The use of MR B+1 imaging for validation of FDTD electromagnetic simulations of human anatomies.

In this study, MR B(+)(1) imaging is employed to experimentally verify the validity of FDTD simulations of electromagnetic field patterns in human anatomies. Measurements and FDTD simulations of the B(+)(1) field induced by a 3 T MR body coil in a human corpse were performed. It was found that MR B(+)(1) imaging is a sensitive method to measure the radiofrequency (RF) magnetic field inside a human anatomy with a precision of approximately 3.5%. A good correlation was found between the B(+)(1) measurements and FDTD simulations. The measured B(+)(1) pattern for a human pelvis consisted of a global, diagonal modulation pattern plus local B(+)(1) heterogeneties. It is believed that these local B(+)(1) field variations are the result of peaks in the induced electric currents, which could not be resolved by the FDTD simulations on a 5 mm(3) simulation grid. The findings from this study demonstrate that B(+)(1) imaging is a valuable experimental technique to gain more knowledge about the dielectric interaction of RF fields with the human anatomy.

Computer Simulation↗

A new robotic needle insertion method to minimise attendant prostate motion.

BACKGROUND AND PURPOSE: The purpose of this study is to investigate the efficacy of a new needle insertion method (tapping instead of pushing) in reducing attendant tissue motion. This can be useful in applications where tissue motion due to needle insertion is problematic such as e.g. MRI-guided prostate brachytherapy and breast biopsies. In this study we will focus on prostate motion due to needle insertion. MATERIAL AND METHODS: Prostate motion due to needle insertion was measured in 30 patients, who were transperineally implanted with fiducial gold markers for position verification in prostate intensity modulated radiotherapy. In total 32 needles were manually pushed into the prostate and 29 were tapped with a prototype robotic system. The prostate motion in the cranio-caudal direction was measured on the video record of the ultrasound images. Differences in prostate motion between the two needle insertion methods were analysed making use of SPSS. RESULTS: The mean prostate motion was 5.6mm (range 0.3-21.6) when the needle was pushed and 0.9 mm (range 0-2.0) when the needle was tapped into the prostate (p<0.001). CONCLUSION: Prostate motion was significantly less when the needle was tapped into the prostate compared to when the needle was pushed. This result is important for the development of a tapping, MRI-guided, prostate implant robotic system.

Biopsy↗

Towards patient specific thermal modelling of the prostate.

The application of thermal modelling for hyperthermia and thermal ablation is severely hampered by lack of information about perfusion and vasculature. However, recently, with the advent of sophisticated angiography and dynamic contrast enhanced (DCE) imaging techniques, it has become possible to image small vessels and blood perfusion bringing the ultimate goal of patient specific thermal modelling closer within reach. In this study dynamic contrast enhanced multi-slice CT imaging techniques are employed to investigate the feasibility of this concept for regional hyperthermia treatment of the prostate. The results are retrospectively compared with clinical thermometry data of a patient group from an earlier trial. Furthermore, the role of the prostate vasculature in the establishment of the prostate temperature distribution is studied. Quantitative 3D perfusion maps of the prostate were constructed for five patients using a distributed-parameter tracer kinetics model to analyse dynamic CT data. CT angiography was applied to construct a discrete vessel model of the pelvis. Additionally, a discrete vessel model of the prostate vasculature was constructed of a prostate taken from a human corpse. Three thermal modelling schemes with increasing inclusion of the patient specific physiological information were used to simulate the temperature distribution of the prostate during regional hyperthermia. Prostate perfusion was found to be heterogeneous and T3 prostate carcinomas are often characterized by a strongly elevated tumour perfusion (up to 70-80 ml 100 g(-1) min(-1)). This elevated tumour perfusion leads to 1-2 degrees C lower tumour temperatures than thermal simulations based on a homogeneous prostate perfusion. Furthermore, the comparison has shown that the simulations with the measured perfusion maps result in consistently lower prostate temperatures than clinically achieved. The simulations with the discrete vessel model indicate that significant pre-heating takes place in the prostate capsule vasculature which forms a possible explanation for the discrepancy. Pre-heating in the larger pelvic vessels is very moderate, approximately 0.1-0.3 degrees C. In conclusion, perfusion imaging provides important input for thermal modelling and can be used to obtain a lower limit on the prostate and tumour temperature in regional hyperthermia. However, it is not sufficient to calculate in detail the prostate temperature distribution in individual patients. The prostate vasculature plays such a crucial role that a patient specific discrete vessel model of the prostate vasculature is required.

