PubMed Health⌕ Search

Biomedical subjects

Jay S Epstein

Publications and source records attributed to Jay S Epstein.

9 recordsLinked to original sources

Nationwide outbreak of red eye syndrome associated with transfusion of leukocyte-reduced red blood cell units.

OBJECTIVE: To characterize red eye reactions occurring within 24 hours after receipt of units of leukocyte-reduced red blood cells, determine their etiology, and investigate their potential link to transfusion. METHODS: We conducted a survey of transfusion facilities nationwide to determine the scope and magnitude of the reactions; performed case-control and cohort studies among transfused patients at the facility where most reactions occurred; and performed animal experiments, using cellulose acetate derivatives extracted from leukocyte-reduction filters and filter precursors, to reproduce reactions. RESULTS: From January 1, 1997, through January 15, 1998, we identified 159 reactions in 117 patients from 17 states. Reactions were characterized by conjunctival erythema or hemorrhage (in 100% of patients), eye pain (in 62%), photophobia (in 46%), and decreased visual acuity (in 32%). Symptom onset occurred 1-24 hours after initiation of transfusion and resolved within a median of 5 days. Reactions were associated with transfusion sessions that included units of red blood cells filtered with a specific brand of filter, the LeukoNet filter (HemaSure) (odds ratio, 100.4; P<.001). There was a dose-response relationship between the number of LeukoNet-filtered units transfused and the attack rate for reactions, ranging from 0.8% among sessions in which 1 unit was transfused to 27.3% among sessions in which 3 or more units were transfused (P<.001). A similar ocular syndrome was elicited in rabbits injected with cellulose acetate derivatives extracted from unused LeukoNet filters or filter precursors. No reactions were reported after LeukoNet filters were withdrawn from the market. CONCLUSIONS: This transfusion-associated red eye syndrome was linked to a specific brand of leukocyte-reduction filter and likely resulted from cellulose acetate derivatives leached from the filter membrane.

Animals↗

Potential use of the scan statistic for quality control in blood product manufacturing.

There are minimal standards for the processing of whole blood components, and to apply those standards requires a system of quality assurances. Excessive indications of failures in compliance trigger inspections and other remedial actions, but the demarcation of what is excessive is a critical issue. Issues of low volume in some production facilities, low expected frequency of nonconformance, multiple nonindependent statistical tests, and controlling both the false-positive and false-negative rates all complicate quality assurance procedures. The scan statistic is a statistic that computes the number of events in a moving window throughout the period of risk. Monitoring plans based on scan statistics are developed to estimate the probability that a process that is under control.

Algorithms↗

Comparative sensitivity of HBV NATs and HBsAg assays for detection of acute HBV infection.

BACKGROUND: A study was designed to estimate relative analytic sensitivity and window-period (WP) closure and to project incremental yield of newer HBsAg tests, pooled-sample NAT, and single-sample NAT, compared to currently licensed HBsAg tests. STUDY DESIGN AND METHODS: HBV DNA and HBsAg test results for 23 HBV seroconversion (SC) panels were first analyzed to construct a model of primary HBV viremia. One-hundred representative samples were then selected from 10 panels and coded with 28 analytical controls. All 128 samples were tested by seven HBsAg tests and by four pooled-sample and three single-sample NAT assay formats. Results were analyzed to obtain differential times to HBV detection and combined with HBV incidence rates to project comparative yields. RESULTS: HBV doubling time during the ramp-up phase was estimated at 2.56 days. HBsAg concentrations at cutoff for new tests ranged from 0.07 to 0.12 ng per mL, compared with 0.13 to 0.62 ng per mL for licensed tests. Estimated viral load at cutoff ranged from 102 to 267 IU per mL for new tests and from 363 to 1069 IU per mL for licensed tests. HBsAg tests detected 31 to 63 percent of early ramp-up phase samples in the 100-member seroconversion panel study, while pooled-sample NAT detected 55 to 71 percent and single-sample NAT, 82 to 99 percent. Compared with currently licensed HBsAg assays, newer HBsAg assays would reduce the WP by 2 to 9 days; pooled-sample NAT would reduce the WP by 9 to 11 days; and single-sample NAT would reduce the WP by 25 to 36 days. CONCLUSION: Newer HBsAg tests would be expected to detect an additional 15 to 21 infected units per 107 donations, compared to licensed HBsAg tests. Sensitivity, WP closure, and yield projections for newer HBsAg assays and pooled-sample NAT are comparable. Single-sample NAT would increase yield by 13 to 15 units per 107 donations over pooled-sample NAT and newer HBsAg assays and by 35 to 50 units per 107 donations over currently licensed HBsAg assays.

