PubMed Health⌕ Search

Biomedical subjects

Janiece L Hope

Publications and source records attributed to Janiece L Hope.

5 recordsLinked to original sources

Fisher ratio method applied to third-order separation data to identify significant chemical components of metabolite extracts.

This report is about applying a Fisher ratio method to entire four dimensional (4D) data sets from third-order instrumentation data. The Fisher ratio method uses a novel indexing scheme to discover the unknown chemical differences among known classes of complex samples. This is the first report of a Fisher ratio analysis procedure applied to entire 4D data sets of third-order separation data, which, in this case, is comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry analyses of metabolite extracts using all of the collected mass channels. Current analysis methods for third-order separation data use only user-defined subsets of the 4D data set. First, in a validation study, the Fisher ratio method was demonstrated to objectively evaluate and determine the chemical differences between three controlled urine samples that differed by known spiked chemical components. It was determined that, out of more than 600 recognizable chemical components in a single sample, the six spiked components, along with only two other matrix components, differed most significantly in concentration among the control samples. In a second study, the Fisher ratio method was used in a novel application to discover the unknown chemical differences between urine metabolite samples from pregnant women and nonpregnant women. A brief list of the top 11 components that were most significantly different in concentration between the pregnant and nonpregnant samples was generated. Because the Fisher ratio calculation statistically differentiates regions of the chromatogram with large class-to-class variations from regions containing large within-class variations, the Fisher ratio method should generally be robust against biological diversity in a sample population. Indeed, application of principal component analysis in this second study failed due to biological diversity of the samples.

Algorithms↗

Classification of gasoline data obtained by gas chromatography using a piecewise alignment algorithm combined with feature selection and principal component analysis.

A fast and objective chemometric classification method is developed and applied to the analysis of gas chromatography (GC) data from five commercial gasoline samples. The gasoline samples serve as model mixtures, whereas the focus is on the development and demonstration of the classification method. The method is based on objective retention time alignment (referred to as piecewise alignment) coupled with analysis of variance (ANOVA) feature selection prior to classification by principal component analysis (PCA) using optimal parameters. The degree-of-class-separation is used as a metric to objectively optimize the alignment and feature selection parameters using a suitable training set thereby reducing user subjectivity, as well as to indicate the success of the PCA clustering and classification. The degree-of-class-separation is calculated using Euclidean distances between the PCA scores of a subset of the replicate runs from two of the five fuel types, i.e., the training set. The unaligned training set that was directly submitted to PCA had a low degree-of-class-separation (0.4), and the PCA scores plot for the raw training set combined with the raw test set failed to correctly cluster the five sample types. After submitting the training set to piecewise alignment, the degree-of-class-separation increased (1.2), but when the same alignment parameters were applied to the training set combined with the test set, the scores plot clustering still did not yield five distinct groups. Applying feature selection to the unaligned training set increased the degree-of-class-separation (4.8), but chemical variations were still obscured by retention time variation and when the same feature selection conditions were used for the training set combined with the test set, only one of the five fuels was clustered correctly. However, piecewise alignment coupled with feature selection yielded a reasonably optimal degree-of-class-separation for the training set (9.2), and when the same alignment and ANOVA parameters were applied to the training set combined with the test set, the PCA scores plot correctly classified the gasoline fingerprints into five distinct clusters.

Algorithms↗

Evaluation of the DotMap algorithm for locating analytes of interest based on mass spectral similarity in data collected using comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry.

Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC x GC-TOF-MS) is a highly selective technique ideal for the analysis of complex mixtures. The instrument yields an abundance of data, with complete mass spectral scans at every time point in the GC x GC separation space. The development and application of appropriate tools for data mining is essential in making sense of the wealth of information available. An algorithm for locating analytes of interest based on mass spectral similarity in GC x GC-TOF-MS data, called DotMap, has been previously reported and is rigorously evaluated herein. A thorough investigation into the performance characteristics of DotMap, including the performance near the limit of detection and dynamic range of the algorithm as well as the capacity of the algorithm to deal with peak overlap, is investigated using jet fuel as a complex sample matrix. For instance, the algorithm can successfully identify a spiked compound at the single microg/ml level in a jet fuel sample with an overlapping interferent. The performance of the DotMap algorithm in situations with very limited mass spectral selectivity, specifically in the evaluation of spectra from isomer compounds, as well as the ability to tune DotMap results to provide the location of a specific analyte or of a class of compounds is demonstrated. The DotMap algorithm is demonstrated to be a sensitive tool that is useful in the analysis of complex mixtures and which possesses the capacity to be easily "tuned" to discern the location of analytes of interest.

Algorithms↗

Algorithm for locating analytes of interest based on mass spectral similarity in GC x GC-TOF-MS data: analysis of metabolites in human infant urine.

The developed algorithm reported herein, referred to as "DotMap," addresses the need to rapidly identify analyte peak locations in gas chromatography x gas chromatography-time of flight mass spectrometry (GC x GC-TOF-MS) data. The third-order structure of GC x GC-TOF-MS data is such that at each point in the GC x GC chromatogram, a complete mass spectrum is measured. DotMap utilizes this third-order structure to search for the location of a given spectrum of interest in a complete data set, or in a user selected portion of the complete data set. The algorithm returns a contour plot indicating the location of signal(s) with the most similar mass spectra to the analyte of interest. A spectrum from the region indicated is then subjected to an automated mass spectral search to give immediate feedback on the accuracy of the analysis. This algorithm was investigated with a trimethylsilyl (TMS) derivatized human infant urine sample that contained organic acid metabolites. One hundred percent of 12 selected TMS derivatized organic acid metabolites in human infant urine were located with the DotMap algorithm. A typical automated DotMap analysis takes 30 s on a 1.6 GHz PC with 1024 MB of RAM. Vanillic acid (TMS) was located by DotMap, but also exhibited overlap with other organic acids. The presence of vanillic acid (TMS) was confirmed by subjecting the appropriate GC x GC region to chemometric signal deconvolution by PARAFAC to yield pure component information suitable for subsequent quantification.

Algorithms↗

Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry subjected to chemometric peak deconvolution.

Two-dimensional gas chromatography (GC x GC) coupled to time-of-flight mass spectrometry (TOFMS) [GC x GC-TOFMS)] is a highly selective technique well suited to analyzing complex mixtures. The data generated is information-rich, making it applicable to multivariate quantitative analysis and pattern recognition. One separation on a GC x GC-TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this report, we demonstrate how GC x GC-TOFMS combined with trilinear chemometric techniques, specifically parallel factor analysis (PARAFAC) initiated by trilinear decomposition (TLD), results in a powerful analytical methodology for multivariate deconvolution. Using PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified without requiring a standard data set, signal shape assumptions or any fully selective mass signals. A set of four isomers (iso-butyl, sec-butyl, tert-butyl, and n-butyl benzenes) is used to investigate the practical limitations of PARAFAC for the deconvolution of isomers at varying degrees of chromatographic resolution and mass spectral selectivity. In this report, multivariate selectivity was tested as a metric for evaluating GC x GC-TOFMS data that is subjected to PARAFAC peak deconvolution. It was found that deconvolution results were best with multivariate selectivities over 0.18. Furthermore, the application of GC x GC-TOFMS followed by TLD/PARAFAC is demonstrated for a plant metabolite sample. A region of GC x GC-TOFMS data from a complex natural sample of a derivatized metabolic plant extract from Huilmo (Sisyrinchium striatum) was analyzed using TLD/PARAFAC, demonstrating the utility of this analytical technique on a natural sample containing overlapped analytes without selective ions or peak shape assumptions.

Evaluation Studies as Topic↗