Jean Hertzberg

Publications and source records attributed to Jean Hertzberg.

9 recordsLinked to original sources

Computational simulations of the total cavo-pulmonary connection: insights in optimizing numerical solutions.

The Fontan procedure is a palliative surgical technique that is used to treat patients with congenital heart defects that include complex lesions such as those with a hypoplastic ventricle. In vitro, in vivo, and computational models of a set of modifications to the Fontan procedure, called the total cavopulmonary connection (TCPC), have been developed. Using these modeling methods, attempts have been made at finding the most energy efficient TCPC circuit. Computational modeling has distinct advantages to other modeling methods. However, discrepancies have been found in validation studies of TCPC computational models. There is little in the literature available to help explain and correct for such discrepancies. Differences in computational results can occur when choosing between steady flow versus transient flow numerical solvers. In this study transient flow solver results were shown to be more consistent with results from previous TCPC in vitro experiments. Using a transient flow solver we found complex fluctuating flow patterns can exist with steady inflow boundary conditions in computational models of the TCPC. To date such findings have not been reported in the literature. Furthermore, our computational modeling results suggest fluctuating flow patterns as well as the magnitudes of these secondary flow structures diminish if the TCPC offset between vena cavae is increased or if flanged connections are added. An association was found between these modifications and improvements in TCPC circuit flow efficiencies. In summary, development of accurate computational simulations in the validation process is critical to efforts in finding the most efficient TCPC circuits, efforts aimed at potentially improving the long term outcome for Fontan patients.

Blood Flow Velocity↗

Numerical modeling of microbubble backscatter to optimize ultrasound particle image velocimetry imaging: initial studies.

We have developed a promising non-invasive ultrasound-based method for performing particle image velocimetry (PIV) in vivo. This method, termed echo PIV, provides multi-component blood velocity data with good ( approximately 2 ms) temporal resolution. The method takes advantage of the non-linear ultrasound backscatter characteristics of small gas-filled microbubbles (ultrasound contrast) that are seeded into the blood stream. In this study, we use a numerical model to explore potential areas to focus future work in echo PIV. Ultrasound backscatter from encapsulated microbubbles was modeled using a modified Rayleigh-Plesset equation (Church model, 1995), taking into account the protein/lipid shell layer as a thick, mass-conserving incompressible fluid surrounded by incompressible blood-like fluid. The equation of motion was solved numerically to characterize the fundamental and second harmonic components of the backscattered pressure. Results show a significant advantage in using the second harmonic component for echo PIV, especially for small bubble sizes less than 3 microm in diameter at 2.2 MHz frequency. The effect of the shell thickness ranging from 10 to 500 nm on the vibration amplitude of the bubble was examined and it is shown that the presence of the shell requires mechanical index (MI) > 0.2 of incident pressure amplitude to improve bubble detectability. Analysis of the effect of pulse length shows a tradeoff between axial resolution (short pulse length) and bubble detectability (longer pulse length) will most likely be required. The effect of varying MI between 0.1 and 0.6 was also studied at a center frequency of 2.2 MHz and the results indicate that the resonance of the second harmonic is maximized for bubbles with diameter of approximately 2.75 microm. Bubble non-linearities at MI > 0.2 induced a resonant frequency shift away from the integer multiple of the incident frequency in the second harmonic backscatter. For a given bubble size, there is a combination of optimal incident frequency and mechanical index range that maximizes the ratio of the second harmonic compared to the fundamental. This resonant frequency decreases with increasing bubble radius. Further, a narrow bandwidth pulse is shown to increase signal strength. Both of these effects may cause conflict with factors governing spatial resolution. Optimization of the incident frequency, microbubble size and mechanical index to enhance bubble detectability will depend on the particular clinical application. These theoretical predictions provide further understanding of the physics behind our echo PIV technique, and should be useful for guiding the design of echo PIV systems.

Blood Flow Velocity↗

Characterizing vortex ring behavior during ventricular filling with Doppler echocardiography: an in vitro study.

Doppler ultrasound color M-mode imaging (CMM) has been proposed as a noninvasive means of quantifying diastolic function by measuring flow propagation into the left ventricle. However, the relationship between CMM-derived parameters and underlying fluid dynamics is still unclear. The purpose of this study was to couple high-resolution velocimetry measurements with ultrasound Doppler and CMM measurements in order to shed light on the relationship between CMM flow propagation and inflow dynamics using a simple yet highly reproducible in vitro model of left ventricular inflow. Two Reynolds number conditions were analyzed: 4000 and 6000. Both conditions produced starting jets that formed vortex rings. Average (N = 5) CMM centerline velocities were in agreement with DPIV centerline velocities, although large uncertainty in CMM data was present (uncertainty +/- 10 cm s(-1)). Two flow propagation parameters were extracted from the CMM data: the first utilized an isovelocity as the marker of flow propagation; the second used local peak velocity as the marker. The isovelocity technique followed the flow proximal to the vortex (wavefront) while the peak velocity method followed peak vorticity, and therefore vortex propagation, closely. We conclude that CMM imaging, while limited in measuring absolute velocities, can be utilized to assess inflow vortex ring properties, and thereby provide useful information on diastolic function.

Blood Flow Velocity↗

Noninvasive measurement of steady and pulsating velocity profiles and shear rates in arteries using echo PIV: in vitro validation studies.

