PubMed Health⌕ Search

Biomedical subjects

Jean-Louis Marty

Publications and source records attributed to Jean-Louis Marty.

11 recordsLinked to original sources

Highly sensitive amperometric immunosensors for microcystin detection in algae.

The presence of cyanobacterial toxins in water and algae pose a health hazard for animals and humans, due to their tumour-promoting activity and carcinogen effects. The use of simple, rapid and reliable tools for routine analysis is becoming a necessity. With this purpose, our group has developed two electrochemical immunosensors for the detection of microcystin-LR (MC-LR) based on the affinity between this cyanotoxin and the corresponding monoclonal and polyclonal antibodies. A competitive direct enzyme-linked immunosorbent assays (ELISAs) was designed and, after validation of the approach on microtiter wells, screen-printed graphite electrodes were used as supports. Colorimetry was used to optimise the experimental parameters and to compare the performance of monoclonal and polyclonal antibodies. Afterwards, electrochemical measurements were performed at -200 mV (versus Ag/AgCl) using 5-methyl-phenazinium methyl sulfate (MPMS) as mediator for horseradish peroxidase (HRP), the enzymatic label of the competitor. The IC(50) values were 0.10 and 1.73 microgL(-1) for MAb and PAb, respectively. Whereas Mab provided higher sensitivities, the reproducibility was better when using PAb. The developed amperometric immunosensors were applied to the analysis of cyanobacterial samples from the Tarn River (Midi-Pyrénées, France) and the presence of MC was confirmed by the colorimetric protein phosphatase inhibition (PPI) assay and high performance liquid chromatography (HPLC). The limits of detection attained from the calibration curves and the results obtained for the real samples demonstrate the potential use of the immunosensors as screening tools for routine use in the assessment of water quality and the control of toxins in algae.

Biosensing Techniques↗

Twenty years research in cholinesterase biosensors: from basic research to practical applications.

Over the last decades, cholinesterase (ChE) biosensors have emerged as an ultra sensitive and rapid technique for toxicity analysis in environmental monitoring, food and quality control. These systems have the potential to complement or replace the classical analytical methods by simplifying or eliminating sample preparation protocols and making field testing easier and faster with significant decrease in costs per analysis. Over the years, engineering of more sensitive ChE enzymes, development of more reliable immobilization protocols and progress in the area of microelectronics could allow ChE biosensors to be competitive for field analysis and extend their applications to multianalyte screening, development of small, portable instrumentations for rapid toxicity testing, and detectors in chromatographic systems. In this paper, we will review the research efforts over the last 20 years in fabricating AChE biosensors and the recent trends and challenges encounter once the sensor is used outside research laboratory for in situ real sample applications. The review will discuss the generations of cholinesterase sensors with their advantages and limitations, the existing electrode configurations and fabrication techniques and their applications for toxicity monitoring. We will focus on low-cost electrochemical sensors and the approaches used for enzyme immobilization. Recent works for achieving high sensitivity and selectivity are also discussed.

Biosensing Techniques↗

Strategies to develop malic acid biosensors based on malate quinone oxidoreductase (MQO).

An amperometric biosensor based on malate quinone oxidoreductase (MQO) was developed for monitoring of the malolactic fermentation of wines. Screen-printed electrodes coupled with appropriate mediators were used as transducers for this novel biosensor. MQO was immobilized by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) on the surface of the working electrode. Several electrochemical mediators were studied in order to lower the applied potential and minimise the matrix effects. Among them, 2,6-dichlorophenol indophenol (DPIP) and phenazine methosulfate (PMS) were chosen for further development. The working conditions (mediator concentration, applied potential and pH) were optimised for both DPIP and PMS. Detection limits for both types of biosensors were of 5 microM malic acid. Sensitivities obtained for the linear part of the calibration curve were 0.85 and 1.7 mA/M for the biosensors based on DPIP and PMS, respectively. Interferences due to non-specific oxidations were shown to be negligible when using PMS as mediator.

Biosensing Techniques↗

Towards the protein phosphatase-based biosensor for microcystin detection.

