PubMed Health⌕ Search

Biomedical subjects

Jan Preisler

Publications and source records attributed to Jan Preisler.

5 recordsLinked to original sources

Structural protein analysis of the polyvalent staphylococcal bacteriophage 812.

Phage 812 is a polyvalent phage with a very broad host range in the genus Staphylococcus, which makes it a suitable candidate for phage therapy of staphylococcal infections. This proteomic study, combining the results of both 1-DE and 2-DE followed by PMF, led to the identification of 24 virion proteins. Twenty new proteins, not yet identified by proteome analysis of closely related staphylococcal phages K and G1 were identified using this approach. Fifteen proteins were assigned unambiguously to the head-tail genome module; the remaining nine proteins are encoded by genes of the left or right arms of the phage genome. As expected, the most abundant proteins in the electrophoretic patterns are the major capsid protein, the major tail sheath protein and proteins identical to ORF 50 and ORF 95 of phage K, although their function is only putative. Identification of these 20 new proteins contributes substantially to a detailed characterization of phage virions, knowledge of which is necessary for rational phage therapy.

Electrophoresis, Polyacrylamide Gel↗

Sensitive determination of erythrosine and other red food colorants using capillary electrophoresis with laser-induced fluorescence detection.

Capillary electrophoresis with laser-induced fluorescence detection (CE-LIF) was applied to separation and sensitive determination of red food colorants. Diode pumped frequency-doubled Nd:YAG laser (532 nm) was used as an excitation source in a laboratory-built CE-LIF system. For highly fluorescent erythrosine B (E127), an extrapolated limit of detection (LOD) of 0.4 ng mL(-1) (S/N=3) was achieved. Extrapolated LODs of other tested red additives, such as carmoisine, E122 (0.5 microg mL(-1)); amaranth, E123 (0.2 microg mL(-1)); ponceau 4R, E124 (0.3 microg mL(-1)) and red 2G, E128 (0.3 microg mL(-1)) were about one-order lower compared to results obtained with CE with absorbance detection in UV/vis (CE-UV/vis). The main advantages of using CE-LIF for analysis of food samples are high selectivity and minimization of matrix effect. To our knowledge, this is the first use of CE-LIF for determination of red food colorants.

Coloring Agents↗

Capillary array electrophoresis-MALDI mass spectrometry using a vacuum deposition interface.

We previously introduced a vacuum deposition interface for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF MS) on a moving surface (e.g., quartz wheel, Mylar tape, metal target). In our present work, the approach has been extended to demonstrate parallel analysis for multiple on-line infusion MALDI MS and capillary array electrophoresis (CAE)-MALDI MS. In the infusion mode, individual peptide samples were simultaneously deposited on a Mylar tape cartridge using an array of eight capillaries, yielding eight parallel traces. For CAE-MALDI/TOF MS, the same number of separation capillaries were coupled with an array of eight infusion capillaries using a common liquid junction, containing matrix solution. A fast-scanning mirror was employed to traverse the beam of the desorption laser across the Mylar tape to probe one trace at a time. The positions of the eight sample traces formed on the tape were automatically determined, and all samples were analyzed in rapid sequence using a kilohertz repetition rate laser and a high-throughput data acquisition system. The instrumentation was operated with CAE MS for high-throughput analysis without compromising data quality. The principles of parallel separation-vacuum deposition should be generally applicable to MALDI/TOF MS analysis for proteomics and other areas where separation and high throughput are required.

Angiotensins↗

Off-line coupling of high-resolution capillary electrophoresis to MALDI-TOF and TOF/TOF MS.

High-resolution capillary electrophoresis has been coupled to MALDI-TOF and TOF/TOF MS through off-line vacuum deposition onto standard stainless steel MALDI targets. This off-line approach allowed the decoupling of the separation from the MS analysis, thus allowing each to be independently optimized in terms of time. Using BSA tryptic digest as a model sample, the deposited streaks, roughly 100-microm wide, were first analyzed in the MS mode, consuming only a fraction of the sample. After data analysis, segments of the deposited trace, containing unidentified peptides, as well as several species chosen for sequence confirmation, were reanalyzed in the MS/MS mode using MALDI-TOF/TOF MS. Additionally, it is shown that the shot-to-shot reproducibility of the vacuum-deposited trace (5% RSD) is 1 order of magnitude lower than that found for the standard dried droplet method. Moreover, a linear dependence of signal intensities (relative to an internal standard) over 3 orders of magnitude was found for a peptide sample with concentrations ranging from 1 to 1000 nM. This paper demonstrates the potential of off-line coupling of high-resolution separations to MALDI-MS and MALDI-MS/MS using vacuum deposition for the analysis of complex peptide mixtures from protein digests.

Electrophoresis, Capillary↗