Although accurate measurement of velocity profiles, multiple velocity vectors, and shear stress in arteries is important, there is still no easy method to obtain such information in vivo. We report on the utility of combining ultrasound contrast imaging with particle image velocimetry (PIV) for noninvasive measurement of velocity vectors. This method (echo PIV) takes advantage of the strong backscatter characteristics of small gas-filled microbubbles (contrast) seeded into the flow. The method was tested in vitro. The steady flow analytical solution and optical PIV measurements (for pulsatile flow) were used for comparison. When compared to the analytical solution, both echo PIV and optical PIV resolved the steady velocity profile well. Error in shear rate as measured by echo PIV (8%) was comparable to the error of optical PIV (6.5%). In pulsatile flow, echo PIV velocity profiles agreed well with optical PIV profiles. Echo PIV followed the general profile of pulsatile shear stress across the artery but underestimated wall shear at certain time points. However, error in shear from echo PIV was an order of magnitude less than error from current shear measurement methods. These studies indicate that echo PIV is a promising technique for noninvasive measurement of velocity profiles and shear stress.

Animals↗

Study of in vitro mitral valve filling flow.

Diastolic function is a good indicator of overall cardiac health. This study is in support of a non-invasive technique to measure diastolic function. Interpretation of mitral flow, and early diagnosis of normality or dysfunction, can be enhanced by improved understanding of the fluid dynamics. A simple in-vitro model of mitral flow is being used to illustrate vortex dynamics associated with diastolic inflow. A range of tailored mitral flow waveforms are being developed to mimic normal velocity profiles. Laser Doppler velocimetry (LDV) is being used to measure the flow speed. By combining flow visualization, particle image velocimetry and LDV, vortex ring signatures including size, circulation, and propagation speed are being examined as possible metrics for diastolic dysfunction. The detection of these signatures in the downstream flow will be compared to clinical waveforms derived from Doppler ultrasound.

Blood Flow Velocity↗

Advantages in using multi-frequency driving ultrasound for optimizing echo particle image velocimetry techniques.

We have recently developed an ultrasound based velocimetry technique, termed echo particle image velocimetry (echo PIV). This method takes advantage of the non-linear backscatter characteristics of ultrasound contrast microbubbles when exposed to certain ultrasonic field. Preliminary in vitro, animal and clinical studies have shown significant promise of this method for measuring multiple velocity components with good temporal and spatial resolution. However, there is still difficulty in maximizing the non-linearity of bubble backscatter using conventional Gaussian-pulse excitation techniques because significant harmonic components may not be produced at modest pressure amplitudes and the higher incident pressure amplitudes required to induce non-linear behavior may cause bubble destruction. We present here a potential solution to this problem through the use of multi-frequency excitation. A rectangular pulse with multiple harmonics is used to drive the bubble. The backscatter process is studied through a modified Rayleigh-Plesset equation. Results show that the rectangular wave is effective in improving the visibility of microbubbles with ultrasound backscattered efficiency significantly higher than the widely used Gaussian waveform. Use of rectangular pulses with 4 and 2 harmonics showed no significant difference in bubble backscatter behavior, indicating that a two-frequency excitation may be sufficient to induce non-linear behavior of the microbubbles practically at modest incident pressures.

Algorithms↗

Regression analysis for vortex ring characteristics during left ventricular filling.

A new technique to determine ventricular function is being developed from non-invasive measurements of centerline mitral flow, using color M-mode (CMM) ultrasound. Based on the hypothesis that vortex rings accompanying mitral flow are significant indicators of ventricular filling, we present a technique to determine characteristics of vortex rings created by mitral inflow, including diameter, position and circulation from the CMM derived centerline velocity data. The rings are modeled as vortex filament loops, which induce axial flow. A quasi-Newtonian regression was performed on the velocity data to determine model ring characteristics. Performance of the technique was determined using a synthetic data set with known vortex ring parameters. The algorithm is shown to be insensitive to initial estimates for ring parameters. However, noise in the data can lead to inaccuracy in the derived ring parameters. Further work to increase the accuracy of the regression algorithm and decrease effect of data uncertainty is ongoing.

Blood Flow Velocity↗

Reverse flow in compliant vessels and its implications for the Fontan procedure: numerical studies.

The Total Cavopulmonary Connection (TCPC), a variant of the Fontan operation used for palliative cardiovascular repair of patients with single ventricle physiology, creates a passive system of blood flow into the pulmonary circulation for which energy efficiency may be critical to long term outcome. Clinical studies have shown that reverse flow in the TCPC is an indication of poor clinical status in these patients. Using numerical simulations, we demonstrate that reverse flow leads to increased energy losses in compliant vessels. Such an effect can potentially set off a series of spiraling negative events with decreased ventricular function leading to reverse flow, which causes decreased energy efficiency, which in turn leads to worsening function, and so forth, thereby suggesting one cause of progressive heart failure in this patient group.

Compliance↗

Initial experience with the development and numerical and in vitro studies of a novel low-pressure artificial right ventricle for pediatric Fontan patients.

The Fontan operation, an efficient palliative surgery, is performed for patients with single-ventricle pathologies. The total cavopulmonary connection is a preferred Fontan procedure in which the superior and inferior vena cava are connected to the left and right pulmonary artery. The overall goal of this work is to develop an artificial right ventricle that can be introduced into the inferior vena cava, which would act to reverse the deleterious hemodynamics in post-Fontan patients. We present the initial design and computational analysis of a micro-axial pump, designed with the particular hemodynamics of Fontan physiology in mind. Preliminary in vitro data on a prototype pump are also presented. Computational studies showed that the new design can deliver a variety of advantageous operating conditions, including decreased venous pressure through proximal suction, increased pressure rise across the pump, increased pulmonary flows, and minimal changes in superior vena cava pressures. In vitro studies on a scaled prototype showed trends similar to those seen computationally. We conclude that a micro-axial flow pump can be designed to operate efficiently within the low-pressure, low-flow environment of cavopulmonary flows. The results provide encouragement to pursue this design to for in vitro studies and animal studies.

Animals↗