Body Temperature↗

3D MR sialography protocol for postradiotherapy follow-up of the salivary duct system.

PURPOSE: To develop and evaluate an MR sialography protocol that reproducibly images the parotid and submandibular ducts over time, in 3D. Such a protocol is needed in order to investigate the possible radiation-induced changes to the salivary ducts in patients receiving radiotherapy to the head-and-neck. MATERIALS AND METHODS: MR sialography was performed on a 1.5-T MR scanner. Sequence parameters were optimized on 11 healthy volunteers. A 3D water-selective turbo spin echo (TSE) pulse sequence (TR/TE = 6000 msec/190 msec), using a two-element circular surface coil was applied twice in one MR session. In order to assess the reproducibility, the same procedure was repeated four to six months later. The quality of the MR sialograms was measured subjectively by developing a visibility scoring system and objectively by the means of contrast-to-noise ratio (CNR) of the ducts vs. fat (CNR(duct-fat)). RESULTS: High-quality, 3D MR sialographic images were obtained. The quality of the MR sialograms and the subjective visibility score of the salivary ducts were constant over time. The CNR(duct-fat) varied between volunteers (standard deviation, SD 26%) but it was relatively constant per volunteer (SD 5%). CONCLUSION: The MR sialography protocol presented in this study provides good quality 3D imaging of the major salivary ducts, submandibular duct, and the parotid duct and it can be used for the comparison of the salivary duct system of an individual over time.

Head and Neck Neoplasms↗

Measurement of prostate rotation during insertion of needles for brachytherapy.

BACKGROUND AND PURPOSE: The purpose of this study is to investigate whether prostate rotation due to needle insertion for prostate brachytherapy is predictable and if so, to quantify this rotation, and to see whether locking needles reduce the magnitude of prostate rotation. PATIENTS AND METHODS: The measurements are done at the beginning of the procedure for brachytherapy with a Foley catheter in situ. After a needle is inserted into the prostate, a 3D ultrasound scan is made. Then the seeds are delivered using RAPID Strands (Oncura), and the needle is withdrawn. A second 3D scan is made. The needle and seed positions are determined in these scans. To determine the rotation of the prostate, the angle between the needle and the seed trajectory is calculated. RESULTS: The prostate rotations have been measured in 16 patients, eight without the use of locking needles and eight with locking needles. In total 62 needles were inserted. The maximum rotation was 13.8 degrees and occurred in the coronal plane when no locking needles were used with a significant correlation (P<0.01, R=0.637) between the place of insertion and rotation. It was shown that the method (with or without locking needles) had a significant (P<0.001) influence on the rotation in the coronal plane. Rotations in the sagittal plane ranged from -8.5 degrees to +10.2 degrees without correlation with the insertion point of the needle or the use of locking needles. CONCLUSIONS: This study showed that prostate rotation during needle insertion for prostate brachytherapy is relatively large and unpredictable. Locking needles reduce prostate rotation in the coronal plane, but not in the sagittal plane. Minimising this rotation is necessary for accurate seed delivery, especially when a robotic implantation technique is used.

Brachytherapy↗

Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer.

