PubMed Health⌕ Search

Biomedical subjects

Janusz Pawliszyn

Publications and source records attributed to Janusz Pawliszyn.

At least 19 recordsLinked to original sources

Characterization of plant growth-promoting rhizobacteria using capillary isoelectric focusing with whole column imaging detection.

Capillary isoelectric focusing (cIEF) can be a useful tool for the characterization and identification of microbes. Based on the whole column imaging detection (WCID) technique and using plant growth-promoting rhizobacteria (PGPR) as test microbes, we present a two-level cIEF characterization method for the characterization and identification of bacteria. Intact bacteria were first characterized according to their apparent isoelectric points measured by cIEF-WCID and then lysed bacteria were further characterized by cIEF profiling of the intracellular proteins. Cellular clustering was found to be the main experimental barrier for the characterization of intact bacteria. The addition of sodium chloride (100mM) to the sample mixture was found to be an effective way to reduce clustering. Due to the high efficiency and high resolution of cIEF-WCID, characterization of bacteria according to their intracellular proteins can be implemented simply and quickly without optimization of the experimental conditions. To improve the detection sensitivity with laser induced fluorescence (LIF)-WCID, the possibility to label bacteria with a non-covalent fluorescent dye, NanoOrange, was explored.

Bacterial Proteins↗

Fast and sensitive method to determine chloroanisoles in cork using an internally cooled solid-phase microextraction fiber.

A new generation of solid-phase microextraction (SPME) fiber, an internally cooled fiber (cold fiber with polydimethylsiloxane loading) that allows heating the sample matrix and simultaneously cooling the fiber coating, was used to determine 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole and pentachloroanisole in cork. A comparison between the cold fiber and regular SPME fiber was performed. An automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber (CF-HS-SPME) coupled to gas chromatography-time-of-flight mass spectrometry (GC-TOF-MS) was used. The extraction conditions for both CF-HS-SPME and HS-SPME were optimized using full factorial design and Doehlert matrix. The best extraction conditions for CF-HS-SPME were obtained using 10 min of incubation time, 10 min of extraction time, and sample and fiber temperature of 130 and 10 degrees C, respectively. For HS-SPME, polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used with 10 min of incubation time, 75 min of extraction time, 85 degrees C of sample temperature, 8 ml of water was added and agitated at 500 rpm. The quantification limits for the target compounds using CF-HS-SPME procedure were between 0.8 and 1.6 ng g(-1) of cork, while for HS-SPME were between 4 and 6 ng g(-1) of cork. Furthermore, the CF-HS-SPME procedure could be used as a non-destructive method after minor modification of the agitator for the autosampler.

Anisoles↗

Automation and optimization of liquid-phase microextraction by gas chromatography.

Several fully automated liquid-phase microextraction (LPME) techniques, including static headspace LPME (HS-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and exposed to the headspace of the sample solution), exposed dynamic HS-LPME (the solvent is exposed in the headspace of sample vial for different time, and then withdrawn into the barrel of the syringe. This procedure is repeated a number of times), unexposed dynamic HS-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the gaseous sample is withdrawn into the barrel and then ejected), static direct-immersed LPME (DI-LPME) (a drop of solvent is suspended at the tip of a microsyringe needle and directly immersed into the sample solution), dynamic DI-LPME (the solvent is moved inside the needle and the barrel of a syringe, and the sample solution is withdrawn and ejected), and two phase hollow fiber-protected LPME (HF-LPME) (a hollow fiber is used to stabilize and protect the solvent), auto-performed with a commercial CTC CombiPal autosampler, are described in this paper. Critical experimental factors, including temperature, choice of extraction solvent, solvent volume, plunger movement rate, and extraction time were investigated. Among the three HS-LPME techniques that were evaluated, the exposed dynamic HS-LPME technique provided the best performance, compared to the unexposed dynamic HS-LPME and static HS-LPME approaches. For DI-LPME, the dynamic process can enhance the extraction efficiency and the achieved method precision is comparable with the static DI-LPME technique. The precision of the fully automated HF-LPME is quite acceptable (RSD values below 6.8%), and the concentration enrichment factors are better than the DI-LPME approaches. The fully automated LPME techniques are more accurate and more convenient, and the reproducibility achieved eliminates the need for an internal standard to improve the method precision.

Chemistry Techniques, Analytical↗

Time-weighted average water sampling with a diffusion-based solid-phase microextraction device.