Acute Disease↗

Management of severe VWD with cryoprecipitate collected by repeated apheresis of a single dedicated donor.

BACKGROUND: Rare and severe forms of VWD are associated with trace or absent VWF. The feasibility of supporting a child with severe VWD from birth through age 12 with cryoprecipitate derived from DDAVP-stimulated plasma exchange of a single dedicated donor is reported. STUDY DESIGN AND METHODS: An infant with excessive hemorrhage at circumcision was found to have Type 3 VWD. His father carried an allele with a mutation at the level of VWF mRNA expression but did not have a history of bleeding. Cryoprecipitate was prepared from serial DDAVP-stimulated plasma exchanges of the father. RESULTS: Repeated plasma-exchange donations were performed to provide all of the VWF needed for his son. An average of 14 cryoprecipitate units was prepared from each donation, and the units contained markedly elevated levels of FVIII:C. The cryoprecipitate was stored for up to 102 months. Components tested after more than 8 years of storage showed 48 to 130 percent of original FVIII:C activity. Ninety-seven percent of the bleeding episodes, such as epistaxis, tongue-biting accidents, and other minor lacerations, were successfully managed with a single 50- to 100-percent replacement dose of FVIII. The patient experienced normal growth and development and is free of any long-term sequelae attributable to his disease. CONCLUSIONS: Cryoprecipitate prepared by repeated plasma exchange of a VWD carrier provided excellent hemostatic function, even after storage intervals of more than a year. Plasma exchange of a committed donor was a cost-effective and safe option for long-term management of VWD.

Blood Component Removal↗

Bacterial contamination of blood components: risks, strategies, and regulation: joint ASH and AABB educational session in transfusion medicine.

Bacterial contamination of transfusion products, especially platelets, is a longstanding problem that has been partially controlled through modern phlebotomy practices, refrigeration of red cells, freezing of plasma and improved materials for transfusion product collection and storage. Bacterial contamination of platelet products has been acknowledged as the most frequent infectious risk from transfusion occurring in approximately 1 of 2000-3000 whole-blood derived, random donor platelets, and apheresis-derived, single donor platelets. In the US, bacterial contamination is considered the second most common cause of death overall from transfusion (after clerical errors) with mortality rates ranging from 1:20000 to 1:85000 donor exposures. Estimates of severe morbidity and mortality range from 100 to 150 transfused individuals each year. Concern over the magnitude and clinical relevance of this issue culminated in an open letter calling for the "blood collection community to immediately initiate a program for detecting the presence of bacteria in units of platelets." Thereafter, the American Association of Blood Banks (AABB) proposed new standards to help mitigate transfusion of units that were contaminated with bacteria. Adopted with a final implementation date of March 1, 2004, the AABB Standard reads "The blood bank or transfusion service shall have methods to limit and detect bacterial contamination in all platelet components." This Joint ASH and AABB Educational Session reviews the risks, testing strategies, and regulatory approaches regarding bacterial contamination of blood components to aid in preparing practitioners of hematology and transfusion medicine in understanding the background and clinical relevance of this clinically important issue and in considering the approaches currently available for its mitigation, as well as their implementation. In this chapter, Drs. Hillyer and Josephson review the background and significance of bacterial contamination, as well as address the definitions, conceptions and limitations of the terms risk, safe and safety. They then describe current transfusion risks including non-infectious serious hazards of transfusion, and current and emerging viral risks. In the body of the text, Dr. Blajchman reviews the prevalence of bacterial contamination in cellular blood components in detail with current references to a variety of important studies. He then describes the signs and symptoms of transfusion-associated sepsis and the sources of the bacterial contamination for cellular blood products including donor bacteremia, and contamination during whole blood collection and of the collection pack. This is followed by strategies to decrease the transfusion-associated morbidity/mortality risk of contaminated cellular blood products including improving donor skin disinfection, removal of first aliquot of donor blood, pre-transfusion detection of bacteria, reducing recipient exposure, and pathogen reduction/inactivation. In the final sections, Drs. Vostal, Epstein and Goodman describe the regulations and regulatory approaches critical to the appropriate implementation of a bacterial contamination screening and limitation program including their and/or the FDA's input on prevention of bacterial contamination, bacterial proliferation, and detection of bacteria in transfusion products. This is followed by a discussion of sampling strategy for detection of bacteria in a transfusion product, as well as the current approval process for bacterial detection devices, trials recommended under "actual clinical use" conditions, pathogen reduction technologies, and bacterial detection and the extension of platelet storage.

Bacterial Infections↗