A colorimetric test for the detection of microcystins based on immobilised protein phosphatase (PP) has been developed. A PP2A produced by molecular engineering has been used and its performance has been compared to those of commercial PP2A and PP1. Covalent immobilisation of the enzyme using glutaraldehyde, encapsulation by sol-gel and entrapment with photocrosslinkable poly(vinyl alcohol) bearing styrylpyridinium groups (PVA-SbQ) have been compared, the latter method providing the highest immobilisation yields. Screen-printed carbon electrodes (SPEs), Maxisorp microtiter wells and Ultrabind modified polyethersulfone affinity membranes have been used as immobilisation supports. Whilst the highest immobilisation yields were obtained with microtiter wells, the highest operational and storage stabilities were achieved with carbon SPEs and membranes, respectively. The immobilisation of PP by PVA-SbQ provided a means to preserve the enzymatic activity, which decreased at fast rates when the enzyme was kept in solution. The colorimetric test using p-nitrophenyl phosphate has demonstrated that the immobilised enzyme is able to recognise both microcystin variants (MC-LR and MC-RR), although optimisation work should be performed to achieve appropriate limits of detection. With the purpose to develop an electrochemical biosensor, several phosphorylated substrates have been used. Promising results have been achieved with the commercial enzymes and alpha-naphtyl phosphate, p-aminophenol phosphate and catechol monophosphate as enzyme substrates, guaranteeing the viability of the electrochemical approach.

Biosensing Techniques↗

Comparative investigation between acetylcholinesterase obtained from commercial sources and genetically modified Drosophila melanogaster: application in amperometric biosensors for methamidophos pesticide detection.

Genetically modified acetylcholinesterase (AChE) from Drosophila melanogaster (dm) and from commercial sources, Electric eel (ee), Bovine erythrocites (be) and Human erythrocites (he), were investigated as biological receptors for the detection of methamidophos pesticide based on inhibition studies. Most engineered variant of AChE from dm showed enhanced sensitivity toward methamidophos pesticide. Among 24 dmAChE variants tested, 12 presented a sensitivity comparable to the commercially available eeAChE, but higher than AChEs from be and he. Four were found more sensitive and six others were insensitive to methamidophos insecticide. The D375G,Y370F,Y374A,F376L mutant was the most sensitive, with a ki value of 2.2 X 10(6) mol(-1) L min(-1), three orders of magnitude higher than eeAChE (1.1 X 10(3) mol(-1) L min(-1)). The sensor constructed with genetically modified enzyme showed better characteristics with respect to detection limit and sensitivity compared with those using commercial eeAChE. Differential pulse polarography and chronoamperometry were used as electrochemical techniques to characterize the AChE biosensors. The lower detection limit of 1 ppb was obtained with D375G,Y370F,Y374A,F376L mutant of dmAChE, compared to 90 ppb for the commercial eeAChE. This study may stimulate scientists to develop more sensitive and selective procedures for organophosphorus insecticides detection by using engineered variant of dmAChE.

Acetylcholinesterase↗

Versatile method of cholinesterase immobilisation via affinity bonds using Concanavalin A applied to the construction of a screen-printed biosensor.

Development of new and more reliable methods to immobilise biomolecules has emerged rapidly due to a continuous need for more stable, sensitive and reliable biosensors. This paper reports a new method of acetylcholine-esterase (AChE) immobilisation based on the high affinity interaction between the glycoproteic enzyme and Concanavalin A (Con A). In order to establish the nature of the link formed between the glycoenzyme, lectin and support, three different configurations are presented. The optimum immobilisation procedure was further used for biosensor manufacturing. The non-specific adsorption is around 3% and the chemical cross-linking of the proteins is avoided. The optimised method allows loading of the working electrode surface with different amounts of enzyme ranging from 0.3 to 3.3 mIU with a good operational stability. The sensor showed a linear response range to acetylthiocholine substrate between 10 and 110 micromol l(-1) with a sensitivity of 3.6 mA l mol(-1). The applicability of the method to the detection of organophosphorus insecticides resulted in a detection limit of 10(-8) mol l(-1) for chlorpyriphos.

Biosensing Techniques↗

Development of an EnFET for the detection of organophosphorous and carbamate insecticides.

A biosensor for the detection of insecticides based on an ion-sensitive field-effect transistor (ISFET) was developed. The resulting device combines the simplicity of potentiometric sensors and the use of associated electronic systems as powerful tools for the acquisition and the processing of data. The enzyme acetylcholinesterase (AChE) was entrapped in a membrane placed on the gate of the ISFET forming an enzyme field-effect transistor (EnFET). The biosensor is applied to the determination of pesticides in spiked real samples. Organophosphorous and carbamate insecticides were measured with a detection limit of 10(-8) mol L(-1). The measurement is based on the production of hydrogen ions due to the hydrolysis of acetylthiocholine by the enzyme. The resulting local pH change is picked up by the underlying pH-sensitive ISFET and transduced as potential variations. The preparation of the membrane is simple and reproducible. The analysis in spiked real samples was performed in tap water and showed detection limits comparable to those obtained by other researchers.