A new diffusion-based solid-phase microextraction (SPME) time-weighted average (TWA) field water sampling device was developed and investigated by field trial. The sampler is constructed with copper tube and caps and a commercial SPME fiber assembly. The device possesses all advantages of SPME; it is solvent-free, reusable, combines sampling, isolation and enrichment into one step, and the fiber can be directly injected into a gas chromatograph for analysis with a commercial SPME fiber holder, without further treatment. Field trials in Laurel Creek (Waterloo, Ont., Canada) and Hamilton Harbour (Hamilton, Ont., Canada) illustrated that the device is durable, easy to deploy, and the mass uptake of the device is independent of the face velocity. The device provides good precision [relative standard deviations (RSDs) are less than 20%] and the data obtained with this device are quite comparable to those obtained with the spot sampling method, which demonstrates that the newly developed SPME water sampling device is suitable for long-term monitoring of organic pollutants in water.

Diffusion↗

Screening of tropical fruit volatile compounds using solid-phase microextraction (SPME) fibers and internally cooled SPME fiber.

In this study, the optimization and comparison of an internally cooled fiber [cold fiber with polydimethylsiloxane (PDMS) loading] and several commercial solid-phase microextraction (SPME) fibers for the extraction of volatile compounds from tropical fruits were performed. Automated headspace solid-phase microextraction (HS-SPME) using commercial fibers and an internally cooled SPME fiber device coupled to gas chromatography-mass spectrometry (GC-MS) was used to identify the volatile compounds of five tropical fruits. Pulps of yellow passion fruit (Passiflora edulis), cashew (Anacardium occidentale), tamarind (Tamarindus indica L.), acerola (Malphigia glabra L.), and guava (Psidium guajava L.) were sampled. The extraction conditions were optimized using two experimental designs (full factorial design and Doehlert matrix) to analyze the main and secondary effects. The volatile compounds tentatively identified included alcohols, esters, carbonyl compounds, and terpernes. It was found that the cold fiber was the most appropriate fiber for the purpose of extracting volatile compounds from the five fruit pulps studied.

Alcohols↗

In vivo sampling with solid phase microextraction.

This review discusses the most recent developments and future challenges in the application of solid phase microextraction (SPME) for sampling of live biological samples. The emphasis is placed on applications of fiber SPME for analysis of volatile emissions and drugs in biological fluids. The method development section highlights the main parameters that need to be considered in the case of in vivo experiments: extraction techniques, selection of extraction phases, calibration procedures, determination of free concentrations, and automation.

Drug Evaluation, Preclinical↗

Kinetic calibration for automated hollow fiber-protected liquid-phase microextraction.

Recently, a kinetic calibration method was developed for the quantification of microextraction. In this study, we proved that the sample volume and sampling time do not affect the feasibility of the calibration method, theoretically. The new theoretical considerations of the kinetic calibration method were validated through the investigation of the kinetics of the absorption and desorption processes of hollow fiber-protected liquid-phase microextractrion (HF-LPME). The kinetic calibration method for HF-LPME was successfully used to correct the matrix effects in the carbaryl analysis of a red wine sample. This research extends the kinetic calibration approach to fast sampling and some in-vial analyses, whereby the sample volume is not much larger than the product of the distribution coefficient and the volume of the extraction phase. HF-LPME technique was successfully automated with a CTC CombiPal autosampler, and a new device was designed for the automation of HF-LPME in this study. All steps of the HF-LPME technique, including the filling of the extraction solvent, sample transfer and agitation, withdrawing the solvent to a syringe, and introducing the extraction phase into the injector, were automated by a CTC autosampler. The fully automated HF-LPME technique is more convenient and more accurate. The good reproducibility of the fully automated HF-LPME technique eliminates the need for an internal standard to improve the analytical precision. The automated HF-LPME technique can be also used to obtain the distribution coefficient between the sample matrix and the extraction phase. The distribution coefficients of carbaryl and (13)C-carbaryl between 1-octanol and red wine, at 25 degrees C, were obtained with this technique.

Journal Article↗

Analysis of human breath with micro extraction techniques and continuous monitoring of carbon dioxide concentration.

