Analysis of anatoxin-a in aqueous samples by solid-phase microextraction coupled to high-performance liquid chromatography with fluorescence detection and on-fiber derivatization.

A simple method for analysis of anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and high-performance liquid chromatography (HPLC) with fluorescence detection. Anatoxin-a was derivatized to a fluorogenic agent on the surface of the SPME fiber. In the method an SPME fiber was immersed for 30 min in the aqueous sample. The fluorogenic derivatizing reagent (4-fluoro-7-nitro-2,1,3-benzoxadiazole, 1.0 mg/ml in methanol) was dropped or sprayed onto the fiber containing extracted analytes. The fiber was then heated for 10 min in an empty vial at 70 degrees C in a waterbath to promote derivatization. The derivatives formed on the fiber were desorbed in a SPME-HPLC interface. The interface was filled with methanol-1 mM hydrochloric acid (7:3, v/v) before inserting of the fiber into the interface. For desorption, the fiber was inserted in the interface for 5 min. For anatoxin-a in an aqueous sample, the calibration curve showed linearity in the range of 50-1500 ng/ml and the limit of detection of anatoxin-a was 20 ng/ml. No interferences were found, and the time for analysis was 55 min for one sample.

Bacterial Toxins↗

Microwave-assisted generation of standard gas mixtures.

Microwave heating was employed for preparation of the standard gas of volatile organic compounds (VOCs) and semivolatile organic compounds (semi-VOCs) by using a 1000 W commercial domestic microwave oven and 1 L gas-sampling bulbs. The VOCs investigated were benzene, chloroform, 1,3-dichlorobenzene, tetrachloroethylene, toluene, and 1,1,2-trichloroethane, and the semi-VOCs used were the polychlorinated biphenyls (PCBs) PCB 1016 and PCB 1248. Since these weakly or nonpolar molecules are very poor absorbers of microwave energy, an appropriate amount of water was introduced to accept microwave radiation and act as the thermal source to accelerate their evaporation. The glass bulb may also contribute thermal energy to the VOCs/semi-VOCs by accepting microwave energy to a small degree. For 0.5 microL of liquid VOCs on 10 mg of glass wool, it was shown that 15 microL of H2O and 60 s of microwave heating yielded a very efficient evaporation [97.2-106.4%, compared with a classic method (Muller, L; Gorecki, T.; Pawliszyn, J. Fresenius' J. Anal. Chem. 1999, 364, 610-616)]. For 1 microL of PCB solution (1000 microg/mL in hexane), 15 microL of H2O and 90 s of microwave heating also provided a complete evaporation. The addition of water was particularly significant for microwave-assisted evaporation of PCBs because semi-VOCs are much more difficult to evaporate than VOCs. This developed microwave technique proved to be quite simple, powerful, rapid, accurate, and safe for the preparation of VOC/semi-VOC standard gas. Solid- phase microextraction combined with gas chromatography was used for the gas analysis.

Air Pollution↗

Automated in-tube solid-phase microextraction coupled with HPLC for the determination of N-nitrosamines in cell cultures.

An automated in-tube solid-phase microextraction (SPME) HPLC analysis method for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and several metabolites has been developed. NNK is one of the tobacco-specific N-nitrosamines (TSNA), which has been linked to cancers associated with the use of or exposure to tobacco products. In-tube SPME is an on-line extraction technique in which analytes are extracted and concentrated from the sample directly into a coated capillary by repeated draw/eject steps. In this study, a tailor-made polypyrrole (PPY)-coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for NNK and several metabolites in cell cultures. Compared with commercial capillaries that were currently used for in-tube SPME, the PPY-coated capillary showed better extraction efficiency for all of the compounds studied. After optimization of the extraction conditions, NNK and five metabolite compounds were analyzed in spiked cell cultures, confirming the applicability of the developed method. Excellent linearity was observed for all compounds (av R2 = 0.9942) and detection limits that ranged from 20 to 250 ng/mL. The average within-day and between day variations (% RSD) were 2.9 and 3.6%, respectively. This automated extraction and analysis method simplified the determination of the TSNA, requiring a total sample analysis time of only approximately 30 min.

