PubMed Health⌕ Search

Biomedical subjects

Jane C Dale

Publications and source records attributed to Jane C Dale.

6 recordsLinked to original sources

Specimen collection volumes for laboratory tests.

CONTEXT: Unnecessary tests, inefficient ordering practices, and collection of more blood than is required for testing contribute to iatrogenic anemia in hospitalized patients. Laboratories accredited by the College of American Pathologists are expected to review phlebotomy practices for specimen collection volumes periodically. OBJECTIVE: To report specimen collection, analytic, and discard volumes for routine laboratory tests and to identify practice variables associated with overcollection and blood wastage. DESIGN: Clinical laboratories participating in the College of American Pathologists Q-Probes laboratory improvement program recorded collection container size, laboratory-defined requested volume, manufacturer-defined analytic volume, and average discard volume for routine complete blood cell counts and electrolyte panels ordered for patients in intensive care units. Participants provided information about their specimen collection, processing, and analytic practices in a questionnaire. SETTING AND PARTICIPANTS: A total of 140 public and private institutions. MAIN OUTCOME MEASURES: Overcollections for routine collections and for situations in which a reduced volume of specimen is collected, and average discard volume per tube. RESULTS: Laboratories collected a median of 2.76 mL (or 8.5 times) more than their instrument's analytic volume for routine complete blood cell counts and 1.75 mL (or 12 times) more than their instrument's analytic volume for routine electrolyte panels. For clinical situations in which reduced collection volumes were necessary, overcollection for the same analytes was 0.5 mL (3 times) and 0.44 mL (4.2 times), respectively. The median discard volume was 2.8 mL/tube for complete blood cell counts and 2.0 mL/tube for electrolyte panels. Specimen collection container size was directly associated with overcollections and discard volumes. Instrument analytic volume was not a determinant of blood wastage. CONCLUSIONS: Most laboratories can decrease collection volumes without compromising the ability of the laboratory to report a reliable and timely result. Use of smaller collection tubes can help reduce blood wastage.

Blood Specimen Collection↗

Diurnal variation of serum iron, iron-binding capacity, transferrin saturation, and ferritin levels.

Serum iron levels vary throughout the day. Morning levels are generally assumed to be higher than afternoon or evening levels. We studied whether our practice of restricting serum iron collections to the morning was necessary. Serum iron, iron-binding capacity, transferrin saturation, and ferritin levels were determined on blood specimens obtained from 20 healthy adult volunteers at 8 AM, noon, and 4 PM (day 1) and 8 AM (day 2). Although statistically significant differences among mean values for the collection times were observed for iron, iron-binding capacity, and (log) ferritin, no consistent diurnal variation was seen. Morning iron levels were higher than afternoon levels for only half of the subjects. Between-day variation for all 4 analytes was similar to within-day variation. We conclude that the practice of restricting iron specimen collections to a specific time of day does not improve the reliability of the test result.

Adult↗

Outpatient phlebotomy success and reasons for specimen rejection.

OBJECTIVES: To determine the rate with which blood collection is successful on the initial phlebotomy encounter, the rate with which laboratory personnel judge specimens unsuitable for analysis, and the practice characteristics associated with fewer unsuccessful collections and fewer rejected specimens. DESIGN: Clinical laboratories participating in the College of American Pathologists Q-Probes laboratory improvement program prospectively characterized the outcome of outpatient phlebotomies for 3 months or until 20 unsuccessful phlebotomy encounters occurred. By questionnaire, participants provided information about test ordering, patient preparation, and specimen collection. SETTING AND PARTICIPANTS: Institutions in the United States (n = 202), Canada (n = 4), Australia (n = 3), and South Korea (n = 1). MAIN OUTCOME MEASURES: Percentage of successful encounters and percentage of unsuitable specimens. RESULTS: Of 833289 encounters, 829723 were successful. Phlebotomies were unsuccessful because patients were not fasting as directed (32.2%), phlebotomy orders were missing information (22.5%), patients specimens were difficult to draw (13.0%), patients left the collection area before specimens were collected (11.8%), patients were improperly prepared for reasons other than fasting (6.3%), patients presented at the wrong time (3.1%), or for other reasons (11.8%). Only 2153 specimens (0.3%) were unsuitable; these samples were hemolyzed (18.1%), of insufficient quantity (16.0%), clotted (13.4%), lost or not received in the laboratory (11.5%), inadequately labeled (5.8%), at variance with previous or expected results (4.8%), or unacceptable for other reasons (31.1%). Facilities staffed by laboratory-administered phlebotomists reported higher success rates than facilities staffed by nonlaboratory-administered phlebotomists (P =.002). CONCLUSIONS: Most outpatient phlebotomy encounters are successful and result in specimens suitable for laboratory analysis.

Australia↗

Testing for group a streptococci.

CONTEXT: Laboratory diagnosis of group A streptococcal pharyngitis in physician office and small-hospital laboratories. OBJECTIVE: To characterize laboratory practices for the diagnosis of group A streptococcal pharyngitis and to identify opportunities for improvement. DESIGN: Voluntary self-assessment questionnaire, used to assess the laboratory practices of 790 laboratories subscribing to the College of American Pathologists Excel Microbiology Proficiency Testing Program. RESULTS: We observed discrepancies between self-reported and recommended specimen collection and laboratory testing practices for some laboratories. The most notable discrepancies were failing to provide a written specimen-collection procedure (17.8%), sampling the tongue and oral mucosa (2%), failing to always perform back-up cultures when rapid antigen test results were negative (57.5%), and finalizing culture reports within 24 hours or less (34.0%). Additionally, among those respondents who used the bacitracin disk, 57.9% (277 respondents) applied the disk directly onto a primary plate. CONCLUSIONS: Opportunities exist to improve testing practices for the diagnosis of group A streptococcal pharyngitis for some physician office and small-hospital laboratories.

Humans↗

Accuracy of rapid strep testing in patients who have had recent streptococcal pharyngitis.

BACKGROUND: Some clinicians have questioned the accuracy of rapid diagnosis of group A streptococcal pharyngitis by commercial immunochemical antigen test kits in the setting of recent streptococcal pharyngitis, believing that the false-positive rate was increased because of presumed antigen persistence. METHODS: We studied 443 patients--211 cases--who had clinical pharyngitis diagnosed as group A beta-hemolytic streptococcus infection in the past 28 days and compared them with 232 control patients who had symptoms of pharyngitis but no recent diagnosis of streptococcal pharyngitis. Our aim was narrowly focused to compare the rapid strep test with the culture method we used in our clinical practice. RESULTS: We found that the rapid strep test in this setting showed no difference in specificity (0.96 vs 0.98); hence, the assertion that rapid antigen testing had higher false-positive rates in those with recent infection was not confirmed. We also found that in patients who had recent streptococcal pharyngitis, the rapid strep test appears to be more reliable (0.91 vs 0.70, P < .001) than in those patients who had not had recent streptococcal pharyngitis. CONCLUSIONS: The findings of this study indicate that the rapid strep test is both sensitive and specific in the setting of recent group A beta-hemolytic streptococcal pharyngitis, and its use might allow earlier treatment in this subgroup of patients.

Antigens, Bacterial↗