PubMed Health⌕ Search

Biomedical subjects

Jean Meunier

Publications and source records attributed to Jean Meunier.

7 recordsLinked to original sources

Topographic screening of donor eyes for previous refractive surgery.

PURPOSE: To determine whether donor eyes had previous refractive surgery using Orbscan (Bausch & Lomb Surgical) corneal topography. SETTING: Lions Eye Bank of Oregon, Portland, Oregon, USA, and Maisonneuve-Rosemont, Hospital, Montreal, Quebec, Canada. METHODS: Orbscan corneal topographies of 50 donor eyes from the Lions Eye Bank of Oregon were obtained; 10 eyes had previous refractive surgery (6 laser in situ keratomileusis, 2 photorefractive keratectomy, 2 radial keratotomy) to correct myopia, and 40 had not had surgery. Algorithms based on corneal anterior and posterior elevations and anterior tangential curvature were developed: The difference in curvature (DC) was based on the difference in the mean anterior tangential curvature between central and midperipheral areas; difference in elevation (DE) represented the difference between the anterior and posterior central elevations. Receiver-operating characteristic (ROC) curves for each algorithm were obtained, and sensitivity values at fixed specificities were calculated. RESULTS: The mean area under the ROC curve, which corresponds to the probability of correctly identifying the presence of a previous refractive surgery, was 0.853 +/- 0.079 (SE) for DC and 0.933 +/- 0.057 for DE. The DC algorithm resulted in a sensitivity of 80% for a specificity of 87.5%, and DE yielded a sensitivity of 90% for a specificity of 92.5%. There was a strong correlation between the value of the DE and DC algorithms and the amount of previous refractive surgery (DC: r = 0.84, P = .008; DE: r = 0.76, P = .028). CONCLUSION: The results led to a proposed criteria-based system using Orbscan corneal topography to screen eye-bank eyes for previous refractive surgery.

Adult↗

Intravascular ultrasound image segmentation: a three-dimensional fast-marching method based on gray level distributions.

Intravascular ultrasound (IVUS) is a catheter based medical imaging technique particularly useful for studying atherosclerotic disease. It produces cross-sectional images of blood vessels that provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions as well as plaque shape and size. Automatic processing of large IVUS data sets represents an important challenge due to ultrasound speckle, catheter artifacts or calcification shadows. A new three-dimensional (3-D) IVUS segmentation model, that is based on the fast-marching method and uses gray level probability density functions (PDFs) of the vessel wall structures, was developed. The gray level distribution of the whole IVUS pullback was modeled with a mixture of Rayleigh PDFs. With multiple interface fast-marching segmentation, the lumen, intima plus plaque structure, and media layers of the vessel wall were computed simultaneously. The PDF-based fast-marching was applied to 9 in vivo IVUS pullbacks of superficial femoral arteries and to a simulated IVUS pullback. Accurate results were obtained on simulated data with average point to point distances between detected vessel wall borders and ground truth <0.072 mm. On in vivo IVUS, a good overall performance was obtained with average distance between segmentation results and manually traced contours <0.16 mm. Moreover, the worst point to point variation between detected and manually traced contours stayed low with Hausdorff distances <0.40 mm, indicating a good performance in regions lacking information or containing artifacts. In conclusion, segmentation results demonstrated the potential of gray level PDF and fast-marching methods in 3-D IVUS image processing.

Algorithms↗

Automatic 3D segmentation of intravascular ultrasound images using region and contour information.

Intravascular ultrasound (IVUS) produces images of arteries that show the lumen in addition to the layered structure of the vessel wall. A new automatic 3D IVUS fast-marching segmentation model is presented. The method is based on a combination of region and contour information, namely the gray level probability density functions (PDFs) of the vessel structures and the image gradient. Accurate results were obtained on in-vivo and simulated data with average point to point distances between detected vessel wall boundaries and validation contours below 0.105 mm. Moreover, Hausdorff distances (that represent the worst point to point variations) resulted in values below 0.344 mm, which demonstrate the potential of combining region and contour information in a fast-marching scheme for 3D automatic IVUS image processing.

Algorithms↗

Topography-based screening for previous laser in situ keratomileusis to correct myopia and hyperopia.

PURPOSE: To develop a screening tool based on corneal topography to detect previous myopic and hyperopic laser in situ keratomileusis (LASIK). METHODS: Clinical data from three private clinics were analyzed in a university setting. A total of 476 topographies (Orbscan II) were randomly selected (1 topography per patient): 338 from unoperated corneas, 81 from corneas that had LASIK to correct myopia, and 57 from corneas that had LASIK to correct hyperopia. The LASIK procedures were performed using a Technolas excimer laser (217C or 217Z) and a Hansatome microkeratome. The first set of algorithms (VESm and VESh) calculated the volume summation between the anterior corneal surface and the best-fit sphere in the central and mid-peripheral regions. The second set of algorithms (DCm and DCh) calculated the mean anterior tangential curvature difference between the central and mid-peripheral regions. RESULTS: The features VESm and DCm for the screening of a myopic LASIK yield, respectively, sensitivity rates of 92.7% and 95.1% and specificity rates of 94.9% and 96.5%. The features VESh and DCh for the screening of a hyperopic LASIK gave sensitivity rates of 93.1% for both and specificity rates of 94.8% and 97.1%. The performance of those features was superior to clinical assessment using topography color maps. CONCLUSIONS: Criteria based on Orbscan II corneal topography are proposed for the detection of previous hyperopic and myopic LASIK performed with a Technolas excimer laser (version 217C or 217Z).

