PubMed Health⌕ Search

Biomedical subjects

Jay Basillote

Publications and source records attributed to Jay Basillote.

6 recordsLinked to original sources

Third Prize: Comparison of radical nephrectomy, laparoscopic microwave thermotherapy, cryotherapy, and radiofrequency ablation for destruction of experimental VX-2 renal tumors in rabbits.

BACKGROUND AND PURPOSE: Currently available minimally invasive renal tumor-ablation procedures include cryotherapy, radiofrequency ablation, and microwave thermotherapy. In this study, we investigated the ability of these three approaches to destroy experimental renal tumors in rabbits. The mechanism of potential tumor metastasis was also explored. MATERIALS AND METHODS: The VX-2 tumor line is an aggressive rabbit epidermoid tumor with a high metastatic potential. An initial experiment comparing cooled-tip microwave thermotherapy with cryotherapy and radical nephrectomy for treatment of small VX-2 tumors revealed that all microwave-treated rabbits had local recurrence and that several also had diffuse intraperitoneal carcinomatosis. In view of these results, a second experiment was performed in which 45 New Zealand White rabbits were implanted laparoscopically with VX-2 xenografts underneath the kidney capsule and divided into five groups of 9 each. The test groups were microwave thermotherapy with a 3.5-mm cooled-tip probe, microwave thermotherapy with a 3.5-mm noncooled- tip probe, radiofrequency ablation with a 1.5-mm cooled-tip probe, radiofrequency ablation with a 1.5- mm non-cooled tip probe, and cryotherapy with a 2.3-mm cryoprobe. The control groups were five rabbits that were not treated, five rabbits with tumors that had the tumor pierced with a probe but were untreated, and five rabbits that underwent nephrectomy after piercing of the tumor. Treatment was initiated 5 days after tumor implantation. One month later, all animals were euthanized and autopsied. RESULTS: At 5 days after tumor implantation, laparoscopic inspection revealed no visible peritoneal metastases. At 1 month, in the cooled and non-cooled microwave-thermotherapy groups, carcinomatosis occurred in five and six of nine animals, respectively. In comparison, carcinomatosis was detected in two of nine animals in the cryotherapy group at autopsy. With respect to cooled and non-cooled radiofrequency ablation, carcinomatosis was observed in four of nine rabbits in each group. In the control groups, none of the animals with unpierced tumors exhibited carcinomatosis, while carcinomatosis was seen in two of the five rabbits with tumor violated by piercing and in three of the five rabbits that underwent immediate nephrectomy after piercing of the tumor. CONCLUSION: Carcinomatosis occurred most frequently in animals treated with microwave thermotherapy, followed by radiofrequency ablation, and lastly cryoablation. The simple act of piercing a highly aggressive tumor can result in local spread. More disconcerting, and less well understood, is why certain ablative modalities appear to increase the rate of intraperitoneal spread.

Animals↗

What happens to hemostatic agents in contact with urine? An in vitro study.

BACKGROUND AND PURPOSE: As the indications for topical hemostatic agents increase in urology, the question arises: what happens to these agents when they enter the urinary collecting system? To answer this question, we performed a series of in-vitro experiments mixing three hemostatic agents with normal and sanguineous urine. MATERIALS AND METHODS: Four commercially available topical hemostatic products: oxidized regenerated cellulose (Surgicel; Ethicon, Somerville, NJ), fibrin sealant (Tisseel VH Kit; Baxter Health Care Corporation, Irvine, CA), gelatin matrix hemostatic sealant (FloSeal; Baxter Health Care), and polyethylene glycol (CoSeal; Cohesion Technologies, Palo Alto, CA) were studied. Human urine (10 mL) was added to samples of each substance; this was done in triplicate. The 12 sample tubes were then capped and placed on a tube shaker at slow speed and 37 degrees C. Observations regarding consistency of the material were made at 6, 12, 24, 48, 72, 96, and 120 hours (5 days). Gelatin matrix hemostatic sealant was further tested in urine with various amounts of blood or blood clot; observations were again recorded out to 5 days. RESULTS: Surgicel maintained its solid form when it initially came in contact with urine, but over a period of 5 days, it transformed into a mucoid substance with visible free-floating fibers. It did not dissolve completely in urine within 5 days. Gelatin matrix was immediately transformed by urine into a fine colloidal suspension that did not change over the 5 days of the study. Fibrin glue, after mixing of the two components (fibrinogen and thrombin) directly in the urine, and polyethylene glycol immediately formed a solid clot at the bottom of the test tube on contact with the urine. When the mixture of fibrin sealant was allowed to form for 15 minutes and then added to urine, it again maintained a solid form. After 72 hours, the fibrin glue became a semisolid gelatinous plug. On analysis at 5 days, the fibrin sealant clot had transformed into a cohesive mucoid gel, and the polyethylene glycol clot had not changed. The gelatin matrix hemostatic sealant, when in contact with blood or blood clot, appeared to either become part of a clot or to remain in a colloidal suspension. At 5 days, all clots had dissolved to fine particulate suspensions, and the gelatin matrix appeared as a fine suspension. CONCLUSION: Fibrin glue and oxidized regenerated cellulose maintain a solid form when initially placed in direct contact with urine and then assume a semisolid gelatinous state, which is still present at 5 days. Polyethylene glycol forms a solid clot initially and does not change after 5 days. Only hemostatic gelatin matrix remained as a fine particulate suspension in both normal and sanguineous urine. The implications of these findings with regard to sealing the renal parenchyma or small violations of the collecting system after percutaneous or laparoscopic surgery await in-vivo testing.

