Jan S Bauer

Publications and source records attributed to Jan S Bauer.

6 recordsLinked to original sources

Cell labeling with the positive MR contrast agent Gadofluorine M.

The purpose of this study was to label human monocytes with Gadofluorine M by simple incubation for subsequent cell depiction at 1.5 and 3 T. Gadofluorine M displays a high r(1) relaxivity and is spontaneously phagocytosed by macrophages. Human monocytes were incubated with Gadofluorine M-Cy at varying concentrations and incubation times and underwent MR imaging at 1.5 and 3 T at increasing time intervals after the labeling procedure. R1-relaxation rates and r1 relaxivities of the labeled cells and non-labeled controls were determined. Cellular contrast agent uptake was examined by fluorescence microscopy and quantified by ICP-AES. Efficient cell labeling was achieved after incubation of the cells with 25 mM Gd Gadofluorine M for 12 h, resulting in a maximal uptake of 0.3 fmol Gd/cell without impairment of cell viability. Fluorescence microscopy confirmed internalization of the fluorescent contrast agent by monocytes. The r1 relaxivity of the labeled cells was 137 mM(-1)s(-1) at 1.5 T and 80.46 mM(-1)s(-1) at 3 T. Imaging studies showed stable labeling for at least 7 days. Human monocytes can be effectively labeled for MR imaging with Gadofluorine M. Potential in vivo cell-tracking applications include targeting of inflammatory processes with Gadofluorine-labeled leukocytes or monitoring of stem cell therapies for the treatment of arthritis.

Cells, Cultured↗

MR imaging of the ankle at 3 Tesla and 1.5 Tesla: protocol optimization and application to cartilage, ligament and tendon pathology in cadaver specimens.

The objective of this study was to optimize ankle joint MR imaging in volunteers at 1.5 Tesla (T) and 3.0 T, and to compare these optimized sequences concerning image quality and performance in assessing cartilage, ligament and tendon pathology in fresh human cadaver specimens. Initially our clinical ankle protocol consisting of T1-weighted (-w), fat-saturated (fs) T2-w, and short tau inversion-recovery fast spinecho (FSE) sequences was optimized at 1.5 T and 3.0 T by two radiologists. For dedicated cartilage imaging, fs-intermediate (IM)-w FSE, fs spoiled gradient echo, and balanced free-precession steady-state sequences were optimized. Using the optimized sequences, thirteen cadaver ankle joints were imaged. Four radiologists independently assessed these images concerning image quality and pathology. All radiologists consistently rated image quality higher at 3.0 T (all sequences p<0.05). For detecting cartilage pathology, diagnostic performance was significantly higher at 3.0 T (ROC-values up to 0.93 vs. 0.77; p<0.05); the fs-IM FSE sequence showed highest values among the different sequences. Average sensitivity for detecting tendon pathology was 63% at 3.0 T vs. 41% at 1.5 T and was significantly higher at 3.0 T for 2 out of 4 radiologists (p<0.05). Compared to 1.5 T, imaging of the ankle joint at 3.0 T significantly improved image quality and diagnostic performance in assessing cartilage pathology.

Aged↗

Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

PURPOSE: To investigate in vitro the calcaneal trabecular bone structure in elderly human donors with high spatial resolution magnetic resonance (MR) imaging at 3.0 T and 1.5 T, to quantitatively compare MR measures of bone microarchitecture with those from micro-computed tomography (CT), and to compare the performance of 3.0-T MR imaging with that of 1.5-T MR imaging in differentiating donors with spinal fractures from those without spinal fractures. MATERIALS AND METHODS: The study was performed in line with institutional and legislative requirements; all donors had dedicated their body for educational and research purposes prior to death. Sagittal MR images of 49 human calcaneus cadaveric specimens were obtained (mean age of donors, 79.5 years +/- 11 [standard deviation]; 26 male donors, 23 female donors). After the spatial coregistering of images acquired at 3.0-T and 1.5-T MR imaging, the signal-to-noise-ratios and structural parameters obtained at each magnetic field strength were compared in corresponding sections. Micro-CT was performed on calcaneus cores obtained from corresponding regions in 40 cadaveric specimens. Vertebral deformities of the thoracic and lumbar spine were radiographically classified by using the spinal fracture index. Diagnostic performance of the structural parameters in differentiating donors with vertebral fractures from those without was assessed by using receiver operator characteristic (ROC) analysis, including area under the ROC curve (A(z)). RESULTS: Correlations between structural parameters at 3.0-T MR imaging and those at micro-CT were significantly higher (P < .05) than correlations between structural parameters at 1.5-T MR imaging and those at micro-CT (trabecular thickness, r = 0.76 at 3.0 T vs r = 0.57 at 1.5 T). Trabecular dimensions were amplified at 3.0 T because of increasing susceptibility artifacts. Also, higher ROC values were found for structural parameters at 3.0 T than at 1.5 T, but differences were not significant (trabecular thickness, A(z) = 0.75 at 3.0 T vs A(z) = 0.66 at 1.5 T, P > .05). CONCLUSION: MR imaging at 3.0 T provided a better measure of the trabecular bone structure than did MR imaging at 1.5 T. There was a trend for better differentiation of donors with from those without osteoporotic vertebral fractures at 3.0 T than at 1.5 T.