Adolescent↗

Three-dimensional trajectory assessment of an IVUS transducer from single-plane cineangiograms: a phantom study.

The recovery of the three-dimensional (3-D) path of the transducer used during an intravascular ultrasound (IVUS) examination is of primary importance to assess the exact 3-D shape of the vessel under study. Traditionally, the reconstruction is done by simply stacking the images during the pullback, or more recently using biplane angiography to recover the vessel curvature. In this paper, we explain, how single-plane angiography can be used with two projection models, to perform this task. Two types of projection geometry are analyzed: weak-perspective and full-perspective. In weak-perspective projection geometry, the catheter path can be reconstructed without prior transducer depth information. With full-perspective projection geometry, precise depth location of reference points are needed in order to minimize the error of the recovered transducer angle of incidence. The transducer angulation reconstruction is based on the foreshortening effect as seen from the X-ray images. By comparing the measured to the true transducer length, we are able to get its incidence angle. The transducer trajectory is reconstructed by stitching together the different estimated angulations obtained from each image in a cineangiogram sequence. The method is described and validated on two helical vessel phantoms, giving on average a reconstructed path that is less than 2 mm distant from the true path when using full-perspective projection.

Catheterization↗

Detection of diffuse abnormal perfusion in SPECT using a normal brain atlas.

Visual assessment, with significant inter- or intraobserver variability, is still the norm for the evaluation of Single Photon Emission Computerized Tomography (SPECT) cerebral perfusion studies. We present in this paper an automated method for screening SPECT studies to detect diffuse disseminated abnormalities based on a computerized atlas of normal regional cerebral blood flow (rCBF). To generate the atlas, a set of normal brain SPECT studies are registered together. The atlas contains the intensity mean, the nonlinear displacement mean, and the variance of the activity pattern. A patient is then evaluated by registering his or her SPECT volume to the atlas and computing the nonlinear 3-D displacement of each voxel needed for the best shape fit to it. A voxel is counted as "abnormal" if the intensity difference between the atlas and the registered patient (or if the 3-D motion necessary to move the voxel to its registered position) is superior to 3 SD of normal mean. The number of abnormal voxels is used to classify studies. We validated this approach on 24 SPECT perfusion studies selected visually for having clear diffuse anomalies and 21 normal studies. A Markovian segmentation algorithm is also used to identify the white and gray matters for regional analysis. Based on the number of abnormal voxels, two supervised classifiers were tested: (1) minimum distance-to-mean and (2) Bayesian. The analysis of the intensity and displacement "abnormal" voxels allow one to achieve an 80% correct classification rate for the whole brain and a 93% rate if we consider only voxels in the segmented gray matter region.

Algorithms↗

Topography-based screening for previous laser in situ keratomileusis to correct myopia.

PURPOSE: To demonstrate the feasibility of developing a screening tool based on corneal topography to detect previous myopic laser in situ keratomileusis (LASIK). SETTING: Clinical data from a private clinic analyzed in a university setting. METHODS: Two hundred thirty-three topographies were randomly selected so 1 topography per patient was used: 150 from unoperated corneas and 83 from corneas that had LASIK to correct myopia. The mean surgical correction was -4.40 diopters (D) +/- 2.53 (SD) (range -11.00 to -0.38 D). All topographies were performed using an Orbscan II unit (Bausch & Lomb Surgical). The LASIK procedures were performed using a Technolas 217C excimer laser and a Hansatome microkeratome (Bausch & Lomb Surgical). The algorithms used the mean value of the directional derivative (DT) of the anterior tangential curvature of the cornea in the 2.2 mm radius central disk and the mean value of the anterior elevation (E) with respect to the best-fit sphere in the 0.5 mm radius central disk. Topographies in the testing set (n = 119) were classified as operated if E < 0 (E algorithm) or DT > 0 (DT algorithm) or as unoperated. RESULTS: The E algorithm yielded 0% false positives and 16.7% false negatives and the DT algorithm, 6.5% and 7.1%, respectively. For myopia greater than -1.12 D, the DT algorithm provided a 0% false negative rate. The performance of E and DT algorithms, used in combination, was superior to clinical assessment. CONCLUSION: Criteria based on Orbscan II corneal topography are proposed for the detection of previous myopic LASIK performed with a Technolas 217C excimer laser.

Adolescent↗