[Summary of the clinical studies reported in the scientific session of the American Heart Association 2005 (Dallas, Texas, USA, 13-16 November 2005)].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Javier Bermejo.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Diastolic suction is a major determinant of early left ventricular filling in animal experiments. However, suction remains incompletely characterized in the clinical setting. METHODS AND RESULTS: First, we validated a method for measuring the spatio-temporal distributions of diastolic intraventricular pressure gradients and differences (DIVPDs) by digital processing color Doppler M-mode recordings. In 4 pigs, the error of peak DIVPD was 0.0+/-0.2 mm Hg (intraclass correlation coefficient, 0.95) compared with micromanometry. Forty patients with dilated cardiomyopathy (DCM) and 20 healthy volunteers were studied at baseline and during dobutamine infusion. A positive DIVPD (toward the apex) originated during isovolumic relaxation, reaching its peak shortly after mitral valve opening. Peak DIVPD was less than half in patients with DCM than in control subjects (1.2+/-0.6 versus 2.5+/-0.8 mm Hg, P<0.001). Dobutamine increased DIVPD in control subjects by 44% (P<0.001) but only by 23% in patients with DCM (P=NS). DIVPDs were the consequence of 2 opposite forces: a driving force caused by local acceleration, and a reversed (opposed to filling) convective force that lowered the total DIVPD by more than one third. In turn, local acceleration correlated with E-wave velocity and ejection fraction, whereas convective deceleration correlated with E-wave velocity and ventriculo:annular disproportion. Convective deceleration was highest among patients showing a restrictive filling pattern. CONCLUSIONS: Patients with DCM show an abnormally low diastolic suction and a blunted capacity to recruit suction with stress. By raising the ventriculo:annular disproportion, chamber remodeling proportionally increases convective deceleration and adversely affects left ventricular filling. These previously unreported mechanisms of diastolic dysfunction can be studied by using Doppler echocardiography.
BACKGROUND: Ejection intraventricular pressure gradients are caused by the systolic force developed by the left ventricle (LV). By postprocessing color Doppler M-mode (CDMM) images, we can measure noninvasively the ejection intraventricular pressure difference (EIVPD) between the LV apex and the outflow tract. This study was designed to assess the value of Doppler-derived EIVPDs as noninvasive indices of systolic chamber function. METHODS AND RESULTS: CDMM images and pressure-volume (conductance) signals were simultaneously acquired in 9 minipigs undergoing pharmacological interventions and acute ischemia. Inertial, convective, and total EIVPD curves were calculated from CDMM recordings. Peak EIVPD closely correlated with indices of systolic function based on the pressure-volume relationship: peak elastance (within-animal R=0.98; between-animals R=0.99), preload recruitable stroke work (within-animal R=0.81; between-animals R=0.86), and peak of the first derivative of pressure corrected for end-diastolic volume (within-animal R=0.88; between-animals R=0.91). The correlation of peak inertial EIVPD with these indices was also high (all R>0.75). Load dependence of EIVPDs was studied in another 5 animals in which consecutive beats obtained during load manipulation were analyzed. During caval occlusion (40% EDV reduction), dP/dtmax, ejection fraction, and stroke volume significantly changed, whereas peak EIVPD remained constant. Aortic occlusion (40% peak LV pressure increase) significantly modified dP/dtmax, ejection fraction, and stroke volume; a nearly significant trend toward decreasing peak EIVPD was observed (P=0.06), whereas inertial EIVPD was unchanged (P=0.6). EIVPD beat-to-beat and interobserver variabilities were 2+/-12% and 5+/-11%, respectively. CONCLUSIONS: Doppler-derived EIVPDs provide quantitative, reproducible, and relatively load-independent indices of global systolic chamber function that correlate closely with currently available reference methods.