Animals↗

Direct determination of benzodiazepines in biological fluids by restricted-access solid-phase microextraction.

A biocompatible solid-phase microextraction (SPME) fiber was prepared using an alkyl-diol-silica (ADS) restricted-access material as the SPME coating. The ADS-SPME fiber was able to simultaneously fractionate the protein component from a biological sample, while directly extracting several benzodiazepines, overcoming the present disadvantages of direct sampling in biological matrixes by SPME. The fiber was interfaced with an HPLC-UV system, and an isocratic mobile phase was used to desorb, separate, and quantify the extracted compounds. The calculated clonazepam, oxazepam, temazepam, nordazepam, and diazepam detection limits were 600, 750, 333, 100, and 46 ng/mL in urine, respectively. The method was confirmed to be linear over the range of 500-50000 ng/mL with an average linear coefficient (R2) value of 0.9918. The injection repeatability and intraassay precision of the method were evaluated over 10 injections, resulting in a RSD of approximately 6%. The ADS-SPME fiber was robust and simple to use, providing many direct extractions and subsequent determination of benzodiazepines in biological fluids.

Anti-Anxiety Agents↗

Whole-column imaging capillary electrophoresis of proteins with a short capillary.

Whole-column imaging capillary electrophoresis with a short capillary is discussed. A short capillary (3-6 cm) coated with either fluorocarbon or polyacrylamide was used as a separation capillary. The whole capillary was illuminated with 280 nm light, and the transmitted light was monitored by a linear charge-coupled device (CCD). For the short capillary, hydrodynamic flow caused by a subtle height difference between the anodic and cathodic reservoirs affected the sample migration in the capillary greatly. Several sample injection methods, including use of a cross connection, sealing of the capillary ends with a gel, and use of a gel-filled capillary, have been discussed. The experimental results showed that the peak height decreased and peak width increased with the electromigration distance. Therefore, higher sensitivity was obtained in a short capillary rather than a long capillary. The whole-column imaging CE with the short capillary has been applied for the study of conjugation reactions of protein cytochrome c with sodium dodecyl sulfate (SDS) and the dye Congo Red. The method has also been used for in situ monitoring of the electrophoretic protein desorption process. Our technique is a unique tool for the study of protein binding reactions and the interaction between analyte and inner wall of the capillary.

Adsorption↗

Microfabrication of a tapered channel for isoelectric focusing with thermally generated pH gradient.

A simple microfabrication technique for the preparation of a tapered microchannel for thermally generated pH gradient isoelectric focusing (IEF) has been demonstrated. The tapered channel was cut into a plastic sheet (thickness was 120 microm), and the channel was closed by sandwiching the plastic sheet between two glass microscope slides. The length of the microchannel was 5 cm. The width of the separation channel was 0.4 mm at the narrow end and 4 mm at the wide end. The channel was coated with polyacrylamide to prevent electroosmotic flow (EOF) during focusing. Two electrolyte vials were mounted on top of each end of the channel with the wide end of the channel connected to the cathodic vial and the narrow to the anodic vial. The feasibility of the thermally generated pH gradient in a tapered channel was demonstrated. Important parameters that determined the feasibility of using a thermally generated pH gradient in a tapered channel were analyzed. Parameters to be optimized were control of EOF and hydrodynamic flow, selection of power supply mode and prevention of local overheating and air bubble formation. Tris-HCl buffer, which has a high pK(a) dependence with temperature, was used both to dissolve proteins and as the electrolyte. The thermally generated pH gradient separation of proteins was tested by focusing dog, cat and human hemoglobins with a whole column detection capillary IEF (CIEF) system.

Hemoglobin A↗

A laboratory technique for investigation of diffusion and transformation of volatile organic compounds in low permeability media.