PURPOSE: The goal of this planning study was to compare step-and-shoot intensity-modulated radiotherapy (IMRT) plans with helical dynamic IMRT plans for oropharynx patients on the basis of dose distribution. METHODS AND MATERIALS: Five patients with oropharynx cancer had been previously treated by step-and-shoot IMRT at the University Medical Centre Utrecht, The Netherlands, applying five fields and approximately 60-90 segments. Inverse planning was carried out using Plato, version 2.6.2. For each patient, an inverse IMRT plan was also made using Tomotherapy Hi-Art System, version 2.0, and using the same targets and optimization goals. Statistical analysis was performed by a paired t test. RESULTS: All tomotherapy plans compared favorably with the step-and-shoot plans regarding sparing of the organs at risk and keeping an equivalent target dose homogeneity. Tomotherapy plans in particular realized sharper dose gradients compared with the step-and-shoot plans. The mean dose to all parotid glands (n = 10) decreased on average 6.5 Gy (range, -4 to 14; p = 0.002). The theoretical reduction in normal tissue complication probabilities in favor of the tomotherapy plans depended on the parotid normal tissue complication probability model used (range, -3% to 32%). CONCLUSION: Helical tomotherapy IMRT plans realized sharper dose gradients compared with the clinically applied step-and shoot plans. They are expected to be able to reduce the parotid normal tissue complication probability further, keeping a similar target dose homogeneity.

Head and Neck Neoplasms↗

Adequate margins for random setup uncertainties in head-and-neck IMRT.

PURPOSE: To investigate the effect of random setup uncertainties on the highly conformal dose distributions produced by intensity-modulated radiotherapy (IMRT) for clinical head-and-neck cancer patients and to determine adequate margins to account for those uncertainties. METHODS AND MATERIALS: We have implemented in our clinical treatment planning system the possibility of simulating normally distributed patient setup displacements, translations, and rotations. The planning CT data of 8 patients with Stage T1-T3N0M0 oropharyngeal cancer were used. The clinical target volumes of the primary tumor (CTV(primary)) and of the lymph nodes (CTV(elective)) were expanded by 0.0, 1.5, 3.0, and 5.0 mm in all directions, creating the planning target volumes (PTVs). We performed IMRT dose calculation using our class solution for each PTV margin, resulting in the conventional static plans. Then, the system recalculated the plan for each positioning displacement derived from a normal distribution with sigma = 2 mm and sigma = 4 mm (standard deviation) for translational deviations and sigma = 1 degrees for rotational deviations. The dose distributions of the 30 fractions were summed, resulting in the actual plan. The CTV dose coverage of the actual plans was compared with that of the static plans. RESULTS: Random translational deviations of sigma = 2 mm and rotational deviations of sigma = 1 degrees did not affect the CTV(primary) volume receiving 95% of the prescribed dose (V(95)) regardless of the PTV margin used. A V(95) reduction of 3% and 1% for a 0.0-mm and 1.5-mm PTV margin, respectively, was observed for sigma = 4 mm. The V(95) of the CTV(elective) contralateral was approximately 1% and 5% lower than that of the static plan for sigma = 2 mm and sigma = 4 mm, respectively, and for PTV margins <5.0 mm. An additional reduction of 1% was observed when rotational deviations were included. The same effect was observed for the CTV(elective) ipsilateral but with smaller dose differences than those for the contralateral side. The effect of the random uncertainties on the mean dose to the parotid glands was not significant. The maximal dose to the spinal cord increased by a maximum of 3 Gy. CONCLUSIONS: The margins to account for random setup uncertainties, in our clinical IMRT solution, should be 1.5 mm and 3.0 mm in the case of sigma = 2 mm and sigma = 4 mm, respectively, for the CTV(primary). Larger margins (5.0 mm), however, should be applied to the CTV(elective), if the goal of treatment is a V(95) value of at least 99%.

Head and Neck Neoplasms↗

Experimental validation of hyperthermia SAR treatment planning using MR B1+ imaging.