The detection of volatile organic compounds (VOCs) in human breath can be useful for the clinical routine diagnosis of several diseases in a non-invasive manner. Traditional methods of breath analysis have some major technical problems and limitations. Membrane extraction with a sorbent interface (MESI), however, has many advantages over current methods, including good selectivity and sensitivity, and is well suited for breath analysis. The aim of this project was to develop a simple and reproducible sampling device and method based on the MESI system for breath analysis. The feasibility and validity of the MESI system was tested with real human breath samples. Internal standard calibration methods were used for the quantitative analysis of various breath samples. Calibration curves for some main components (target analytes such as acetone and pentane) were determined in the research. The optimized stripping-side and feeding-side gas velocities were determined. The use of breath CO2 as an internal standard for the analysis of breath VOCs is an effective method to solve the difficulties associated with variations in the target analyte concentrations in a sample, which are attributed to mass losses and different breathing patterns of different subjects. In this study, the concentration of breath acetone was successfully expressed normalized to CO2 as in the alveolar air. Breath acetone of healthy males and females profiled at different times of the day was plotted using the MESI system, and results were consistent with the literature. This technique can be used for monitoring breath acetone concentrations of diabetic patients and for applications with other biomarker monitoring.

Acetone↗

Miniaturization and automation of an internally cooled coated fiber device.

The internally cooled coated fiber device was miniaturized to allow its direct introduction into a gas chromatography injector, while maintaining a reasonable lifetime of the septum. The device was robust, and its fiber, which was accommodated in an 18-gauge needle, was reproducibly used for more than 100 injections without any coating failure. The fiber temperature was controlled within 5 degrees C of the preset value by use of a temperature controller, a solenoid valve, and stainless steel tubings with different inner diameter. The device was mounted and used on the CTC CombiPAL autosampler with minor modifications, such as enlarging the hole of the needle guide of the autosampler and coupling the temperature control system of the device to the autosampler through a logic circuit. The device was validated with the back equilibration of hydrocarbons preloaded in the fiber in air. The automation of the internally cooled coated fiber device provided the feasibility of high throughput for the analysis of analytes in complex matrixes that required simultaneous heating of the sample matrixes and cooling of the fiber coating.

Journal Article↗

On-rod standardization technique for time-weighted average water sampling with a polydimethylsiloxane rod.

In this study, a polydimethylsiloxane (PDMS) rod was developed as a passive sampler, based on the solid-phase microextraction (SPME) technique. The on-rod standardization technique was applied to the PDMS rod passive sampler. Using the desorption of the pre-loaded standard on the PDMS rod to calibrate the absorption of the target analytes allows for the determination of the time-weighted average (TWA) concentrations of pollutants in the aqueous media. The PDMS rod passive sampler with the on-rod standardization technique was tested in the laboratory with a flow-through system and was subsequently applied to measure TWA concentrations of polycyclic aromatic hydrocarbons (PAHs) in the field (Hamilton Harbour, Hamilton, Ont., Canada). Both the laboratory and field experiments demonstrated that, with the on-rod standardization technique, the PDMS rod can be successfully used as a passive sampler for TWA water sampling in the field. The PDMS rod passive sampler benefits from the inherent advantages of the SPME approach: it incorporates sampling, isolation and enrichment into one step. The design of this system also addressed the additional needs for passive sampling techniques, providing an economical approach to field sampling that is also easy to deploy. Rather, with this approach, TWA concentrations of target analytes can be obtained by one sampler, and can be analyzed directly, with no further sample preparation treatment required.

Chromatography, Liquid↗

New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment.

A new automated headspace solid-phase microextraction (HS-SPME) sampling device was developed, with the capability of heating the sample matrix and simultaneously cooling the fiber coating. The device was evaluated for the quantitative extraction of polycyclic aromatic hydrocarbons (PAHs) from solid matrices. The proposed device improves the efficiency of the release of analytes from the matrix, facilitates the mass transfer into the headspace and significantly increases the partition coefficients of the analytes, by creating a temperature gap between the cold-fiber (CF) coating and the hot headspace. The reliability and applicability of previously reported cold-fiber devices are significantly enhanced by this improvement. In addition, it can be easily adopted for full automation of extraction, enrichment and introduction of different samples using commercially available autosampling devices. Sand samples spiked with PAHs were used as solid matrices and the effect of different experimental parameters were studied, including the extraction temperature, extraction time, moisture content, and the effect of sonication and modifier under optimal experimental conditions, linear calibration curves were obtained in the range of 0.0009-1000 ng/g, with regression coefficients higher than 0.99 and detection limits that ranged from 0.3 to 3 pg/g. Reproducible, precise and high throughput extraction, monitoring and quantification of PAHs were achieved with the automated cold-fiber headspace solid-phase microextraction (CF-HS-SPME) device coupled to GC-flame ionization detection. Determination of PAHs in certified reference sediments using the proposed approach exhibited acceptable agreement with the standard values.