A laboratory diffusion cell technique that permits spatial and temporal estimates of porewater concentrations over short intervals suitable for estimation of effective diffusion coefficients (De) and degradation rate constants (k) of volatile organic compounds (VOCs) in saturated low permeability media is presented. The diffusion cell is a sealed cylinder containing vapour reservoirs for sampling, including a vapour reservoir source and an array of vapour-filled "mini-boreholes", which are maintained water- and sediment-free by slightly negative porewater pressures. The vapour reservoirs were sampled by Solid Phase Micro-Extraction (SPME), resulting in minimal disturbance to the experimental system. Porewater concentrations are estimated from the measured vapour concentrations. Experiments were conducted using a non-reactive medium and five VOCs with a range in partitioning properties. Calibration experiments showed that equilibrium partition coefficients could be used for calculating concentrations in the vapour reservoir source from concentrations in the SPME coating after a 1-min microextraction and that the reservoir concentration was insignificantly affected by sampling. However, equilibrium was not reached during the one-min extraction of the boreholes; the microextraction reduced the borehole vapour concentrations, leading to diffusion of VOCs from porewater into the vapour-filled borehole. Thus, empirical partitioning coefficients were required for the determination of porewater VOC concentrations. The experimental data and numerical modelling indicate masses extracted by SPME extraction are relatively small, with minimal perturbation on processes studied in diffusion experiments. This technique shows promise for laboratory investigation of diffusion and transformation processes in low permeability media.

Carbon Disulfide↗

Membrane extraction with sorbent interface-gas chromatography as an effective and fast means for continuous monitoring of thermal degradation products of polyacrylonitrile.

A novel sample preparation technique, membrane extraction with a sorbent interface (MESI) has been optimized and used for continuous monitoring thermal degradation products in polyacrylonitrile (PAN) polymer headspace at different temperatures, followed by gas chromatography-mass spectrometry (GC-MS). MESI with a flat sheet poly(dimethyl siloxane)-polycarbonate (PDMS-PC) membrane and Tenax trap was used. The system is very simple, fast and reliable and allowed us to extract, enrich and continuously monitor major volatile compounds released from the polymer at different temperatures. The volatile and semi-volatile gaseous degradation products were identified. Sensitivity of the method depends on the length of time for trapping.

Journal Article↗

Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry.

Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.

Enkephalins↗

Comprehensive two dimensional separation based on coupling micellar electrokinetic chromatography with capillary isoelectric focusing.

Concentrating properties of the Capillary Isoelectric Focusing (CIEF) system with continuous whole-column-imaging detection were investigated for application as a second dimension in a comprehensive two-dimensional (2D) separation process. The concentration/separation/detection was completed within 4 min in a 300 microm inner diameter capillary. As the key to the successful coupling of CIEF to a first dimension separation, a novel interface was developed. A 10-port valve with two conditioning loops was used to perform both comprehensive collection and dialysis desalting of the first dimensional effluent, and as an interface coupling Micellar Electrokinetic Chromatography (MEKC) to CIEF. In the loop, salt and other unwanted first dimension effluent components were eliminated by dialysis and carrier ampholytes (CAs) were added. Peak broadening during the dialysis did not have significant impact on the CIEF separation because of its concentrating effect. Protein digests were first separated by MEKC followed by isoelectric point (pI) using whole-column-imaged CIEF. The dialysis interface allows general coupling of the whole-column-imaged CIEF to microscale separations.

Animals↗

Automation of solid-phase microextraction-gas chromatography-mass spectrometry extraction of eucalyptus volatiles.

Solid-phase microextraction (SPME) coupled with gas chromatography (GC)-ion-trap mass spectrometry (ITMS) is employed to analyze fragrance compounds from different species of eucalyptus trees: Eucalyptus dunnii, Eucalyptus saligna, Eucalyptus grandis, and hybrids of other species. The analyses are performed using an automated system for preincubation, extraction, injection, and analysis of samples. The autosampler used is a CombiPAL and has much flexibility for the development of SPME methods and accommodates a variety of vial sizes. For automated fragrance analysis the 10- and 20-mL vials are the most appropriate. The chromatographic separation and identification of the analytes are performed with a Varian Saturn 4D GC-ITMS using an HP-5MS capillary column. Several compounds of eucalyptus volatiles are identified, with good reproducibility for both the peak areas and retention times. Equilibrium extraction provides maximal sensitivity but requires additional consideration for the effect of carryover. Preequilibrium extraction allows good sensitivity with minimal carryover.