Aged↗

Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.

PURPOSE: To compare the precision and accuracy of 3.0-T and 1.5-T magnetic resonance (MR) imaging in the quantification of cartilage volume by using direct volumetric measurements as a reference standard. MATERIALS AND METHODS: The local animal experimentation committee did not require its approval for this study. Porcine knees were obtained from an abattoir. These specimens were used to optimize imaging parameters regarding effective signal-to-noise ratio (SNRE) and contrast-to-noise ratio (CNRE) for a fat-saturated spoiled gradient-recalled acquisition in the steady state (SPGR) sequence, a water excitation SPGR sequence, and a fast spin-echo sequence at 3.0 T and a fat-saturated SPGR sequence at 1.5 T. By using the optimized sequences, 18 specimens were imaged in less than 6 minutes per sequence. A fivefold repetition of measurements of four specimens was performed for precision analysis. Cartilage was segmented by using semiautomatic software to calculate the volume. After imaging, the cartilage was scraped off and the volume was measured directly by using a saline-displacement method to calculate accuracy. Precision and accuracy errors were calculated as the root-mean-squares of the single errors per specimen. RESULTS: SNRE and CNRE values, respectively, were highest for the water excitation sequence at 3.0 T (1.81 sec(-1/2) and 1.27 sec(-1/2)), followed by the fat-saturated SPGR sequence (1.52 sec(-1/2) and 1.07 sec(-1/2)). The fast spin-echo sequence and the fat-saturated SPGR sequence at 1.5 T had lower SNR(E) (1.27 sec(-1/2) and 0.59 sec(-1/2), respectively). Accuracy error for MR-based volume calculation at the femur was 5.0%, 3.0%, 21%, and 16% for the water excitation, fat-saturated SPGR, and fast spin-echo sequences at 3.0 T and the fat-saturated SPGR sequence at 1.5 T, respectively. CONCLUSION: MR imaging at 3.0 T was shown in our study to better quantify cartilage volume. SNRE and CNRE were substantially improved, resulting in significantly higher accuracy in determining cartilage volume.

Animals↗

Imaging of trabecular bone structure.

In addition to bone mass, trabecular bone architecture is an important entity in assessing bone fragility, which is crucial in the diagnosis of osteoporosis. A number of imaging techniques have been used to analyze bone structure noninvasively. Projection radiography has been used with good results in the peripheral skeleton; however, this is only a two-dimensional technique, which reflects trabecular bone structure to a certain extent. High-resolution tomographic techniques, such as high-resolution magnetic resonance imaging and computed tomography (CT), have a limited spatial resolution but the potential to image three-dimensional architecture of trabecular bone. With the advances in magnetic resonance hardware and software and new CT techniques (i.e., multislice spiral CT and clinical micro-CT), noninvasive imaging of trabecular bone is becoming more feasible.

Bone and Bones↗

Trabecular bone structure obtained from multislice spiral computed tomography of the calcaneus predicts osteoporotic vertebral deformities.

PURPOSE: To compare multislice computed tomography (MSCT)-derived parameters of the trabecular bone structure of the calcaneus with bone mineral density (BMD) in their ability to differentiate between donors with and without osteoporotic fractures of the spine and to optimize CT scan protocols. METHODS: Forty-two postmortem calcanei (81.2 +/- 10 years) were imaged with a 16-detector row MSCT system using 4 different scan protocols varying spatial resolution (12-24 lp/cm) and radiation dose. Structural parameters of trabecular bone were derived from these images, and BMDs of the calcanei were determined using dual x-ray absorptiometry. Vertebral deformities of the spine were radiographically classified using the Spinal Fracture Index. Diagnostic performance in differentiation between donors with and without vertebral fractures was assessed using receiver operating characteristic (ROC) analysis. RESULTS: There were significant case-control differences for many of the structural parameters measured (P < 0.05). The highest ROC values were found for apparent trabecular thickness using the high-resolution and high-dose protocols. Statistically significant correlations were found between most structure parameters and BMD (up to r = 0.85, P < 0.01). CONCLUSION: Structural parameters of trabecular bone as obtained from high-resolution MSCT images of the calcaneus can be used to differentiate between donors with and without osteoporotic vertebral fractures, using a high-resolution and high-dose CT protocol.

Absorptiometry, Photon↗