PubMed Health⌕ Search

Biomedical subjects

Jan Schmitt

Publications and source records attributed to Jan Schmitt.

8 recordsLinked to original sources

Femoral strain changes after total hip arthroplasty--patient-specific finite element analyses 12 years after operation.

Periprosthetic stress-shielding after total hip arthroplasty (THA) is a well-known phenomenon. Many authors have used the finite element (FE) method to show the effects of THA on animal or human femora. In most cases they have performed cadaver experiments. The current project is a FE analysis based on a retrospective computerized tomography (CT) in vivo data set of 11 patients 12 years after THA. In order to control the analysis, a computationally created stem was implanted at the femur model of the not operated contralateral side. In comparison to the not operated side, there was a significant reduction of the strain energy density (SED) values in all regions of interest (ROI) with the greatest effect near the distal tip of the stem. Only zone 1 showed no clear trend which may be due to load application at the greater trochanter causing local strain peaks. The median SED values changed by -31.65% (ROI 1), -25.64% (ROI 2), -30.82% (ROI 3), -12.35% (ROI 4), -40.10% (ROI 5), -30.37% (ROI 6) and -43.38% (ROI 7). As far as we are aware, the current combination of in vivo CT density data with FE strain analyses after THA is based on the largest number of patients and the longest follow-up period. This combination enables analysis and prediction of the influence of implantation upon bone and can be compared with of remodelling theories. The assessment of mechanical strain data during a follow-up trial could be a new approach for analyzing different hip stems in clinical biomechanics.

Adult↗

Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study.

While static MRI of the TMJ is the method of choice to evaluate the articular disk (AD), dynamic MRI so far has failed to display the AD. The capability of a modified True-FISP sequence to visualize the AD in dynamic near-real-time imaging (NRTI) was evaluated. Twelve healthy subjects and 17 patients were investigated. Besides static routine imaging, sagittal NRTI of both TMJs was performed with a True-FISP sequence at 1.5 T with TE/TR=1.84/3.68 ms. Two temporal resolutions (250/500 ms) were tested. The quality of the visualization of the AD was rated on a four-point scale (1= very good to 4= poor visualization) by two observers in consensus. ADs of the volunteers were visualized with high quality in all stages of movement (score: 1.69). In patients with internal derangement, disk-motion was clearly depicted, including fast reposition movements. Due to degenerative changes of the AD, the quality of the depiction in patients was slightly lower (score: 2.4). According to the preliminary results of this feasibility study, the suggested NRTI True-FISP sequence is capable of visualizing the entire motion of the AD of the TMJ in normal and pathologic stages with high quality. Further studies are needed to prove the clinical usefulness of this new technique.

Computer Systems↗

MR imaging of lung parenchyma at 0.2 T: evaluation of imaging techniques, comparative study with chest radiography and interobserver analysis.

The purpose of this study was to evaluate low-field MR imaging of the lung parenchyma in comparison with postero-anterior (PA) and lateral chest radiographs (CR). One hundred one prospectively randomized patients who had received routine CR were additionally examined with magnetic resonance imaging (MRI) at 0.2 T. Utilized sequences were: constructive interference in steady state (CISS), true fast imaging in steady state precession (True-FISP) and T1-weighted spin-echo (T1SE). Consensus reading of two observers was performed for CR. Three other observers analyzed hardcopies of the MRI examinations for each sequence independently. The individual results for the comparisons between the sequences and CR were calculated using kappa coefficients with their corresponding confidence intervals. Additionally, an interobserver analysis was performed. The proportions of agreement for the three sequences compared with CR were high, with 0.93 for CISS, 0.89 for True-FISP and 0.91 for T1SE. The kappa coefficients and the corresponding confidence intervals were 0.81 [0.68; 0.95] for CISS, 0.72 [0.57; 0.88] for True-FISP and 0.78 [0.65; 0.92] for T1SE. Concerning CISS, differences between MRI and CR were mainly related to advantages resulting from cross-sectional imaging. The smallest 95% lower confidence bound of the three kappa measures for comparing the MR readers with each other was 0.97, indicating a high interobserver agreement. Low-field MRI of the lung parenchyma using the CISS sequence is well comparable with chest radiography and demonstrates slight advantages resulting from the cross-sectional imaging technique.

