PubMed Health⌕ Search

Biomedical subjects

Jay D Keener

Publications and source records attributed to Jay D Keener.

2 recordsLinked to original sources

Long-term function after Charnley total hip arthroplasty.

The purpose of this study was to report the functional results and mortality rates of a consecutive series of patients younger than 50 years after Charnley total hip arthroplasty. The original group of 69 patients (93 hips) was followed up until death or a minimum of 25 years after surgery. Of the original 93 hips, 29 had been revised at some point. Functional outcomes included the Short Form-36, Western Ontario and McMaster University University Osteoarthritis Index (WOMAC), 6-minute walk distance, Noyes activity scale, and Harris hip scores and included followup in 42 of 43 living patients. The functional outcome of patients was good, with comparable Short Form-36 scores compared with normative values of healthy age-matched subjects. The 6-minute walk distances and WOMAC scores were slightly lower than healthy normatives but were thought to be influenced by medical comorbidities. Although comorbid medical and musculoskeletal conditions significantly hindered most measures of function, revision surgery or radiographic loosening of components had no significant influence on function. The mortality rates of this cohort of patients were similar to normative values at both 10 and 25 years after surgery.

Adult↗

Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old: a concise follow-up of a previous report.

We report the updated results for a previously evaluated cohort of patients who were less than fifty years old when they underwent Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three total hip arthroplasties performed in sixty-nine patients. The patients were followed for a minimum of twenty-five years after surgery or until death. The present report describes the findings of the radiographic and functional follow-up, which was performed for forty-two of the forty-three living patients. At the time of the latest follow-up, twenty-nine (31%) of the ninety-three total hip replacements had been revised or removed. Eighteen acetabular and five femoral components were revised secondary to aseptic loosening. The combined prevalence of radiographic failure or revision because of aseptic loosening was 13% for the femoral components and 34% for the acetabular components. Comorbid medical conditions significantly hindered results on each functional subscale (p < 0.05). This study demonstrates the durability of cemented total hip replacements in a young patient population. Sixty-nine percent of the original hip replacements were functioning well at the latest follow-up examination or at the time of death, and only 5% required more than one revision arthroplasty.

Adolescent↗