PubMed Health⌕ Search

Biomedical subjects

Jarmo Ruohonen

Publications and source records attributed to Jarmo Ruohonen.

3 recordsLinked to original sources

Somatotopic blocking of sensation with navigated transcranial magnetic stimulation of the primary somatosensory cortex.

We demonstrate that spatially accurate and selective stimulation is crucial when cortical functions are studied by the creation of temporary lesions with transcranial magnetic stimulation (TMS). Previously, the interpretation of the TMS results has been hampered by inaccurate knowledge of the site and strength of the induced electric current in the brain. With a Navigated Brain Stimulation (NBS) system, which provides real-time magnetic resonance image (MRI)-guided targeting of the TMS-induced electric field, we found that TMS of a spatially restricted cortical S1 thenar area is sufficient to abolish sensation from a weak electric stimulation of the corresponding skin area. We demonstrate that with real-time navigation, TMS can be repeatably directed at millimeter-level precision to a target area defined on the MRI. The stimulation effect was temporally and spatially specific: the greatest inhibition of sensation occurred when TMS was applied 20 ms after the cutaneous test stimulus and the TMS effect was sensitive to 8-13 mm displacements of the induced electric field pattern. The results also indicate that TMS selectively to S1 is sufficient to abolish perception of cutaneous stimulation of the corresponding skin area.

Adult↗

Frequency-related effects in the optimization of coils for the magnetic stimulation of the nervous system.

Magnetic stimulation of the nervous system is a non-invasive technique with a large number of applications in neurological diagnosis, brain research, and, recently, therapy. New applications require engineering modifications in order to decrease power consumption and coil heating. This can be accomplished by optimized coils with minimized resistance. In this study the influence of some frequency-related effects (skin and proximity effect) on the coil resistance will be discussed, together with the role played by wire shape, wire section, and twisting effect. The results show that the coil resistance increases with frequency. As an example, for a 20-mm2 circular wire section, the skin effect in the typical frequency range of magnetic stimulator devices (2-4 kHz) increases the coil resistance up to about 45% with respect to its dc value. Moreover, the influence of the frequency is lower for flat wire sections and reasonably small helix twist angle of the coil.

Computer Simulation↗