Eucalyptus↗

Continuous monitoring of thermooxidative degradation products of polystyrene by membrane extraction with sorbent interface and gas chromatography.

A novel method for the continuous monitoring of thermooxidative degradation products of polystyrene by membrane extraction with sorbent interface (MESI) and gas chromatography (GC) is developed. The results are compared with solid-phase microextraction-GC, which can extract gases, vapors, and aerosols. The volatile and semivolatile degradation products are identified by mass spectrometry. The membrane used in the MESI-GC analysis shows a high permeation for volatile aromatic hydrocarbons; a low permeation for corresponding volatile aldehydes; and no permeation for less volatile alcohols, acids, and degradation products with a high molecular weight, thus reducing significantly the number of compounds detected from MESI-GC. Sensitivity of the method depends on the time of trapping, which is limited by the breakthrough of the trap. By heating the trap at fixed intervals of time, consecutive gas chromatograms are obtained.

Journal Article↗

Capillary isoelectric focusing with laser-induced fluorescence whole column imaging detection as a tool to monitor reactions of proteins.

Capillary isoelectric focusing (CIEF) with laser-induced fluorescence (LIF) whole column imaging detection (WCID) has the characteristics of high resolution, high speed and high sensitivity for separation of amphoteric biomolecules. These features enable a CIEF-LIF-WCID system to monitor the dynamic process of a protein reaction. The reaction can be a physical change or a chemical reaction, provided that the kinetics of the reaction is slower than the focusing speed or that the intermediates involved have long enough life-span compared to the analysis time. The processes of denaturation (a physical reaction), reduction and carbamylation (both chemical reactions) were dynamically monitored. The CIEF profiles at successive reaction times clearly displayed the formation of different products at different stages. At incomplete denaturation, intermediates with higher apparent pI values relative to the products at complete denaturation were detected. Carbamylation products of a protein were detected when the protein reacted with a urea solution that had prepared three months earlier, exhibiting gradually decreased pI values. Mechanisms involved in these reactions were rationalized. A combined mechanism of denaturation and reduction was suggested to explain the denaturing process under high concentrations of urea. Potential applications and critical factors to manipulate these reactions were also discussed.

Animals↗

Study of ligand-receptor binding using SPME: investigation of receptor, free, and total ligand concentrations.

The theoretical background and practical approaches for studying ligand-receptor (protein) binding by solid phase microextraction (SPME) are investigated, along with methods for simultaneous calculation of receptor, free, and total ligand concentrations. With the introduction of new extraction phases (restricted access materials, molecularly imprinted polymers, and immobilized antibodies), SPME allows better separation of small molecules of ligand from larger molecules of receptor, and improved accuracy. This sample preparation method based on nonexhaustive extraction is well suited as a general method to study and quantify systems involving multiple equilibriums, with significant advantages over currently used methods. SPME was used previously for the determination of protein binding constants, but only with conventional extraction phases and in simple cases, with a 1:1 combination ratio between the ligand and the receptor or when negligible depletion conditions were met. The new theoretical approach presented in this study allows the quantification of any binding equilibrium, regardless of the extent of depletion. Restricted-access particles are used as extraction phase, and if the amount of receptor is limited, selected regions of the binding curve may be obtained using a single sample, with a volume as low as 10 muL. The equations developed here are simple and independent of the analytical method used for the quantification of the amount of ligand. Three different practical approaches are presented: the method of multiple standard solutions, the method of successive extractions from the same sample and the method of successive additions to the same sample. The usefulness of this novel approach is demonstrated by using it to determine the binding parameters of some selected drugs to human serum albumin. These parameters are subsequently used to calculate albumin, free drug, and total drug concentrations from unknown mixtures. The results are in good agreement with previously published data. Quantification of the amount of ligand extracted by SPME is done by liquid chromatography coupled with tandem mass spectrometry.

Cell Extracts↗