In this paper the concept of using B1+ imaging as a means to validate SAR models for radiofrequency hyperthermia is presented. As in radiofrequency hyperthermia, in common clinical MR imaging which applies RF frequencies between 64 and 128 MHz, the RF field distribution inside a patient is largely determined by the dielectric distribution of the anatomy. Modern MR imaging techniques allow measurement of the RF magnetic field component B1+ making it possible to measure at high resolution the dielectric interaction of the RF field with the patient. Given these considerations, we propose to use MR imaging to verify the validity of our dielectric patient model used for SAR models of radiofrequency hyperthermia. The aim of this study was to investigate the feasibility of this concept by performing B1+ measurements and simulations on cylindrical split phantoms consisting of materials with dielectric properties similar to human tissue types. Important topics of investigation were the accuracy and sensitivity of B1+ measurements and the validity of the electric model of the MR body coil. The measurements were performed on a clinical 1.5 T MR scanner with its quadrature body coil operating at 64 MHz. It was shown that even small B1+ variations of 2 to 5% could be measured reliably in the phantom experiments. An electrical model of the transmit coil was implemented on our FDTD-based hyperthermia treatment planning platform and the RF field distributions were calculated assuming an idealized quadrature current distribution in the coil. A quantitatively good correlation between measurements and simulations was found for phantoms consisting of water and oil, while highly conductive phantoms show considerable deviations. However, assuming linear excitation for these conductive phantoms resulted in good correspondence. As an explanation it is suggested that the coil is being detuned due to the inductive nature of the conductive phantoms, breaking up the phase difference of pi/2 between the two quadrature modes. It is concluded that B1+ imaging is an accurate and sensitive method for obtaining quantitative information about the RF field in phantoms. The electrical model of the body coil is inadequate for highly conductive phantoms. It is expected that for experiments on human bodies the inductive coupling is also significant, demonstrating the need for a full resonant FDTD model of the transmit coil. This will be pursued in the near future.

Computer Simulation↗

Implanted gold markers for position verification during irradiation of head-and-neck cancers: a feasibility study.

PURPOSE: To assess the toxicity and reliability of the use of implanted gold markers for position verification during irradiation of head-and-neck cancer. METHODS AND MATERIALS: Ten patients with localized head-and-neck tumors received two gold markers in the parapharyngeal region. The acute and late radiation-related toxicity were scored prospectively using the Common Toxicity Criteria. The patients were immobilized during irradiation using a five-point mask. The marker location was detected in portal images taken with an a-Si flat panel imager. The intermarker distance, as well as the interfraction motion of the markers, was determined for all patients. RESULTS: No acute major complications were observed. The acute toxicity grade was not greater than normally detected. The markers were visible in all images. On average, the projected intermarker distance varied 0.8 mm (1 standard deviation). A small time trend was observed in the intermarker distance for 3 patients. For these patients, at least one marker was located in the mucosa or pharyngeal constrictor muscle. Deeper-seated gold markers did not show a time trend in the intermarker distance. The random positioning uncertainty determined using the markers was on average 1.1 and 1.4 mm (1 SD) in the craniocaudal and AP direction, respectively. CONCLUSION: The use of implanted gold markers for position verification during radiotherapy for head-and-neck cancer patients seems safe and feasible. To avoid any chance of migration, markers should be placed in deep muscular compartments.

Feasibility Studies↗

MRI-guided prostate brachytherapy with single needle method--a planning study.

BACKGROUND AND PURPOSE: Magnetic resonance image (MRI)-guided prostate brachytherapy with a conventional closed MR scanner is hampered by the limited access to the prostate. To handle this problem, we have designed a new implantation method, based on a patient lying in a closed MR scanner, a robotic device to be placed between patient's legs, and one needle with one insertion point. MATERIALS AND METHODS: The MRI-guided robotic system inserts the needle into the prostate to deliver the seeds. Each time, the needle will be retracted to the rotation point (in the body), and the insertion angle can be changed. The possible angles of the needle are limited by the geometry of the closed MR scanner and the presence of the symphysis, rectum and urethra. We have done a planning study to investigate the feasibility of this single needle method. RESULTS: The treatment plans made with the single needle method showed the possibility to cover the prostate with the prescribed dose without piercing the urethra or rectum and without pubic bone interference. The plans were comparable to the plans made for the multi parallel needle method, and the 144Gy isodose enclosed the prostate with a margin of about 2 mm. The planned angles of the needle were within the range of possible angles. CONCLUSIONS: This planning study has shown the feasibility of adequate prostate coverage with the divergent single needle method within the limited space inside the closed MR scanner.

Brachytherapy↗

Intrafraction motions of the larynx during radiotherapy.

