PubMed Health⌕ Search

Biomedical subjects

Jan Kaminsky

Publications and source records attributed to Jan Kaminsky.

6 recordsLinked to original sources

The impact of petrosal vein preservation on postoperative auditory function in surgery of petrous apex meningiomas.

OBJECTIVE: The importance of preserving the superior petrosal vein has received increasing attention in the surgical treatment of pathologies involving the petrous apex. Recent reports have associated postoperative auditory nerve dysfunction with petrosal vein sacrifice. However, there is no systematic clinical study available thus far focusing on the postoperative auditory function after petrosal vein obliteration. METHODS: In 55 patients with meningiomas involving the petrous apex, pre- and intraoperative findings including petrosal vein sectioning were analyzed retrospectively concerning their impact on postoperative auditory function. RESULTS: The petrosal vein was preserved in 26 (47%) cases. In 27 (49%) cases, this vein was not preserved. Hearing loss occurred in 11% of all cases. In the preserved-vein group, postoperative hearing loss occurred in 3 of 26 (11%) cases and in the sacrificed-vein group in 3 of 27 (11%) cases. CONCLUSION: Sacrifice of the petrosal vein during surgery of petrous apex meningiomas seems not to have an impact on postoperative auditory function.

Adult↗

The impact of hypotension due to the trigeminocardiac reflex on auditory function in vestibular schwannoma surgery.

OBJECT: Surgical manipulation of the fifth cranial nerve during its intra- or extracranial course may lead to bradycardia or even asystole as well as arterial hypotension, a phenomenon described as the trigeminocardiac reflex (TCR). The authors studied the impact of this reflex on postoperative auditory function in patients undergoing vestibular schwannoma (VS) surgery. METHODS: One hundred patients scheduled for VS surgery were studied prospectively for parameters influencing the postoperative auditory function. The evaluation included sex, age, pre- and postoperative auditory function, preoperative mean arterial blood pressure, preoperative medical diseases or medication (for example, antiarrhythmia drugs), tumor size and localization, and the intraoperative occurrence of the TCR. The TCR, which occurred in 11% of the patients, influenced the postoperative hearing function in the patients with Hannover Class T3 and T4 VSs. With an overall hearing preservation of 47%, 11.1% of the patients in the TCR group and 51.4% of those in the non-TCR group experienced preserved hearing function postoperatively. In cases involving larger tumors (Hannover Class T3 and T4), an intraoperative TCR was associated with a significantly worse postoperative hearing function during VS surgery (p = 0.005). CONCLUSIONS: The hypotension following TCR is a negative prognostic factor for hearing preservation in patients undergoing VS surgery. Patients' knowledge of this can be increased pre- and postoperatively. Further study of this phenomenon will advance the understanding of the underlying mechanisms and may help to improve hearing preservation by controlling the occurrence of the TCR.

Adolescent↗

Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI.

INTRODUCTION: 3-Tesla (T) magnetic resonance imaging (MRI) offers high resolution imaging with improved signal quality. It also allows for improved functional investigations, most prominently with respect to fiber tracts and their relation to pathological lesions. Up to now, patients with adjustable shunt systems were not eligible for high field power magnetic resonance imaging. We have evaluated the effects of this technique upon a newly developed adjustable shunt valve. METHOD: Ten adjustable shunt devices were examined during routine and functional 3-T high field MRI examinations. Pressure settings were checked after 17 examinations each for all valves. There were no changes in pressure setting at all possible levels in any of the tested devices. No problems with the adjusting mechanism were observed during 340 examinations. CONCLUSION: This new shunt device offers the diagnostic benefit of high field magnetic resonance imaging in shunt-dependent patients who need an adjustable valve. The valve is not affected by higher magnetic field power and does not require readjustment of the pressure settings after MRI examination.

Brain Diseases↗

A universal algorithm for an improved finite element mesh generation Mesh quality assessment in comparison to former automated mesh-generators and an analytic model.

The FE-modeling of complex anatomical structures is not solved satisfyingly so far. Voxel-based as opposed to contour-based algorithms allow an automated mesh generation based on the image data. Nonetheless their geometric precision is limited. We developed an automated mesh-generator that combines the advantages of voxel-based generation with improved representation of the geometry by displacement of nodes on the object-surface. Models of an artificial 3D-pipe-section and a skullbase were generated with different mesh-densities using the newly developed geometric, unsmoothed and smoothed voxel generators. Compared to the analytic calculation of the 3D-pipe-section model the normalized RMS error of the surface stress was 0.173-0.647 for the unsmoothed voxel models, 0.111-0.616 for the smoothed voxel models with small volume error and 0.126-0.273 for the geometric models. The highest element-energy error as a criterion for the mesh quality was 2.61x10(-2) N mm, 2.46x10(-2) N mm and 1.81x10(-2) N mm for unsmoothed, smoothed and geometric voxel models, respectively. The geometric model of the 3D-skullbase resulted in the lowest element-energy error and volume error. This algorithm also allowed the best representation of anatomical details. The presented geometric mesh-generator is universally applicable and allows an automated and accurate modeling by combining the advantages of the voxel-technique and of improved surface-modeling.

Algorithms↗

Nausea and dizziness after vestibular schwannoma surgery: a multivariate analysis of preoperative symptoms.

OBJECTIVE: Nausea and dizziness are very discomforting for patients after vestibular schwannoma surgery and they impair recovery. METHODS: To identify preoperative symptoms and conditions that increase the risk of development of nausea after vestibular schwannoma surgery, a multivariate analysis was performed. One hundred fifteen patients with vestibular schwannoma had a microsurgical tumor removal in a standardized procedure in 2001 and 2002. Eighteen patients were excluded from the study because of previous surgery (recurrent tumors, 7 patients) or bilateral tumor occurrence (neurofibromatosis, 11 patients). Analysis was performed regarding postoperative amount of antiemetic medication, vomiting, and subjective feeling of the patient. Tumor grading, body mass index, sex, previous complaints, examination at admission, and side of the tumor were taken in consideration. RESULTS: Women had significant longer postoperative complaints (mean, 3.0 d; standard error, 0.47) and needed longer antiemetic therapy (mean, 3.3 d; standard error, 0.49) than men (mean, 1.72 d; standard error, 0.21). Patients developing no significant postoperative complaints were all in the higher tumor grading group, Grades 3a, 4a, and 4b. There was a significant difference in the duration of antiemetic therapy between tumors graded 1 and tumors graded 3 or 4. Patients with a positive stepping test preoperatively had a tendency to demand less antiemetic medication. Women with small tumors are most likely to develop significant complaints after vestibular schwannoma surgery. CONCLUSION: It is possible to identify patients with a higher risk of postoperative nausea and dizziness after vestibular schwannoma surgery. This allows one to inform these patients preoperatively and to initiate an early postoperative drug therapy to ease their symptoms.

Adult↗

Specially adapted interactive tools for an improved 3D-segmentation of the spine.

For imaging purposes of the spine, segmented image data provides the basis for a variety of modern clinical applications. However, the anatomical complex structure of the spine as well as the extensive degenerative bony deformations apparent in the clinical situation, generally complicate the application of a fully automated segmentation. To serve the special needs for image segmentation of the spine anatomy a newly developed software system is presented, that implements specially adapted interactive tools, taking its 'axis'-skeletal structure into account. A standardized protocol combines the newly developed interactive tools (rotation transformation, warped dissection plane) with standard segmentation tools to provide both a fast and accurate segmentation procedure. The introduced software environment has been valuable for the segmentation of cervical, thoracic and lumbar spines segments based on clinical routine and research images.

Computers↗