PubMed Health⌕ Search

Biomedical subjects

Jane L P Roy

Publications and source records attributed to Jane L P Roy.

4 recordsLinked to original sources

Physiological responses of skilled players during a competitive wheelchair tennis match.

The purpose of this study was to determine heart rate (HR, b.min(-1)) response during competitive match play of 6 men who were skilled wheelchair (WC) tennis players. Each participant completed an arm crank ergometer test that measured HR via a telemetry device and O2 via open circuit spirometry from rest until fatigue (.V(O2)peak). Each athlete participated in 2 competitive singles matches during which HRs were recorded in 5-second intervals and O2 was estimated using the corresponding HR values recorded during the arm ergometer tests. Data analysis revealed an average playing intensity of 69.4 +/- 8.9% of HRpeak and 49.9 +/-14.5% of .V(O2)peak. In conclusion, it is recommended that skilled adult WC tennis players perform off-court aerobic conditioning as part of their training program, because the intensity of a competitive WC tennis match is sufficiently high enough to stress the cardiovascular system.

Adult↗

Preferred body type of fitness instructors among university students in exercise classes.

This study examined the relationship between participants' physique anxiety, eating behaviors, somatotype, and the preferred qualifications and body type of a fitness instructor. Subjects were 171 students attending fitness classes at a university. Analysis indicated that the women preferred a thinner fitness instructor than men and that enthusiasm, motivation, and being physically fit were considered the most important characteristics overall. No significant racial differences in key variables were found.

Adult↗

Prediction of maximal VO2 from a submaximal StairMaster test in young women.

The StairMaster 4000 PT is a popular step ergometer which provides a submaximal test protocol (SM Predicted VO(2)max) for the prediction of VO(2)max (ml.kg(-1).min(-1)). The purpose of this study was to evaluate the SM Predicted VO(2)max protocol by comparing it to results from a VO(2)max treadmill test in 20 young healthy women aged 20-25 years. Subjects were 10 step-trained (ST) women who had performed aerobic activities and exercised on a step ergometer for 20-30 minutes at least 3 times per week for the past 3 months, and 10 non-step-trained (NST) women who had performed aerobic activities no more than twice a week during the past 3 months and had no previous experience on a step ergometer. The SM Predicted VO(2)max protocol used 2 steady state heart rates between approximately 115-150 b.min(-1) to estimate VO(2)max. The Bruce maximal treadmill protocol (Actual VO(2)max) was used to measure VO(2)max by open circuit spirometry. Each subject performed both tests within a 7-day period. The means and standard deviations for the Actual VO(2)max tests were 39.8 +/- 6.1 ml.kg(-1).min(-1) for the ST group, 37.6 +/- 6.3 ml.kg(-1).min(-1) for the NST group, and 38.7 +/- 6.2 ml.kg(-1).min(-1) for the Total group (N = 20); and for the SM Predicted VO(2)max tests, means and standard deviations were 40.78 +/- 14.0 ml.kg(-1).min(-1), 30.9 +/- 4.8 ml.kg(-1).min(-1) and 35.9 +/- 11.4 ml.kg(-1).min(-1). There was no significant difference (p > 0.05) between the means of the Actual VO(2)max and SM Predicted VO(2)max test for the Total group (N = 20) or the ST group (n = 10), but a significant difference (p < 0.05) was shown for the NST group. The coefficient of determination (R(2)) and standard error of estimate (SEE) for the SM Predicted VO(2)max and Actual VO(2)max tests were R(2) = 0.18, SEE = 5.72 ml.kg(-1).min(-1) for the Total group; R(2) = 0.00, SEE = 6.68 ml.kg(-1).min(-1) for the NST group; and R(2) = 0.33, SEE = 5.32 ml.kg(-1).min(-1) for ST group. In conclusion, the SM Predicted VO(2)max test has acceptable accuracy for the ST group, but significantly underpredicted the NST group by almost 7 ml; and, as demonstrated by the high SEEs, it has a low level of precision for both ST and NST subjects.

Adult↗

Cardiovascular factors explain genetic background differences in VO2max.

The purpose of this study was to further explore factors that may be related to ethnic differences in the maximum rate at which an individual can consume oxygen (VO2max) between 20 African American (AA) and 30 European American (EA) sedentary women who were matched for body weight (kg) and fat-free mass (FFM). VO2max (l/min) was determined during a graded treadmill exercise test. Submaximal steady-state heart rate and submaximal VO2 were determined at a treadmill speed of 1.3 m/sec and a 2.5% grade. Hemoglobin (Hb) was determined by the cyanide method, muscle oxidative capacity by 31P magnetic resonance spectroscopy (ADP time constant), and FFM (kg) by dual-energy x-ray absorptiometry. Genetic classification was self-reported, and in a subset of the sample (N = 32), the determinants of ethnicity were measured by African genetic admixture. AA women had significantly reduced VO2max, Hb levels, and muscle oxidative capacity (longer ADP time constants, P < or = 0.05) than EA women. Submaximal oxygen pulse (O2Psubmax), ADP time constant, Hb, and ethnic background were all significantly related to VO2max (ml/kg/min and ml/kg FFM/min, all P < or = 0.01). By multiple regression modeling, Hb, O2Psubmax, muscle oxidative capacity, and ethnicity were found to explain 61% and 57% of the variance of VO2max in ml/kg/min and ml/kg FFM/min, respectively. Muscle oxidative capacity and O2Psubmax were both significantly and independently related to VO2max in all three models (P < or = 0.05), whereas Hb and ethnicity were not. These results suggest that mitochondrial muscle oxidative capacity and oxygen delivery capabilities, as determined by O2Psubmax, account for most if not all of the ethnic differences in VO2max.

Adenosine Diphosphate↗