Acetylcholinesterase↗

Detection of organophosphorus insecticides with immobilized acetylcholinesterase - comparative study of two enzyme sensors.

Two-enzyme systems based on acetylcholinesterase (AChE) - a mono-enzyme system based on AChE, with p-aminophenyl acetate as substrate, and a bi-enzyme system based on AChE and tyrosinase, with phenyl acetate as substrate - have been studied for detection of organophosphate insecticides. The analytical performance and detection limits for determination of the pesticides were compared for the two AChE configurations. The enzyme loading, pH, and applied potential of the bi-enzyme system were optimised. When phenyl acetate was used as substrate for AChE activity the phenol generated by enzymatic hydrolysis was determined with a second enzyme, tyrosinase. Amperometric measurements were performed at 100 mV and -150 mV relative to the Ag/AgCl reference electrode for the mono-enzyme and bi-enzyme systems. Screen-printed sensors were used to detect the organophosphorus pesticides paraoxon and chlorpyrifos ethyl oxon; the detection limits achieved with phenyl acetate as substrate were 5.2x10(-3) mg L(-1) and 0.56x10(-3) mg L(-1), respectively.

Acetylcholinesterase↗

Biosensors designed for environmental and food quality control based on screen-printed graphite electrodes with different configurations.

Graphite electrodes fabricated by screen-printing have been used as amperometric detectors in biosensors based on NAD(+)-dependent dehydrogenases, tyrosinase, or genetically modified acetylcholinesterases. The mono-enzyme sensors have been optimized as disposable or reusable devices for detection of a variety of substrates important in the food industry ( D-lactic acid, L-lactic acid, acetaldehyde) or in environmental pollution control (phenols and dithiocarbamate, carbamate and organophosphorus pesticides). The sensors were prepared in four configurations differing in enzyme confinement, enzyme immobilization and location of the immobilization agent in the biosensor assembly. Tests on real samples have been performed with the biosensors; D-lactic acid and acetaldehyde have been detected in wine and phenols in air.

Acetaldehyde↗

Detection of anatoxin-a(s) in environmental samples of cyanobacteria by using a biosensor with engineered acetylcholinesterases.

Bioassays are little used to detect individual toxins in the environment because, compared to analytical methods, these assays are still limited by several problems, such as the sensitivity and specificity of detection. We tentatively solved these two drawbacks for detection of anatoxin-a(s) by engineering an acetylcholinesterase to increase its sensitivity and by using a combination of mutants to obtain increased analyte specificity. Anatoxin-a(s), a neurotoxin produced by some freshwater cyanobacteria, was detected by measuring the inhibition of acetylcholinesterase activity. By using mutated enzyme, the sensitivity of detection was brought to below the nanomole-per-liter level. However, anatoxin-a(s) is an organophosphorous compound, as are several synthetic molecules which are widely used as insecticides. The mode of action of these compounds is via inhibition of acetylcholinesterase, which makes the biotest nonspecific. The use of a four-mutant set of acetylcholinesterase variants, two mutants that are sensitive to anatoxin-a(s) and two mutants that are sensitive to the insecticides, allows specific detection of the cyanobacterial neurotoxin.

Animals↗

Interference-free biosensor based on screen-printing technology and sol-gel immobilization for determination of acetaldehyde in wine.

A monoenzymatic amperometric biosensor was developed for the detection of acetaldehyde. The sensor is based on the association of screen-printed carbon electrodes and aldehyde dehydrogenase immobilized by a sol-gel entrapment method. Modification of screen-printed carbon electrodes with Reinecke salt of Meldola's Blue (MBRS) resulted in highly sensitive and interference-free nicotinamide-adenine dinucleotide (NADH) detectors. Based on MBRS-mediated oxidation of NADH at -150 mV versus pseudo Ag/AgCl, acetaldehyde was determined in the range 10-260 microM, compatible with wine quality monitoring. The method of immobilization based on sol-gel entrapment was optimized to obtain the best compromise between sensitivity and operational stability. The sensor response was stable for 40 consecutive assays with methyltrimethoxysilane used as alkoxide precursor, thus allowing a possible calibration of the sensor before each measurement. The biosensors were used to analyze French wines. The method was validated with a commercially available enzymatic kit based on a standard spectrophotometric method.

Acetaldehyde↗