p <0.01). There was a significant correlation between changes in LVMI and myocardial collagen expression. CONCLUSION: Complete reverse remodeling with regression of LVH and myocardial collagen protein expression can be anticipated after surgical correction of experimental aortic stenosis.
BACKGROUND: Our aim is to describe the clinical experience with stentless mitral valve (SMV) replacement with special focus on the functionality of the SMV. METHODS: Fifty-two patients (68 +/- 8.5 years old; 36 female) have been prospectively evaluated since August 1997. The chordally supported SMV (Quattro) was implanted for mitral stenosis (n = 26), severe incompetence (n = 17), or mixed lesion (n = 9). Preoperative New York Heart Association class was 3.1 +/- 0.6. Twenty patients received additional intraoperative ablation therapy. Mean follow-up is 37.3 +/- 18.7 months (range, 1 to 65). RESULTS: Surgery was performed using conventional sternotomy (33) or anterolateral minithoracotomy (19). Atrial rhythm was reestablished in 17 of 20 patients. Six patients operated on early in this series required reoperation, 2 for paravalvular leakage, 2 for functional stenosis, 1 with pannus formation due to underlying rheumatoid disease, and 1 for papillary flap rupture after 5.1 years. Mortality was 1 perioperative (1.9%, nonvalve related) and 1 after reoperation due to multiorgan failure. During late follow-up (30 +/- 7 months postoperatively) 5 patients died of noncardiac causes. Regular echocardiographic control revealed good SMV function (maximum transmitral blood flow velocity 1.7 +/- 0.2 m/s; mean transmitral pressure gradient 3.9 +/- 1.2 mm Hg) and well-preserved ejection fraction postoperatively as well as at most recent follow-up. CONCLUSIONS: The clinical experience after 5.5 years of SMV implantation is promising. Preservation of annuloventricular continuity is advantageous. However, long-term durability remains to be proved.
BACKGROUND: Standard stented aortic xenograft valves have not yet been compared regarding their hemodynamic function using a stratified intraoperative randomization protocol. METHODS AND RESULTS: 100 patients were prospectively included after intraoperative metric sizing of the decalcified aortic annulus. They received Mosaic (M) or Perimount (P) aortic valve replacement. Patient age was 73+/-5 years, 51 were female, and New York Heart Association (NYHA) functional class was 2.8+/-0.5. The 21-mm annulus group consisted of 5 (M)/7 (P) patients, the 23-mm annulus group of 20 (M)/20 (P), the 25-mm annulus group of 18 (M)/19 (P), and the 27-mm annulus group of 4 (M)/7 (P) patients, respectively. Hemodynamic function was evaluated using transthoracic echocardiography before discharge and at follow-up (438+/-352 days). Surgery was uncomplicated in all patients. Labeled valve sizes were 0.93 (M) and 1.05 (P) mm smaller than the annulus diameters (p=NS). In-hospital mortality was 5%, all nonvalve-related. Transvalvular blood flow velocities and transvalvular pressure gradients were significantly lower in the 25 P versus the 25 M group at baseline and in the 23 P and 25 P groups at follow-up. There was a significant regression of left ventricular mass index in all patients at follow-up. However, left ventricular mass regression was more pronounced after P aortic valve replacement. CONCLUSIONS: Labeled sizes of prosthetic heart valves implanted are smaller than the true aortic annulus. Both standard aortic xenografts compared in this prospectively randomized trial provide a sufficient hemodynamic and functional outcome.
BACKGROUND: To analyze the midterm clinical results after stentless mitral valve (SMV) replacement. METHODS AND RESULTS: Fifty one patients (68.3+/-8.4 years, 35 female) with severe mitral valve disease (stenosis 25, incompetence 17, mixed lesion 9) received a chordally supported SMV (Quattro, St. Jude Medical Inc.) since August 1997. Preoperative New York Heart Association class was 3.1+/-0.6; left ventricular ejection fraction 64+/-13%, and cardiac index 2.1+/-0.8 l/min/m2. Additional intraoperative ablation therapy was performed on 19 patients with chronic atrial fibrillation. Mean follow-up is 35.4+/-19.2 months (range 5 to 63). SMV implantation was performed using a conventional (32) or a minimally invasive (19) approach, valve size was 29+/-1.5 mm, cross-clamp duration was 81+/-33 minutes. Atrial rhythm was reestablished in 16 of 19 patients. Five patients required reoperation early in this series, two for paravalvular leakage, two for functional stenosis, and one with underlying rheumatoid disease. Mortality was one perioperative (1.96%, non-valve-related), one after reoperation as a result of multiple organ failure (MOF), and five during late follow-up (30+/-7 months postoperatively) for noncardiac causes. Regular echocardiographic control revealed good SMV function (Vmax 1.7+/-0.2m/s, P(mean) 3.9+/-1.2 mm Hg) and well-preserved ejection fraction postoperatively and at most recent follow-up. CONCLUSIONS: Midterm results after SMV implantation are promising. Preservation of the annuloventricular continuity leads to stable left ventricular function and combined with ablation therapy to physiological hemodynamics. Long-term durability remains to be proven.
Technical and anatomical limitations as well as human factors complicate endoscopic coronary bypass surgery. Computer-enhanced telemanipulation systems overcome some of these shortcomings by restoring the dexterity and precision of a distant operator (surgeon) within a confined space. Endoscopic coronary artery bypass grafting (CABG) has evolved from a merely experimental approach to a clinical concept. Although CABG was initially exclusively performed on the arrested heart, adjunct technologies such as endoscopic vacuum-assisted stabilizers now allow a closed-chest, beating-heart procedure. The development of anastomotic devices, and further refinements in telemanipulator technology, optical systems, and image-guided augmented-reality scenarios will greatly facilitate endoscopic bypass grafting in the future.