PURPOSE: To quantify the intrafraction motions of the larynx during radiotherapy of laryngeal cancer. Depending on the magnitude, duration, and incidence, these motions may have clinical consequences for the choice of margins around the clinical target volume. METHODS AND MATERIALS: The intrafraction motions were analyzed for 10 patients, treated in 33 or 35 fractions. The intrafraction motions of the larynx were visualized using an a-Si flat panel imager. Images were obtained every 200 ms, resulting in a movie of images for each beam. In addition to visual analysis of all movies, the tip of the epiglottis was delineated and used as a landmark, the coordinates of which were followed in time. RESULTS: Movies were obtained during 79% of the total number of radiotherapy fractions. The total duration of swallowing was on average 0.45% (range 0.0-1.5) of the total irradiation time. Deviations of motions other than swallowing ranged between 0.3 and 11.5 mm. Some of these motions were more sudden, and others were probably related to breathing, because the frequency of these motions was 8-20/min. CONCLUSION: The incidence and total duration of swallowing is low. Therefore, it is not necessary to apply an internal margin to take into account these displacements. Other motions, however, occur more often. In 95% of the irradiation time, the tip of the epiglottis moves within a range of 7.1 mm. A margin should be applied to the clinical target volume to take into account these motions.

Deglutition↗

Segmental IMRT for oropharyngeal cancer in a clinical setting.

BACKGROUND AND PURPOSE: To develop a segmental intensity-modulated radiotherapy (IMRT) technique for the treatment of oropharyngeal cancer. PATIENTS AND METHODS: Eight patients previously treated for oropharyngeal cancer were replanned with segmental IMRT. The dose distribution was optimized using beam geometries consisting of 3, 5, 7 and 9 equiangular beams. The optimization procedure resulted in a theoretical fluence for each beam. In order to vary the number of segments, the optimized fluence was divided into four different equidistant levels. The final dose distribution was calculated using clinically deliverable segments obtained from optimized fluence. RESULTS: For our segmental IMRT technique the dose homogeneity within the target volumes improved when the total number of segments increased and reached a saturation level at approximately 150 segments. Seven beams were sufficient to achieve the saturation level for dose homogeneity. The mean dose to the parotid glands depended on the beam geometry and tumor location and did not depend on the number of segments. On average the mean dose to the contralateral parotid gland was 35.7 Gy (27.1-39.9 Gy) for all seven beam plans. CONCLUSIONS: Seven beams are sufficient to achieve an acceptable dose homogeneity within the target volumes and significant parotid sparing. These results will be used to introduce IMRT in routine clinical practice.

Humans↗

Waiting times for radiotherapy: consequences of volume increase for the TCP in oropharyngeal carcinoma.

BACKGROUND AND PURPOSE: Waiting lists for radiotherapy have become longer over the past years. Apart from the psychological distress for the patient we are concerned about tumour growth during this waiting time, which may worsen prognosis. The purpose of this pilot study was to investigate tumour growth in the waiting time and to obtain an indication of its clinical consequences for patients with oropharyngeal carcinoma. A tumour control probability (TCP) model was applied to evaluate consequences for outcome. METHODS AND MATERIALS: Increase in tumour volume was measured for 13 patients with oropharyngeal carcinoma by outlining the tumour on the diagnostic as well as on the treatment planning CT scan. Waiting time was defined as time between histopathological diagnosis and start of radiotherapy. For each tumour we calculated the increase in tumour volume and the tumour doubling time. The potential increase in TCP was calculated for each tumour for the situation without treatment delay. RESULTS: The mean increase in tumour volume was 70%. The mean waiting time was 56 days. Expected TCP with incorporation of delay was 47%, without delay it might have been 63-66%. CONCLUSION: This study shows tumour progression during the time between the diagnostic CT scan and the treatment planning CT scan in oropharyngeal cancer. As a consequence of waiting time, which allows tumour volume increase, there may be an average control loss of 16-19 % for these tumours during the total waiting time before radiotherapy.

Aged↗

Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation.

