PubMed Health⌕ Search

Biomedical subjects

Jason Moore

Publications and source records attributed to Jason Moore.

6 recordsLinked to original sources

Moment-rotation responses of the human lumbosacral spinal column.

The objective of this study was to test the hypothesis that the human lumbosacral joint behaves differently from L1-L5 joints and provides primary moment-rotation responses under pure moment flexion and extension and left and right lateral bending on a level-by-level basis. In addition, range of motion (ROM) and stiffness data were extracted from the moment-rotation responses. Ten T12-S1 column specimens with ages ranging from 27 to 68 years (mean: 50.6+/-13.2) were tested at a load level of 4.0 N m. Nonlinear flexion and extension and left and right lateral bending moment-rotation responses at each spinal level are reported in the form of a logarithmic function. The mean ROM was the greatest at the L5-S1 level under flexion (7.37+/-3.69 degrees) and extension (4.62+/-2.56 degrees) and at the L3-L4 level under lateral bending (4.04+/-1.11 degrees). The mean ROM was the least at the L1-L2 level under flexion (2.42+/-0.90 degrees), L2-L3 level under extension (1.58+/-0.63 degrees), and L1-L2 level under lateral bending (2.50+/-0.75 degrees). The present study proved the hypothesis that L5-S1 motions are significantly greater than L1-L5 motions under flexion and extension loadings, but the hypothesis was found to be untrue under the lateral bending mode. These experimental data are useful in the improved validation of FE models, which will increase the confidence of stress analysis and other modeling applications.

Adult↗

Tapered cages in anterior lumbar interbody fusion: biomechanics of segmental reactions.

OBJECT: The aim of this study was to determine the in vitro biomechanical responses of lumbar spinal segments after implantation of tapered cages. METHODS: Range of motion (ROM)- and stiffness-related data were determined in 10 human cadaveric T12-S1 columns subjected to flexion, extension, and lateral bending modes before and after anterior lumbar interbody fusion in which stand-alone LT-CAGE devices were used. The overall column showed no significant changes in ROM or stiffness. At the instrumented level, stiffness increased significantly (p < 0.05) in flexion and lateral bending modes. Indications of instability in extension were present, but these values were not statistically significant. There was no evidence of adjacent-level instability at any level in any mode, except for the segment superior to the fixation level in flexion; here there was a significant increase in ROM (p < 0.05) and a decrease in stiffness. CONCLUSIONS: The anatomical conformity and bilateral placement of cages provide ample stability and rigidity at the treated level, comparable to that of other cage systems. Because hypermobility is traditionally related to early degenerative changes, the present results appear to suggest that cages do not significantly contribute to such alterations.

Adult↗

Amniotic fluid embolism.

INCIDENCE: Amniotic fluid embolism is a catastrophic syndrome that occurs during pregnancy or in the immediate postpartum period. Multiple case reports have described the clinical findings and have reported variable success with supportive care. There has been discrepancy with respect to the incidence and mortality of amniotic fluid embolism. One likely explanation for this inconsistency is the lack of sensitive and specific diagnostic studies to definitively identify cases of amniotic fluid embolism, leading to both over- and underreporting. Despite the variation in reported incidence and mortality, amniotic fluid embolism remains a life-threatening condition with significant morbidity and mortality for the pregnant woman. It is the fifth most common cause of maternal mortality in the world. DIAGNOSIS: The diagnosis of amniotic fluid embolism continues to be a clinical diagnosis and a diagnosis of exclusion based on the rapid development of a complex constellation of findings with sudden cardiovascular collapse, acute left ventricular failure with pulmonary edema, disseminated intravascular coagulation, and neurologic impairment. Given the significant morbidity and mortality associated with this condition, a high index of suspicion is warranted. Suspected risk factors have included tumultuous labor, trauma, multiparity, increased gestational age, and increased maternal age. However, many patients who develop amniotic fluid embolism have no obvious risk factors. MANAGEMENT: Patients with amniotic fluid embolus are best managed using a multidisciplinary approach. There are no pharmacologic or other therapies that prevent or treat the amniotic fluid embolism syndrome, and supportive care typically involves aggressive treatment of multiple types of shock simultaneously. In this article we discuss the clinical presentation of amniotic fluid embolism syndrome as well as current opinions regarding pathophysiology, diagnosis, and management.

Critical Care↗

Cutting edge: molecular portrait of human autoimmune disease.

Autoimmune diseases affect 3-5% of the population, are mediated by the immune response to self-Ags, and are characterized by the site of tissue destruction. We compared expression levels of >4,000 genes in PBMC of control individuals before and after immunization to those of individuals with four distinct autoimmune diseases. The gene expression profile of the normal immune response exhibits coordinate changes in expression of genes with related functions over time. In contrast, each individual from all autoimmune diseases displays a similar gene expression profile unrelated to the pattern of the immunized group. To our surprise, genes with a distinct expression pattern in autoimmunity are not necessarily "immune response" genes, but are genes that encode proteins involved in apoptosis, cell cycle progression, cell differentiation, and cell migration.

Adult↗