Ventricular wall motion using three-dimensional imaging.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Jasbir Sra.
Explore the source record for details and available documents.
Atypical atrial flutter with two prior failed ablations, complicating surgically repaired sinus venosus atrial septal defect and partial anomalous pulmonary venous connection, mapped by noncontact and electroanatomic mapping, is described. Electroanatomic and noncontact mapping clearly identified a narrow zone of normal voltage and activation which was targeted, with successful termination of the arrhythmia.
Explore the source record for details and available documents.
BACKGROUND: Evidence that atrial fibrillation may begin in early stages from triggers or reentry circuits primarily in the left atrium suggests that the entire Maze 3 lesion pattern may be unnecessary. In the present study we describe a new left atrial lesion pattern for intraoperative linear ablation of chronic atrial fibrillation. METHODS: Endocardial radiofrequency ablation was performed on 12 dogs with chronic atrial fibrillation. Lesions to isolate pulmonary veins in pairs, the left atrial appendage, and connecting lesions between these structures were administered in a randomized approach. RESULTS: Twelve dogs were in chronic atrial fibrillation for 31 +/- 21 days before ablation. Atrial fibrillation was successfully ablated and rendered noninducible in all 12 dogs. All treatment failures observed with less than the full lesion pattern became a success when the remaining lesions were given. CONCLUSIONS: Atrial fibrillation ablation using this left atrial lesion pattern is highly successful in this model. This approach may have significant utility as a concomitant procedure for patients with atrial fibrillation undergoing mitral valve procedures.
Twenty-three patients underwent endocardial radiofrequency ablation of atrial fibrillation (AF) during mitral valve procedures with a previously described left atrial lesion pattern. A temperature-controlled 7-coil surgical probe delivered 60-second lesions at 80 degrees C. The left atrial appendage was oversewn after ablation. Ages ranged from 28 to 88 years. Nineteen patients had chronic AF that was present for over 1 year in 74%; 12 patients had rheumatic mitral stenosis. Mean left atrial diameter was 5.4 +/- 0.7 cm. There was 1 operative death unrelated to the ablation, and no strokes or ablation-related complications were observed. At mean follow-up of 32.5 weeks, 86% of the 22 survivors were in sinus rhythm. All 18 patients with left atrial diameter <6 cm are in sinus rhythm. All postoperative atrial flutter was transient, and no patients required subsequent transcatheter ablation. This lesion pattern is safe and effective when applied in the method described here. It appears to be a reasonable alternative to the complete Maze 3 lesion pattern in patients with mitral valve disease.
Explore the source record for details and available documents.