BACKGROUND: The aim of this study is to analyse spatial distribution of myocardial velocities (MV) and myocardial velocity gradient (MVG) with color M-mode Doppler tissue imaging (DTI) and to analyse the influence of age in such parameters. METHODS AND RESULTS: A prospective study including 66 healthy volunteers was carried out with color M-mode DTI. Postprocessing of images was performed using proprietary software allowing the division of the myocardial wall into subendocardium, mesocardium and subepicardium. MV corresponding to the three layers and MVG time curves were obtained and systolic, early diastolic and late diastolic peak values were identified. MV were highest in subendocardium in systole, protodiastole and telediastole compared to external layers. Protodiastolic peak MV decreased in all layers with age, but with a higher impact in the subendocardium (r = 0.72, b = 0.136 (IC 95% 0.107-0.164), p = 0.0005). Older age resulted in larger telediastolic peak MV, without significant differences among layers. Linear correlation between protodiastolic peak mitral flow and peak protodiastolic velocity was higher in endocardium than in other layers (r = 0.79, p = 0.0005). CONCLUSIONS: Color M-mode DTI multilayer analysis showed that endocardium is more susceptible to age-related changes involving diastolic function. This dependency on age should be considered when assessing MV in other clinical settings.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: All indices of aortic stenosis (AS) rely on measurements of mean transvalvular pressure gradient (DeltaP) and flow rate. Because the gradient is reversed during late ejection, the late systolic left ventricular (LV)-aortic pressure crossover may be an erroneous landmark of end-ejection. The aortic incisura should be a better reference to calculate indices of AS invasively. METHODS AND RESULTS: The accuracy of the pressure crossover and the incisura to define end-ejection was assessed in a chronic AS experimental model (9 dogs) with the use of an implantable flowmeter and Doppler echocardiography as reference. In 288 hemodynamic recordings analyzed (aortic valve area [AVA]: 0.74+/-0.46 cm2), ejection ended 37+/-29 ms after the pressure crossover but almost simultaneously with the incisura (2+/-17 ms). Pressure crossover error accounted for significant errors in the measurement of DeltaP (95% limits of agreement, +0 to +7 mm Hg) and AVA (-0.1 to +0.2 cm2). These errors were reduced to less than half with the use of the incisura to define end-ejection. Additionally, the agreement with Doppler-derived AS indices was best with use of the incisura. Pressure crossover error was maximal in situations of higher output, moderate orifice narrowing, higher arterial compliance, and lower vascular resistance. In 32 consecutive patients undergoing cardiac catheterization for AS, the pressure crossover induced a clinically important overestimation of the DeltaP from +22 to +50%. Errors in AVA estimation were considerably smaller (-2% to +6%) because of simultaneous and offsetting errors in the measurements of DeltaP and flow. CONCLUSIONS: The aortic incisura and not the second pressure crossover should be used to obtain invasive indices of AS.
OBJECTIVES: The study was designed to validate in vivo a new method to measure ejection intraventricular pressure gradients (IVPGs) by processing color M-mode Doppler data and to assess the effects of inotropic interventions on IVPGs in the clinical setting. BACKGROUND: In the absence of obstruction, ejection IVPGs cannot be estimated by Doppler using the simplified Bernoulli equation. METHODS: High-fidelity micromanometers were placed in the left ventricle of eight minipigs, and synchronic Doppler images and pressure signals were obtained during different hemodynamic conditions. Twenty healthy volunteers and 20 dilated cardiomyopathy patients were studied at baseline and during esmolol, dobutamine, and atropine infusion (only dobutamine in patients). RESULTS: Excellent agreement was observed between micromanometer and Doppler methods for measuring instantaneous pressure differences among the apex, the mid-cavity, and the outflow tract (R(intraclass) = 0.98, 0.81, 0.76, and 0.98 for the peak, time-to-peak, peak reverse, and time-to-peak reverse values, respectively; n = 810 beats). Error of the noninvasive method was -0.05 +/- 0.25 mm Hg for the peak pressure difference. Parametrical images demonstrated that IVPGs originate mainly in the mid-ventricle and then propagate to the outflow tract. Both the magnitude and the temporal course of IVPGs were different among volunteers and patients. Inotropic interventions induced significant changes in the apex-outflow tract pressure differences in both populations, whereas atropine had no effect on IVPGs. CONCLUSIONS: For the first time, ejection IVPGs can be accurately visualized and measured by Doppler-echocardiography. Important aspects of the dynamic interaction among myocardial performance, load mechanics, and ejection dynamics can be assessed in the clinical setting using this method.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