OBJECTIVE: Intraoperative radiofrequency ablation of atrial fibrillation (IRAAF) is a recently developed procedure being performed in an increasing number of patients. We have performed left atrial IRAAF in 387 patients since August 1998. The purpose of this article is to describe a serious complication of this procedure, namely IRAAF-induced esophageal perforation, in detail to identify possible risk factors. METHODS: Left atrial IRAAF was performed with a commercially available unipolar probe as an isolated procedure (n = 129) or in combination with mitral valve surgery (n = 163) or other surgical procedures (n = 95). Operations were performed either through a conventional sternotomy or right minithoracotomy. RESULTS: Four (1%) patients had esophageal perforation after radiofrequency ablation. All 4 patients presented after an initially unremarkable postoperative course, with sudden neurologic symptoms from esophagoatrial air embolization occurring in 3 of the patients. Three patients were successfully treated with extensive esophageal resection, and one died from massive air embolism. All perforations occurred in patients undergoing minimally invasive IRAAF. Comparison with other patients undergoing isolated minimally invasive IRAAF (n = 129) failed to reveal any reliable predictors of esophageal injury, including patient body size, operating times, or radiofrequency biophysical parameters. CONCLUSIONS: Left atrial IRAAF is associated with a small but definite risk of esophageal perforation. Unfortunately, we were unable to identify any risk factors for this life-threatening complication. A high degree of vigilance must be maintained for esophageal injury after IRAAF, particularly in patients with new neurologic deficits. Until safer methods of ablation are developed, we currently recommend against the use of IRAAF in patients undergoing cardiac surgery.
BACKGROUND: Surgical therapy for aortic stenosis leads to reverse remodeling, with normalization of left ventricular hypertrophy (LVH). The aim of this study was to examine Renin-Angiotensin system (RAS) gene expression in this setting. METHODS: Growing sheep (n=44) underwent supracoronary aortic banding for controlled induction of LVH at the age of 6 to 8 months (A=baseline). Surgical revision to completely release the pressure gradient was performed 8.3+/-1 months later (B). The animals were sacrificed after another 10.1+/-2 months (C). Along with hemodynamic measurements, subtractive hybridization and competitive polymerase chain reaction were applied to quantify mRNA expression for angiotensin-converting enzyme (ACE) and angiotensin receptors 1 and 2 (AT1-R and AT2-R). RESULTS: Left ventricular mass index was 82+/-21 g (A), 150+/-33 g (B), and 78+/-18 g (C), P<0.01. Left ventricular function and cardiac index remained stable. Myocardial fiber diameter was 11.3+/-0.8 (A), 15.9+/-1.2 (B), and 11.4+/-1 (C) microm, P<0.01. Gene expression was as follows: ACE 0.8+/-0.05 (A), 1.3+/-0.08 (B), and 0.9+/-0.06 (C), P<0.01; AT1-R 0.7+/-0.06 (A), 0.9+/-0.07 (B), and 0.3+/-0.04 (C), P<0.01; AT2-R 0.5+/-0.05 (A), 0.2+/-0.04 (B), and 0.5+/-0.05 (C), P<0.01. CONCLUSION: LVH in aortic stenosis coincides with significant alterations of the RAS. Surgical therapy leads to reverse remodeling, which is paralleled by regression of RAS gene expression.
We performed an experimental and clinical evaluation of a new low-profile bileaflet aortic valve (Regent, St. Jude Medical Inc., St. Paul, MN, U.S.A.). Common valve sizes were experimentally tested for leakage volume, pressure drop, and transvalvular hemodynamics using a pulse duplicator. Thirty patients (mean age 60 +/- 7 years, predominant valve stenosis n = 25) received the Regent prosthesis for initial clinical evaluation. In vitro evaluation revealed equivalent leakage volumes, larger performance indices (0.552 versus 0.513), and lower pressure drops in comparison to SJM hemodynamic plus valve controls. Clinically, 21 mm (n = 9), 23 mm (n = 12), and 25 mm (n = 9) valves were implanted with no significant perioperative complications. Echocardiography revealed low transvalvular flow velocities (2.2 +/- 0.4 m/s) and low pressure gradients (20 +/- 6 mm Hg) postoperatively and at 6 months follow-up. In vitro testing and early clinical results are promising; however, long-term performance has to be proven.
The purpose of this study was to evaluate the perioperative and postoperative hemodynamic function of recently introduced stentless mitral valves (SMVs). Forty-two selected patients who had received the SMV since 1997 had preoperative, postoperative, and follow-up transthoracic echocardiographic (TTE) examinations. Transesophageal echocardiography (TEE) was applied routinely during the operation as well as postoperatively if indicated. Adequate SMV function was seen in all patients perioperatively. Echocardiographic prediction of valve size and of papillary muscle distances was correct in 37 of 42 patients. Transvalvular blood flow velocities were 1.6 +/- 0.2 m/s postoperatively versus 1.8 +/- 0.3 m/s at 1 year and 1.7 +/- 0.3 m/s at 3-year follow-up. Mean transvalvular gradients were 4.3 +/- 1.6, 3.8 +/- 1.9, and 4.7 +/- 1.1 mm Hg, respectively. TEE and TTE are extremely useful to assist SMV implantation as well as for regular follow-up evaluation. The hemodynamic function after SMV implantation with preservation of the annulo-ventricular continuity is promising.