PubMed Health⌕ Search

Biomedical subjects

Jean Yves Bansard

Publications and source records attributed to Jean Yves Bansard.

2 recordsLinked to original sources

Impedance cardiographic waveforms in children: Involvement in left ventricular ejection time determination during anesthesia.

OBJECTIVE: The physiologic basis of the impedance cardiographic (ICG) signal is still a matter of debate. An accurate determination of left ventricular ejection time (LVET) is needed to calculate stroke volume. In children, several shapes of the ICG signal are observed during anesthesia or in critical care. The aim of this study was to determine the relationship between the shape of the ICG signal and various morphologic and hemodynamic determinants obtained with Doppler echocardiography to highlight the effect of the various shapes in the accuracy of LVET determination. DESIGN: Prospective study. SETTING: Pediatric surgery in a university hospital. PATIENTS: 103 children, ASA physical status I or II. INTERVENTIONS: General anesthesia for elective surgery. Measurements: Electrocardiography, ICG, and Doppler echocardiography were recorded simultaneously. Classic hemodynamic variables, such as heart rate, LVET, stroke volume, or systemic vascular resistance, were measured or calculated. A mathematical model of the ICG signal was used to determine the shape of the ICG signal and its potential relationship to various morphologic and hemodynamic determinants. The ICG signal shape was then modeled with the normalized amplitudes (NHA) and phase (NHP) of the three harmonics of the fundamental signal. Analysis was performed with a multiple correspondence analysis. RESULTS: ICG method LVET did not significantly correlate with LVET determined with Doppler or with heart rate. NHA and NHP of the ICG signal were not significantly related to LVET determined with Doppler or to stroke volume. NHA were linked to heart rate and the relative length of the cardiac diastolic period. CONCLUSION: The absence of relationship between LVET determined with Doppler and the main variables defining the shape of the ICG signal highlight the relative limit of stroke volume determination with ICG method. The involvement of the arterial compliance in the ICG signal shape can be discussed in regard to the links between NHA and both heart rate and the relative length of the cardiac diastolic period, respectively.

Journal Article↗

Comparison of heart rate response to an epinephrine test dose and painful stimulus in children during sevoflurane anesthesia: heart rate variability and beat-to-beat analysis.

BACKGROUND AND OBJECTIVES: During regional anesthesia, various stimuli leading to an adrenergic response can occur. However, simulation of an epidural test dose by using intravenous administration of epinephrine (EPI) has always been compared with an intravenous saline infusion as the control. The aim of this study was to evaluate the possibility of distinguishing in children the effect on HR by an intravascular epinephrine infusion and a painful stimulus, using heart rate variability (HRV) and beat-to-beat analysis of HR. METHODS: Thirty American Society of Anesthesiologists physical status P I children who required elective surgery were studied. At 1 minimum alveolar concentration (MAC) of sevoflurane, electrocardiogram was recorded continuously. Systolic blood pressure (SBP) was measured every minute. Measurements were performed after an intravenous administration of 0.5 microg/kg of epinephrine and during a small skin surgical incision (SI). Time-varying auto-regressive modeling of the interpolated RR sequences was performed for estimating power spectrum (msec(2)). The HF bands were defined by (0.15-0.4 Hz). RESULTS: Median (range) age and weight of all children were 3.5 (1-10) years and 16 (9-30) kg. EPI produced a lower increase in HR than did SI. SBP increased significantly more than did after SI. T-wave amplitude increased significantly after EPI but not after SI. Sixty seconds after the first change in HR, a secondary decrease (in comparison to control value) can be detected with EPI in contrast to SI. HF spectral power increased significantly after EPI administration but decreased after SI. The sensitivity, specificity, and positive and negative predictive value were respectively for DeltaHR >10 beats per minuteof 56%, 26%, 43%, and 38%; for DeltaSBP >15 mm Hg of 60%, 86%, 81%, and 67%; and for DeltaT-wave amplitude >25% of 86%, 73%, 76%, and 84%. Using detection of the secondary decrease of HR, 60 seconds after the first change in HR, sensitivity, specificity, and positive and a negative predictive value were respectively 96%, 100%, 100%, and 96%. CONCLUSIONS: Detection of the secondary HR decrease, 60 seconds after the first change in HR, allows us to distinguish the effects of a painful stimulus from those related to the epinephrine test dose at 1 MAC of sevoflurane. This secondary HR decrease induced by epinephrine appears primarily because of a compensatory increase in parasympathetic tone.

Adrenergic Agonists↗