OBJECTIVES: The aim of our study was to assess whether left atrial appendage (LAA) ligation in patients undergoing mitral valve replacement is associated with the risk of future embolisms. BACKGROUND: Previous studies show that the LAA plays an important role in the development of intracardiac thrombus. According to this decisive role, LAA surgical closure in patients undergoing cardiac surgery may be an attractive choice for reducing stroke. METHODS: We retrospectively studied 205 patients with previous mitral valve replacement and referred for echocardiography study. Patients were excluded if other causes of systemic embolism were found. The main outcome measure was the occurrence of an embolic event. RESULTS: Ligation of LAA was performed in 58 patients. However, an incomplete ligation was verified in six patients. During a median time from valve replacement to echocardiography study of 69.4 months (1 to 329), 27 patients had an embolism. Multivariate analysis identified the absence of LAA ligation (odds ratio [OR] 6.7 [95% confidence interval [CI] 1.5 to 31.0]; p = 0.02) and the presence of left atrial thrombus as the only independent predictors of occurrence of an embolic event. Moreover, when the identification of an incomplete LAA ligation was considered together with the absence of LAA ligation, risk of embolism increased up to 11.9 x (OR 11.9 [95% CI 1.5 to 93.6]; p = 0.02). CONCLUSIONS: Our study shows that LAA ligation during surgery of mitral valve replacement, performed in a high-risk population, is consistent with a reduction of the risk of late embolism and supports this technique if a mitral valve replacement is indicated.
OBJECTIVES: This study was designed to assess which hemodynamic index best accounts for clinical severity of aortic stenosis (AS) and to analyze the value of low-dose dobutamine testing. BACKGROUND: Pressure gradient and valve area are suboptimal because they depend on flow rate, correlate poorly with symptoms, and provide limited prognostic information. Recently, new indices and low-dose inotropic stimulation have been introduced, but their clinical value remains uncertain. METHODS: A total of 307 consecutive patients with AS were included in an ambispective study design (71 +/- 12 years old; peak jet velocity: 3.7 +/- 1.1 m/s). Clinical and Doppler-echocardiographic data were obtained, as well as results of low-dose dobutamine infusion (47 patients). Using receiver-operator-characteristic curve analysis, we evaluated jet velocity, pressure gradient, valve area, resistance, stroke-work loss (SWL), and dobutamine-induced increase in area for predicting 1) symptomatic status at entry, 2) early (</=3 months) cardiovascular death or aortic valve replacement, and 3) long-term outcome. Logistic regression and Cox models were designed multivariate and adjusted by bootstrapping. RESULTS: Only 28% of patients were alive without valve replacement at the end of the follow-up period (22 +/- 4 months). The decision for valve replacement was made by the referring physician, blinded to the SWL, valve resistance, and dobutamine results. Non-flow-corrected indices performed better than valve area and valve resistance. Among them, SWL best predicted the defined end points. Odds/hazard ratios associated with a SWL Delta = 17% were 5.14 for presenting AS symptoms, 4.68 for early events, and 2.31 for late outcome. A cutoff value of SWL >25% best discriminated clinical end points. Other independent predictors of prognosis were symptomatic status and left ventricular ejection fraction. Dobutamine testing added no value to baseline models. CONCLUSIONS: Non-flow-corrected indices show the highest clinical efficacy in aortic stenosis. Among these, SWL best predicts symptomatic status and outcome and therefore should be incorporated to aid patient management in unclear situations.
Explore the source record for details and available documents.