Cardiopulmonary interactions in patients with heart failure.

PURPOSE OF REVIEW: The purpose of this review was to summarize recent findings concerning the consequences of cardiopulmonary interactions in acute cardiogenic pulmonary edema, weaning from mechanical ventilation and fluid-responsiveness assessment by respiratory variations of stroke volume. RECENT FINDINGS: The efficacy of continuous or bilevel positive airway pressure in patients with acute cardiogenic pulmonary edema was strongly suggested by two recent meta-analyses. There is growing evidence to suggest that weaning-induced cardiac dysfunction and acute cardiogenic pulmonary edema could explain a large amount of liberation failure from mechanical ventilation. Despite a potential role for echocardiography and plasma measurements of B-type natriuretic peptide in demonstrating a cardiac origin to weaning failure, the demonstration of a significant increase in pulmonary-artery occlusion pressure during the weaning trial remains the gold standard for this purpose. In patients with heart failure there is no evidence for revisiting the reliability of the respiratory variation of stroke-volume surrogates to predict fluid responsiveness. SUMMARY: For clinical practice, the knowledge of cardiopulmonary interactions is of paramount importance in understanding the crucial role of mechanical ventilation for treating patients with heart failure and, by contrast, the deleterious cardiovascular effects of weaning in patients with overt or hidden cardiac failure.

Acute Disease↗

Evaluation of a new invasive continuous cardiac output monitoring system: the truCCOMS system.

OBJECTIVE: To compare measurements of cardiac output using a new pulmonary artery catheter with those obtained using two "gold standard" methods: the periaortic transit time ultrasonic flow probe and the conventional pulmonary artery thermodilution. DESIGN: Prospective clinical trial. SETTING: Cardiac surgery operating room and surgical ICU in a university hospital. MATERIAL AND METHODS: In the operating room, a new pulmonary artery catheter (truCCOMS system) was inserted in eight patients. A periaortic flow probe was inserted in four of them. Measurements of cardiac output obtained with the truCCOMS catheter and with the flow probe were compared at different phases of the surgical procedure. In the intensive care unit, the cardiac output displayed by the truCCOMS monitor was compared with the value obtained after bolus injection performed subsequently. RESULTS: In the operating room (70 measurements), the coefficient of correlation between cardiac output measured by the flow probe and the truCCOMS system was r2 = 0.79, the bias was +0.11 l/min with a precision of 0.47 l/min, and limits of agreement -0.83 to +1.05 l/min. In the intensive care unit (108 measurements), the coefficient of correlation between cardiac output measured by thermodilution and the truCCOMS system was r2 = 0.56, the bias was -0.07 l/min, the precision was 0.66 l/min, and the limits of agreement were -1.39 to +1.25 l/min. CONCLUSION: The truCCOMS system is a reliable method of continuous cardiac output measurement in cardiac surgery patients.

Aorta↗

Value of the plasma protein and hemoglobin concentration in the diagnosis of pulmonary edema in scorpion sting patients.

OBJECTIVE: To investigate the value of measuring total plasma protein and hemoglobin concentrations for the diagnosis of pulmonary edema secondary to scorpion envenomation. DESIGN AND SETTING: Retrospective study over a 4-year period in the medical intensive care unit of a university hospital. PATIENTS: 67 patients older than 3 years admitted in the intensive care unit for scorpion envenomation and stratified into two groups according to the presence of pulmonary edema assessed by a medical committee that took into account clinical, radiological, and blood gas data at admission and after treatment. Total plasma protein and hemoglobin concentrations were analyzed separately. RESULTS: At admission all patients with and without pulmonary edema exhibited polypnea and tachycardia. The mean plasma protein and hemoglobin concentrations were higher in patients with pulmonary edema (74+/-6 and 14.2+/-2.0 g/dl, respectively) than in those without pulmonary edema (64+/-6 and 12.3+/-1.4 g/dl). After 24 h plasma protein and hemoglobin concentrations decreased in the pulmonary edema group (-11 and -1.9 g/dl) despite a negative fluid balance (-500 ml). A plasma protein concentration of 70 g/l or more predicted the presence of pulmonary edema with a sensitivity of 80% a specificity of 96%, a positive predictive value of 97%, and negative predictive value of 77%. CONCLUSIONS: In scorpion-envenomed patients with cardiorespiratory manifestations high plasma protein and hemoglobin concentrations suggest the presence of pulmonary edema.

Adolescent↗