BACKGROUND AND PURPOSE: The aim of this study was to assess the feasibility of using gold seed implants in the prostate for position verification, using an a-Si flat panel imager as a detector during megavoltage irradiation of prostate carcinoma. This is a study to guarantee positioning accuracy in intensity-modulated radiotherapy. METHODS AND MATERIALS: Ten patients with localized prostate carcinoma (T2-3) received between one and three fiducial gold markers in the prostate. All patients were treated with 3-D conformal radiotherapy with an anterior-posterior (AP) and two lateral wedge fields. The acute gastrointestinal (GI) and genitourinary (GU) toxicities were scored using common toxicity criteria scales (CTC). Using three consecutive CT scans and portal images obtained during the treatment we have studied the occurrence of any change in prostate shape (deformation), seed migration and the magnitude of translations and rotations of the prostate. RESULTS: We observed no acute major complications for prostate irradiation regarding the seed implantation. The maximum acute GU toxicity grade 2 (dysuria and frequency) was observed in seven patients during the treatment. The maximum grade 2 (diarrhoea) was scored in two patients regarding the acute GI toxicities. No significant prostate deformation could be detected in the consecutive CT scans. It appeared that the distances between the markers only slightly changed during treatment (S.D. 0.5 mm). Random prostate translations were (1 S.D.) 2.1, 3.2 and 2.2 mm in the lateral (LR), AP and cranial-caudal (CC) directions, respectively, whereas systematic translations were 3.3, 4.8 and 3.5 mm in the LR, AP and CC directions, respectively. Random prostate rotations were (1 S.D.) 3.6, 1.7 and 1.9 degrees around the LR, AP and CC axis, respectively, whereas systematic rotations were 4.7, 2.0 and 2.7 degrees around the LR, AP and CC axis, respectively. CONCLUSIONS: We found that the fiducial gold seeds are a safe and appropriate device to verify and correct the position of prostate during megavoltage irradiation. The amount of seed migration and prostate deformation is far below our present tumour delineation accuracy.

Aged↗

Comparison of megavoltage position verification for prostate irradiation based on bony anatomy and implanted fiducials.

PURPOSE: The patient position during radiotherapy treatment of prostate cancer can be verified with the help of portal images acquired during treatment. In this study we quantify the clinical consequences of the use of image-based verification based on the bony anatomy and the prostate target itself. PATIENTS AND METHODS: We analysed 2025 portal images and 23 computed tomography (CT) scans from 23 patients with prostate cancer. In all patients gold markers were implanted prior to CT scanning. Statistical data for both random and systematic errors were calculated for displacements of bones and markers and we investigated the effectiveness of an off-line correction protocol. RESULTS: Standard deviations for systematic marker displacement are 2.4 mm in the lateral (LR) direction, 4.4 mm in the anterior-posterior (AP) direction and 3.7 mm in the caudal-cranial direction (CC). Application of off-line position verification based on the marker positions results in a shrinkage of the systematic error to well below 1 mm. Position verification based on the bony anatomy reduces the systematic target uncertainty to 50% in the AP direction and in the LR direction. No reduction was observed in the CC direction. For six out of 23 patients we found an increase of the systematic error after application of bony anatomy-based position verification. CONCLUSIONS: We show that even if correction based on the bony anatomy is applied, considerable margins have to be set to account for organ motion. Our study highlights that for individual patients the systematic error can increase after application of bony anatomy-based position verification, whereas the population standard deviation will decrease. Off-line target-based position verification effectively reduces the systematic error to well below 1 mm, thus enabling significant margin reduction.

Cluster Analysis↗

Measurements and clinical consequences of prostate motion during a radiotherapy fraction.

PURPOSE: Here we study the magnitude of prostate motion during the delivery of a radiotherapy fraction. These motions have clinical consequences for on-line position verification and the choice of margins around the target volume. METHODS AND MATERIALS: We studied the motion of the prostate for 10 patients during 251 radiotherapy treatment fractions by assessing the position of implanted gold markers. Gold markers of 1 mm diameter and 5 mm length were implanted in the prostate before the start of the radiotherapy. We obtained movies during each fraction using an a-Si flat-panel imager. The markers could be detected in separate frames using a marker extraction kernel. RESULTS: Marker displacements as large as 9.5 mm were detected in one fraction. The motion of the prostate is greatest in the caudal-cranial and the anterior-posterior directions. Within a time window of 2 to 3 min, deviations from the initial marker position, averaged over all patients, are 0.3 +/- 0.5 mm and -0.4 +/- 0.7 mm in the anterior-posterior and caudal-cranial directions, respectively. CONCLUSIONS: It appeared that on average, the intrafraction prostate motions did not result in margins larger than 1 mm, provided that the position verification is performed at time intervals of 2 to 3 min. Only for some patients performing more frequent position verification or adding extra margins of 2 to 3 mm is required to account for intrafraction prostate motions.

