Nonexcitatory, cardiac contractility modulation electrical impulses: feasibility study for advanced heart failure in patients with normal QRS duration.

BACKGROUND: Cardiac contractility modulation signals are associated with acutely improved hemodynamics, but chronic clinical impact is not defined. OBJECTIVES: The purpose of this randomized, double-blind, pilot study was to determine the feasibility of safely and effectively delivering cardiac contractility modulation signals in patients with heart failure. METHODS: Forty-nine subjects with ejection fraction <35%, normal QRS duration (105 +/- 15 ms), and New York Heart Association (NYHA) class III or IV heart failure despite medical therapy received a cardiac contractility modulation pulse generator. Patients were randomized to have their devices programmed to deliver cardiac contractility modulation signals (n = 25, treatment group) or to remain off (n = 24, control group) for 6 months. Evaluations included NYHA class, 6-minute walk, cardiopulmonary stress test, Minnesota Living with Heart Failure Questionnaire, and Holter monitoring. RESULTS: Although most baseline features were balanced between groups, ejection fraction (31.4% +/- 7.4% vs 24.9% +/- 6.5%, P = .003), end-diastolic dimension (52.1 +/- 21.4 mm vs 62.5 +/- 6.2 mm, P = .01), peak VO(2) (16.0 +/- 2.9 mL O(2)/kg/min vs 14.3 +/- 2.8 mL O(2)/kg/min, P = .02), and anaerobic threshold (12.3 +/- 2.5 mL O(2)/kg/min vs 10.6 +/- 2.4 mL O(2)/kg/min, P = .01) were worse in the treatment group than in the control group. Nevertheless, one death occurred in the control group, and more patients in the treatment group were free of hospitalization for any cause at 6 months (84% vs 62%). No change in ectopy was observed. Compared with baseline, 6-minute walk (13.4 m), peak VO(2) (0.2 mL O(2)/kg/min), and anaerobic threshold (0.8 mL O(2)/kg/min) increased more in the treatment group than in control. None of these differences were statistically significant (small sample size). NYHA and Minnesota Living with Heart Failure Questionnaire changed similarly in the two groups. CONCLUSION: Despite a sicker population in the treatment group, no specific safety concerns emerged with chronic cardiac contractility modulation signal administration. Further study is required to definitively define the safety and efficacy of cardiac contractility modulation signals.

Aged↗

Evidence for longitudinal and transverse fiber conduction in human pulmonary veins: relevance for catheter ablation.

BACKGROUND: Segmental ostial ablation of the pulmonary veins (PVs) allows for successful control of paroxysmal atrial fibrillation in many patients. We hypothesized that mapping of the left atrial-PV junction with a 64-electrode basket catheter would allow characterization of conduction patterns that would identify sites where ablation is required to electrically isolate the PV. METHODS AND RESULTS: A 64-electrode basket catheter was used to map the PVs of 50 patients undergoing PV isolation procedures for the treatment of atrial fibrillation. Activation along each spline was classified as reflecting either longitudinal, transverse, or no activation. A longitudinal activation pattern recorded along a spline during sinus rhythm in right-sided PV and during CS pacing in left-sided PV before the delivery of any RF energy application had a sensitivity and specificity for a required ostial ablation site of 83% and 82%, respectively. When longitudinal activation along the spline was present during preablation recordings in both sinus rhythm and CS pacing, the sensitivity and specificity were 92% and 90%, respectively. A longitudinal activation pattern after the first RF application that produced a change in PV activation sequence had a sensitivity and specificity for sites where further ablation was required of 91% and 94%, respectively. CONCLUSIONS: Mapping of PV activation with a 64-electrode basket catheter allows characterization of conduction patterns that predict requirement for ablation. The presence of a longitudinal activation pattern is a strong predictor of ostial sites where ablative energy is required to electrically isolate the PV.

Atrial Fibrillation↗

Identification of transmural necrosis along a linear catheter ablation lesion during atrial fibrillation and sinus rhythm.

BACKGROUND: Determining whether a linear catheter radio frequency (RF) ablation lesion is transmural may be difficult, especially during atrial fibrillation. We hypothesized that changes in pacing thresholds and electrogram amplitude during atrial fibrillation and sinus rhythm could be used to assess whether a radiofrequency ablation resulted in transmural necrosis. METHODS: A hexapolar, linear, RF ablation catheter was positioned between the caval veins in the right atrium of seven sheep. Pacing thresholds and electrogram amplitudes during atrial fibrillation and sinus rhythm were measured before and after the application of RF energy. Sites along the linear lesion were assessed histologically. RESULTS: The electrogram amplitude in atrial fibrillation decreased significantly more at transmural sites (unipolar recording: 33 +/- 11% transmural vs. 22 +/- 13% non-transmural, p < or = 0.01; bipolar recording: 62 +/- 9% transmural vs. 43 +/- 15% non-transmural, p < or = 0.01). The electrogram amplitude in sinus rhythm decreased significantly more at transmural sites (unipolar recording: 49 +/- 18% transmural vs. 15 +/- 20% non-transmural, p < 0.001; bipolar recording: 63 +/- 17% transmural vs. 42 +/- 19% non-transmural, p = 0.002). The pacing threshold increased significantly more at sites with transmural necrosis (unipolar: increased by 378 +/- 103% transmural vs. 207 +/- 93% non-transmural, p < 0.001; bipolar: 370 +/- 80% transmural vs. 259 +/- 60% non-transmural, p < 0.001). CONCLUSIONS: The amplitude of the atrial electrogram from an ablation catheter can be used to discriminate areas with transmural necrosis from those without transmural necrosis during either atrial fibrillation or sinus rhythm. Termination of atrial fibrillation may not be necessary to estimate the histologic characteristics of an ablation lesion.

Animals↗