Blood Loss, Surgical↗

Comparison of flexible ureteroscopes: deflection, irrigant flow and optical characteristics.

PURPOSE: We measured and compared the deflection, irrigation flow rates, distortion, resolution and light transmission of new generation flexible ureteroscopes. MATERIALS AND METHODS: Multiple characteristics of 5 flexible ureteroscopes (ACMI DUR-8 Elite, Olympus URF-P3, Storz 11278AU1 [Flex-X], Wolf 7330.072 and Wolf 7325.172) commonly available in the market were measured and compared. Measured data included active deflection, irrigation flow rates and optical characteristics. Each ureteroscope was evaluated with an empty working channel and with various accessories. Optical characteristics, specifically resolution and distortion, were measured using test targets (Edmund Optics, Barrington, New Jersey). Light transmission was also measured from the ureteroscope tip at 50% and 100% intensity. All 5 flexible ureteroscopes were tested in a laboratory setting using a Storz OR 1 system to capture the images. RESULTS: For all 5 ureteroscopes the angle of deflection was most impaired by a 365 microm laser fiber probe and least impaired by a 2.2Fr nitinol basket. Among all 5 ureteroscopes irrigation flow rate was most impaired with a 3.0Fr basket and least impaired with 200 microm laser fiber. The Wolf 7325.172 had the highest observed resolution of 25.39 lines per mm and the Wolf 7330.072 had the lowest distortion at 11.9%. The Karl Storz Flex-X and the ACMI DUR-8 Elite had the highest light output at 374 and 364 mV, respectively. CONCLUSIONS: The various flexible ureteroscopes differ with regard to flow rates as well as degree of deflection with either an empty or an occupied working channel. The Wolf flexible ureteroscope with a slightly larger working channel and a fused quartz bundle provided for superior flow and better optical performance. However, the greatest amount of tip deflection and highest light output were found in the ACMI and Karl Storz flexible ureteroscopes.

Artifacts↗

One-knot pyeloplasty.

Laparoscopic pyeloplasty represents one of the more advanced reconstructive procedures for the urologist. While early reports were replete with long operative times, there have been several changes that have added to the efficiency of the procedure. In our practice, we have found three changes to be of greatest value: (1) an upper-midline port placement; (2) use of a continuous suture for the anastomosis with a double-armed, knotted suture; and (3) antegrade stent placement.

Humans↗

Sealing percutaneous nephrolithotomy tracts with gelatin matrix hemostatic sealant: initial clinical use.

PURPOSE: Tubeless percutaneous nephrolithotomy (PCNL) has been performed at several centers with good success. However, these cases have been carefully selected with regard to short duration and smaller stone burden to prevent complications associated with the loss of access to the collecting system. We describe the use of gelatin matrix hemostatic sealant (FloSeal Baxter Medical, Fremont, California) as an adjunct to tubeless percutaneous nephrolithotomy to help preclude bleeding complications. MATERIALS AND METHODS: Two patients were treated with PCNL through a single nephrostomy tract. At the satisfactory conclusion of the cases the tract was occluded retrograde with an occlusion balloon catheter and gelatin matrix hemostatic sealant was injected down the nephrostomy tract. An indwelling stent and bladder catheter were placed following which all guidewires were removed and skin sutures were placed. RESULTS: The operative times were 75 and 180 minutes, respectively. Both patients had stable postoperative hemoglobin and no evidence of bleeding or obstruction on postoperative computerized tomography. CONCLUSIONS: Injection of gelatin matrix hemostatic sealant into the nephrostomy tract may be of value in preventing bleeding after PCNL. In this pilot experience it provided immediate and effective hemostasis.

Female↗

Current trends in urologic laparoscopic surgery.

PURPOSE: We examined the status of laparoscopy in urology and the impact of residency and fellowship training on the performance of laparoscopy as primary surgeon. We also examined whether performing nonsurgical tasks requiring two-handed dexterity had any link to the adoption of laparoscopic techniques by urologists. MATERIALS AND METHODS: A total of 8760 laparoscopy questionnaires containing 135 queries were mailed to urologists listed on the American Urological Association practicing urologists mailing list. The questions sought information on area of practice, time in practice, fellowship training, ambidexterity, laparoscopic experience, and experience with robotics. The response rate was 1.8% (155 of 8760). RESULTS: There appeared to be no significant correlation between the performance of laparoscopic surgery and participation in activities requiring bimanual dexterity. However, a correlation of strong statistical significance did exist between laparoscopic residency training and performance of laparoscopy after residency (p=0.003. There also was a correlation between fellowship training in laparoscopy/endourology and doing laparoscopy as primary surgeon. CONCLUSIONS: Participation in laparoscopic surgery during residency training is a major determining factor in performance of laparoscopy as a primary surgeon in practice. Younger surgeons trained in laparoscopy during residency are performing more laparoscopy post residency than those without laparoscopic training during residency. At present, there is a need to train more urologists in laparoscopy at the postgraduate level.

Adult↗