Dose Fractionation, Radiation↗

Three-dimensional controlled interstitial hyperthermia combined with radiotherapy for locally advanced prostate carcinoma--a feasibility study.

PURPOSE: To perform a feasibility study of three-dimensional spatially controlled interstitial hyperthermia for locally advanced prostate cancer. METHODS AND MATERIALS: Twelve patients with prostate cancer (T3NxM0) were treated with conventional external beam radiotherapy and one interstitial hyperthermia treatment. Hyperthermia was delivered with the 27-MHz multielectrode current source (MECS) interstitial hyperthermia technique on an outpatient basis. Guided by transrectal ultrasonography, 12 catheters (range 7-16) were placed in the prostate through a template. Two electrodes per probe were inserted. Thermometry (average 100 sensors) was performed from within the probes for online temperature control. Additional thermometry was done in the prostate, rectum, urethra, and bladder. Reconstruction was done by sonography. Prostate perfusion was estimated from the thermal decay at the end of treatment. The full three-dimensional temperature distribution was calculated. RESULTS: No toxicities greater than Grade 2 were recorded. A learning curve for implantation, position verification, reconstruction, and temperature simulation was experienced. Perfusion was 47 mL/100 g/min (range 30-65). The average measured temperature was T(90) (90% of the prostate reached a temperature of at least:) 39.9 degrees C and T(50) 44.1 degrees C. The average calculated temperatures were lower: T(90), 39.4 degrees C and T(50), 41.8 degrees C, because the entire prostate was taken into account. The tumor temperatures were T(90), 40.7 degrees C and T(50), 43.0 degrees C. The bladder and rectal temperatures were below the safety limits. CONCLUSION: Multielectrode-current-source interstitial hyperthermia is technically feasible and well tolerated. It was not possible to achieve the goal temperature of 42-43 degrees C because of high perfusion and implantation limitations.

Aged↗

Prostate perfusion in patients with locally advanced prostate carcinoma treated with different hyperthermia techniques.

PURPOSE: We determined prostate perfusion in 18 patients with locally advanced prostate carcinoma treated with a combination of external beam irradiation and regional (10) or interstitial (8) hyperthermia. MATERIALS AND METHODS: Perfusion values were calculated from temperature elevations due to constant applied power and from transient temperature measurements after a change in applied power. Student's t test was used for comparing perfusion values with time and in the 2 groups. RESULTS: At the start of regional hyperthermia treatment mean estimated perfusion plus or minus standard deviation was 10 +/- 8 ml./100 gm. per minute. At the end of treatment mean perfusion was increased to 14 +/- 2 ml./100 gm. per minute (p <0.01). Achieved thermal parameters were a mean temperature of at least 40.3C +/- 0.6C in 90% of the prostate, 40.9C +/- 0.6C in 50% and a mean maximum temperature of 41.6C +/- 0.6C. At the end of interstitial hyperthermia treatment estimated mean perfusion was 47 +/- 5 ml./100 gm. per minute, which was significantly different compared with the end of regional hyperthermia (p < 0(-7) ). Mean temperature was at least 39.4C +/- 0.9C in 90% of the prostate and 41.8C +/- 1.6C in 50%, while mean maximum temperature was 53.1C +/- 6.3C. Systemic temperature increased during regional hyperthermia up to 38.6C, whereas during interstitial hyperthermia body temperature was not elevated. CONCLUSIONS: During interstitial hyperthermia perfusion values are higher than during regional hyperthermia. Hyperthermia causes increased prostate perfusion.

Aged↗