Adult↗

[The effectiveness of radiation treatment in comparison with extracorporeal shockwave therapy (ESWT) in supraspinatus tendon syndrome].

BACKGROUND AND AIM: Supraspinatus tendinitis is usually treated by antiinflammatoric drugs, local injections, physiotherapy or low-dose irradiation. A novel approach is the use of Extracorporeal Shock Wave Therapy (ESWT) if conservative therapies have failed. So far there has been no controlled study comparing the effectiveness of ESWT with an established conservative method of therapy such as X-ray stimulation radiotherapy. PATIENTS AND METHOD: 30 patients with chronic supraspinatus tendinitis were admitted into the prospective randomized study. After randomization the patients were treated either with X-ray stimulation radiotherapy with 6 x 0.5 Gy on the ICRU reference point (1 fraction/day) with cobalt 60 gamma rays or three times with 2000 pulses (energy flux density ED+ 0.1 mJ/mm2) in 1 week intervals using a Storz Minilith SL1. Primary endpoint was the age-corrected constant score 3 months after intervention. RESULTS: Acute side effects caused by the irradiation were not observed, as expected. One patient described pain and one patient showed a moderate skin irritation after ESWT. In the radiotherapy group average the age-corrected constant score improved from 47.6 through 79.5 points to 87.4 points. In the ESWT group it rose from 50.1 points before ESWT to 91.4 points after 12 weeks and 97.8 after 52 weeks. CONCLUSION: No statistically significant differences were proven between ESWT and radiotherapy. ESWT appears to be equivalent but not superior to radiotherapy in treating chronic supraspinatus tendinitis syndrome. A comprehensive randomized study is, however, necessary to ensure the equivalence of ESWT.

Adult↗

Validation data for periprosthetic bone remodelling theories.

Periprosthetic adaptive bone remodelling after total hip arthroplasty (THA) has been frequently simulated in computer models, combining bone remodelling theory with finite element analysis. Unfortunately, there still subsist a lack of clinical data, which are necessary for validation of these simulation results. Therefore, the objective of the current project is to collect prospective volumetric bone density data with a clinical computerized tomography study in seven patients after THA. A retrospective study 12 years after implantation in 11 patients was added. A data set of about 100000 bone voxels for each femur was collected. In all prospective cases, the predominant change is seen during the first year. The average density reduction in the horizontal slices was between 50 and 150 Hounsfield units (HU) (approx. 10%; p<0.001) after 2 years. Loss of density is particularly strong distal of the minor trochanter and decreases from proximal to distal. For the 12 years retrospective study, the contralateral femur provided the control. Similar trends comparable to the prospective 2-year follow-up CT density values were seen in most cases with density reductions of up to 400 HU (30%). However, in one of these cases there was no difference between the operated and the control density. As far as we are aware, this is the first collection of fully prospective 3D validation data in vivo for periprosthetic adaptive bone remodelling theories. The data are also unique as they are suitable for direct patient-specific 3D finite element meshing and individual weight-related loading.

Absorptiometry, Photon↗

Exact focusing of extracorporeal shock wave therapy for calcifying tendinopathy.

A controlled prospective randomized study was designed to analyze the effect of extracorporeal shock wave therapy on calcifying tendinopathy of the shoulder focused on the calcified area or the origin of the supraspinatus tendon. Fifty patients were included in the study and were treated with a Storz Minilith Sl-1 shock wave generator. The first group of patients received 4000 impulses (positive energy flux density, 0.78 mJ/mm2) in two treatment sessions after receiving local anesthesia at the origin of the supraspinatus tendon. Patients in the second group received extracorporeal shock wave therapy at the calcified area. Follow-ups were done 12 weeks and 1 year after treatment by an independent observer. An increase of function and a reduction of pain occurred in both groups. Statistical analyses showed a significant superiority of extracorporeal shock wave application at the calcified area in the primary end point (Constant and Murley score). Therefore, exact fluoroscopic focusing of extracorporeal shock wave therapy at the calcific deposit for treatment of calcifying tendinopathy of the supraspinatus muscle is recommended. Based on these results, extracorporeal shock wave application should be focused fluoroscopically with appropriate shock wave generators.

Adult↗