Calibration↗

SPME in environmental analysis.

Recent advances in the use of solid-phase microextraction (SPME) in environmental analysis, including fiber coatings, derivatization techniques, and in-tube SPME, are reviewed in this article. Several calibration methods for SPME, including traditional calibration methods, the equilibrium extraction method, the exhaustive extraction method, and several diffusion-based calibration methods, are presented. Recent developed SPME devices for on-site sampling and several applications of SPME in environmental analysis are also introduced.

Journal Article↗

Internal calibrant in the stripping gas. An approach to calibration of membrane extraction with a sorbent interface.

A new technique for calibration in membrane extraction processes by adding an analytically noninterfering internal calibrant in the stripping gas is described. Membrane extraction with a sorbent interface (MESI) system was used to evaluate this method. During the membrane extraction process, the internal calibrant present in the carrier (stripping) gas and the target analyte present in the sample matrix will permeate simultaneously through the membrane in opposite directions. The changes of accumulation amounts of internal calibrant in the microtrap can be used as a means of calibration to correct the variations of extraction rate due to the variation in environmental factors, such as the sample velocity and the membrane temperature. Thus, this approach should allow for more accurate estimates of the concentrations of target analytes at various sampling or monitoring conditions during field analysis. Finally, a group of selected compounds was employed to test this calibration strategy, and the results indicated the advantages of the proposed approach for on-site analysis.

Journal Article↗

Fast in vivo microextraction: a new tool for clinical analysis.

BACKGROUND: We sought to develop a technique with the potential to partly replace current methods of analysis based on blood draws. To achieve this goal, we developed an in vivo microextraction technique that is faster than conventional methods, interferes minimally with the investigated system, minimizes errors associated with sample preparation, and limits exposure to hazardous biological samples. METHODS: Solid-phase microextraction devices based on hydrophilic polypyrrole and polyethylene glycol coatings were used for direct extraction of drugs from the flowing blood of beagle dogs, over a period of 8 h. The drugs extracted on the probes were subsequently quantified by liquid chromatography coupled to tandem mass spectrometry. Two calibration strategies--external and standard on the fiber--were used to correlate the amount extracted with the in vivo concentration. RESULTS: Diazepam and its metabolites were successfully monitored over the course of a pharmacokinetic study, repeated 3 times on 3 beagles. The fast microextraction technique was validated by comparison with conventional plasma analysis, and a correlation factor of 0.99 was obtained. In addition to total concentrations, the method was useful for determining free drug concentrations. CONCLUSIONS: The proposed technique has several advantages and is suitable for fast clinical analyses. This approach could be used not only for drugs, but for any other endogenous or exogenous compounds.

Animals↗

Microdialysis hollow fiber as a macromolecule trap for on-line coupling of solid phase microextraction and capillary electrophoresis.

On-line coupling of solid phase microextraction (SPME) and capillary electrophoresis (CE) is highly desirable due to the apparent advantages of the two techniques particularly in the context of microanalysis. However, the hyphenation is a significant challenge, because of band broadening and analyte carryover caused by the slow kinetics of analyte desorption in liquid phase. A novel strategy was presented in this study to overcome these problems. Analytes desorbed from an SPME fiber, which was held by an adapter, were first transferred by electrophoretic migration into a short piece of microdialysis hollow fiber, which was located at the inlet of a CE system. Analytes with molecular weights greater than the molecular weight cut-off of the microdialysis material were trapped in the microdialysis hollow fiber due to the dialysis effect. Then, under another electric field with different electrode polarity, the analytes trapped in the microdialysis hollow fiber migrated into the separation capillary and were separated. In the coupling approach, the microdialysis hollow fiber functioned as a macromolecule trap and a sample pre-concentrator as well. Band broadening was eliminated because the initial sample volume was very small (at nL level). Meanwhile, analyte carryover was eliminated because the desorption time could be as long as needed. Coupling of SPME with CE including two modes, capillary zone electrophoresis (CZE) and capillary isoelectric focusing (CIEF), was successfully demonstrated with proteins as test analytes. High efficiency and high resolution were obtained. The detection limits with UV absorbance whole-column imaging detection were 3.0 x 10(-7) and 3.0 x 10(-8) M (S/N = 3) for beta-lactoglobulin A and ovalbumin, respectively.

