White matter tractography using diffusion tensor deflection.

Diffusion tensor MRI provides unique directional diffusion information that can be used to estimate the patterns of white matter connectivity in the human brain. In this study, the behavior of an algorithm for white matter tractography is examined. The algorithm, called TEND, uses the entire diffusion tensor to deflect the estimated fiber trajectory. Simulations and imaging experiments on in vivo human brains were performed to investigate the behavior of the tractography algorithm. The simulations show that the deflection term is less sensitive than the major eigenvector to image noise. In the human brain imaging experiments, estimated tracts were generated in corpus callosum, corticospinal tract, internal capsule, corona radiata, superior longitudinal fasciculus, inferior longitudinal fasciculus, fronto-occipital fasciculus, and uncinate fasciculus. This approach is promising for mapping the organizational patterns of white matter in the human brain as well as mapping the relationship between major fiber trajectories and the location and extent of brain lesions.

Algorithms↗

The need for phase-encoding flow compensation in high-resolution intracranial magnetic resonance angiography.

PURPOSE: To demonstrate that the time delay between phase and frequency encoding and the presence of pulsatile blood flow in high-resolution time-of-flight (TOF) imaging of the intracranial arteries (especially near the circle of Willis) can distort the appearance of blood vessels and result in a cross-hatch-appearing artifact in surrounding tissue. MATERIALS AND METHODS: Two techniques to reduce the artifact, tri-directional flow compensation (3DFC) and elliptical-centric (EC) phase-encoding order, are investigated in five volunteer studies. RESULTS: 3DFC eliminates the pulsation-related artifacts and the vessel distortion. A residual amplitude variation artifact is observed. EC phase encoding nearly eliminates the pulsatile motion-related artifact, but it does not eliminate vessel distortion. CONCLUSION: The combination of 3DFC and EC phase encoding appears to provide the greatest artifact reduction in the five volunteer studies performed.

Adult↗

Improved efficiency in double-inversion fast spin-echo imaging.

Double-inversion fast spin-echo (FSE) pulse sequences can be designed to provide excellent suppression of blood signal in black-blood MRI. However, because a nonselective inversion is used, these sequences typically have been highly inefficient. In this work it is demonstrated that the efficiency of double-inversion sequences can be greatly improved by a form of interleaving in which all of the slices to be imaged in a single pass are reinverted each time a signal is obtained from any single slice. To date, several studies have demonstrated a high level of blood suppression with these more efficient techniques.

Aged↗

Reduction of flow-related signal loss in flow-compensated 3D TOF MR angiography, using variable echo time (3D TOF-VTE).

High-resolution MRA with phase/frequency flow compensation may require very long echo times (TEs). Variable TE (VTE) was implemented into flow-compensated 3D TOF to minimize the effective TE and reduce the flow-related signal void. The k-space of the 3D TOF was divided into segment groups ranging from two to 32 segments with different TEs. The TEs were minimized and the flow-compensation gradient lobes were calculated to null the total first moment at the peak of the echo for each segment. Possible artifacts and off-resonance effects were evaluated, with respect to the number of TE segments, using the point spread function (PSF) and corresponding experiments. The optimal number of TE segments for the least artifact was determined to be one-half of the number of slices. Two types of artifacts caused by VTE were predicted and subsequently observed. The developed pulse sequence 3D TOF-VTE was tested on clinical MRI systems, by performing scans of the cervical carotid artery and intracranial carotid artery at the carotid siphon. The signal distribution near the bifurcation and the siphon was much more uniform with VTE, and the flow-related signal loss was greatly reduced. The resultant MR angiograms provided improved vessel detail. The results show that VTE improved the quality of flow-compensated 3D TOF MRA.

Artifacts↗