Journal Article↗

Dynamic process of phospholipid-protein interaction studied by capillary isoelectric focusing with whole-column imaging detection.

Liposomes are vesicles formed by the aggregation of amphiphilic phospholipid molecules, which can mimic natural cell membranes. Interaction between liposome and protein is important for the structure and function of natural cell membranes. In this study, a CIEF method with whole-column imaging detection was developed for monitoring the dynamic process of phospholipid-protein interactions. The CIEF profiles at successive interaction times clearly displayed the formation of the different conjugates between phospholipid and protein at different stages. Due to the diversity of the chemical and physical properties of targeted proteins in this study (trypsin inhibitor, beta-lactoglobulin B, phosphorylase b, and trypsinogen), different dynamic processes of phospholipid-protein interactions were exhibited. The type of phospholipids played an important role in the dynamic process of phospholipid-protein interaction, as noted by the use of zwitterionic phospholipid (phosphatidylcholine) and acidic phospholipid (phosphatidylserine). Mechanisms involved in these interactions were discussed by monitoring the dynamic processes in this study.

Electrophoresis, Capillary↗

Determination of drug plasma protein binding by solid phase microextraction.

The plasma protein binding of drugs has been shown to have significant effects on the quantitative relationship between clinical pharmacokinetics and pharmacodynamics. In many clinical situations, measurement of the total drug concentration does not provide the needed information concerning the unbound fraction of drug in plasma, which is available for pharmacodynamic action. Therefore, the accurate determination of unbound plasma drug concentrations is important in understanding drug action. Many methodologies exist for determining the extent of plasma protein binding, but different methods produce a rather wide range of results for the same compound at the same concentration level. The solid phase microextraction (SPME) method reported in the present study attempts to eliminate many experimental variables that could lead to the lack of reproducibility, such as the variable content of organic solvent or ionic strength in plasma, pH shifts, and volume shifts. Five well-known drugs were chosen to study plasma protein binding: ibuprofen, warfarin, verapamil, propranolol, and caffeine, with high, intermediate and low binding properties. Dilution of plasma with isotonic PBS or incubation with 10% CO(2) in the atmosphere was found to compensate for changes in pH during incubation. The data obtained using these pH-controlled methods correlate well with the average values of plasma protein binding found in the literature. SPME, which uses an extraction phase that dissolves or adsorbs the drug of interest and rejects proteins, overcomes several limitations of currently available techniques and is a thermodynamically sound method, since the measurements are always performed at equilibrium. Compared to other methods, SPME offers several advantages: small sample size, short analysis time, possibility to automate, and ability to directly study complex samples.

Blood Proteins↗

Protein thermal stability and phospholipid-protein interaction investigated by capillary isoelectric focusing with whole column imaging detection.

CIEF with whole column imaging detection (WCID) is an attractive technique for studying protein reaction and protein-ligand interaction due to its fast separation, simple operation, and high efficiency. In this study, two interesting applications by the CIEF-WCID were developed, involving the study of protein thermal stability and phospholipid-protein interaction. Four proteins (beta-lactoglobulin B, trypsin inhibitor, phosphorylase b, and trypsinogen) with different pI, and two types of phospholipids, including phosphatidylcholine (PC) and phosphatidylserine (PS), were used for this purpose. First, the altered CIEF profiles of four proteins were exhibited due to conformational changes resulting from protein denaturation induced by a high incubation temperature at 60 degrees C. It was demonstrated that the addition of a zwitterionic phospholipid (PC) played a crucial role in the thermal stability of targeted proteins, especially for trypsin inhibitor whose thermal stability was promoted with the addition of the PC vesicles at 60 degrees C. Second, the zwitterionic (PC) and acidic (PS) phospholipids displayed completely different interactions with the proteins. The addition of PS vesicles modified the zwitterionic phospholipids to carry negative charges, which correspondingly changed the interaction between the phospholipid and the protein. Our study demonstrates that the CIEF-WCID is a powerful approach to study protein reaction and protein-ligand interaction with high efficiency, high selectivity, and fast separation.

Chromatography↗