PubMed Health⌕ Search

Biomedical subjects

Jean-Louis Rocca

Publications and source records attributed to Jean-Louis Rocca.

9 recordsLinked to original sources

Effect of temperature on the retention of ionizable compounds in reversed-phase liquid chromatography: application to method development.

The analysis of pharmaceutical compounds is often a difficult challenge which requires mathematical tools to improve the quality of the separation method. This work is an attempt to rationalize the anomalous variation of the logarithm of the retention factor with temperature in case of ionizable compounds. The effect of temperature on ionizable compounds was studied within a large range of temperature, ranging from 30 to 130 degrees C. The determination of the so-called chromatographic pKa and the study of its variation with temperature allow to explain why the forms of the van't Hoff curves are so different depending on the type of solute, the type of buffer and the type of the mobile phase. A retention model along with a computation procedure is proposed to optimize both temperature and mobile phase composition and to provide good and robust conditions as shown by illustrative examples.

Algorithms↗

Synthesis of zirconia monoliths for chromatographic separations.

The aim of this work is to join the advantages of two different kinds of stationary phases: monolithic columns and zirconia-based supports. On the one hand, silica monolithic columns allow a higher efficiency with a lower back-pressure than traditional packed columns. On the other hand, chromatographic stationary phases based on zirconia have a higher thermal and chemical stability and specific surface properties. Combining these advantages, a zirconia monolith with a macroporous framework could be a real improvement in separation sciences. Two main strategies can be used in order to obtain a zirconia surface on a monolithic skeleton: coating or direct synthesis. The coverage by a zirconia layer of the surface of a silica-based monolith can be performed using the chemical properties of the silanol surface groups. We realized this coverage using zirconium alkoxide and we further grafted n-dodecyl groups using phosphate derivatives. Any loss of efficiency was observed and fast separations have been achieved. The main advance reported in this paper is related to the preparation of zirconia monoliths by a sol-gel process starting from zirconium alkoxide. The synthesis parameters (hydrolysis ratio, porogen type, precursor concentration, drying step, etc.) were defined in order to produce a macroporous zirconia monoliths usable in separation techniques. We produced various homogeneous structures: zirconia rod 2 cm long with a diameter of 2.3 mm, and zirconia monolith inside fused silica capillaries with a 75 microm I.D. These monoliths have a skeleton size of 2 microm and have an average through pore size of 6 microm. Several separations have been reported.

Amines↗

Hydrodynamic flow and electroosmotic flow in zirconia-packed capillaries.

Fused-silica capillaries were packed with Zirchrom-PBD stationary phase for application in CEC, nanoLC and pseudoelectrochromatography (PEC). Acido-basic properties of zirconia can be used to control the EOF even if the zirconia particles were coated by polybutadiene. As for native zirconia, the EOF is pH-dependent and the pI is close to pH 5. The mixed-mode pressure-voltage technique induced a modulation of the mobile-phase velocity as well as an electrophoretic migration of the solutes in order to improve the resolution of the separation. A significant increase of the flow appeared when both hydrodynamic and EOFs were in the same direction. But an important reduction of the electroosmotic velocity was observed when the hydrodynamic flow and EOF were opposed in Zirchrom-PBD columns. This behaviour has been observed at high or low pH on several columns. Separations of neutral and charged compounds have been performed with these columns in PEC mode.

Chromatography↗

Electrochromatographic behavior of silica monolithic capillaries of different skeleton sizes synthesized with a simplified and shortened sol-gel procedure.

Silica monolithic capillaries (SMCs) were synthesized by a sol-gel process. First, a simplification of the synthesis was proposed by replacing the calcination and the drying steps which can have tremendous effects on chromatographic and physical properties, by a single water or methanol 2 h washing step. The efficiency of such a washing step was demonstrated and the comparison of the chromatographic and electrochromatographic properties between calcined and washed SMCs has shown that such a modification did not impair retention, efficiency, and stability of the monolith. This simplified procedure was carried out to synthesize SMCs with two different skeleton sizes. These capillaries were evaluated in electrochromatography and present high efficiencies (H = 5 microm) at least equal to the best ones reported in the literature. Furthermore, the influence of the skeleton size on the EOF of the second kind (EOF-2) was investigated with unmodified SMCs used under various experimental conditions including electrical field strength and buffer concentration. The ionic strength of the mobile phase and the applied electrical field that enable this EOF-2 were related to the size of the skeleton which was tuned by the synthesis conditions.

Capillary Electrochromatography↗

Spherical ordered mesoporous silicas and silica monoliths as stationary phases for liquid chromatography.

Ordered mesoporous silicas such as micelle-templated silicas (MTS) feature unique textural properties in addition to their high surface area (approximately 1000 m2/g): narrow mesopore size distributions and controlled pore connectivity. These characteristics are highly relevant to chromatographic applications for resistance to mass transfer, which has never been studied in chromatography because of the absence of model materials such as MTS. Their synthesis is based on unique self-assembly processes between surfactants and silica. In order to take advantage of the perfectly adjustable texture of MTS in chromatographic applications, their particle morphology has to be tailored at the micrometer scale. We developed a synthesis strategy to control the particle morphology of MTS using the concept of pseudomorphic transformation. Pseudomorphism was recognized in the mineral world to gain a mineral that presents a morphology not related to its crystallographic symmetry group. Pseudomorphic transformations have been applied to amorphous spherical silica particles usually used in chromatography as stationary phases to produce MTS with the same morphology, using alkaline solution to dissolve progressively and locally silica and reprecipitate it around surfactant micelles into ordered MTS structures. Spherical beads of MTS with hexagonal and cubic symmetries have been synthesized and successfully used in HPLC in fast separation processes. MTS with a highly connected structure (cubic symmetry), uniform pores with a diameter larger than 6 nm in the form of particles of 5 microm could compete with monolithic silica columns. Monolithic columns are receiving strong interest and represent a milestone in the area of fast separation. Their synthesis is a sol-gel process based on phase separation between silica and water, which is assisted by the presence of polymers. The control of the synthesis of monolithic silica has been systematically explored. Because of unresolved yet cladding problems to evaluate the resulting macromonoliths in HPLC, micromonoliths were synthesized into fused-silica capillaries and evaluated by nano-LC and CEC. Only CEC allows to gain high column efficiencies in fast separation processes. Capillary silica monolithic columns represent attractive alternatives for miniaturization processes (lab-on-a chip) using CEC.

Journal Article↗

A study of interlaboratory influence on column evaluation.

A liquid chromatography method for the characterization of base deactivated columns was investigated in a collaborative study involving six laboratories. This work was carried out on two chromatographic supports (Xterra RP 18 and Symmetry Shield). Different cooling systems, namely water bath and air oven, were tested and it was shown that column thermoregulation did not significantly influence chromatographic data. In order to control the mobile phase composition, the latter was prepared by weight rather than volume. Thanks to the injection of a set of selected neutral compounds, extra-column effects were evaluated in each of the participating laboratories. The results showed that chromatographic supports tested in different laboratories and following the same test protocol could be effectively compared.

Chromatography, High Pressure Liquid↗

Development of acrylate-based monolithic stationary phases for electrochromatographic separations.

Organic monolithic stationary phases were synthesized in fused-silica capillaries. They were prepared by in situ polymerization under UV irradiation of various alkyl acrylates, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid in a ternary porogenic solvent. The resulting stationary phases were tested in CEC. The influence of UV irradiation energy on the resulting separative performances of the monoliths was studied. It was thus demonstrated that the use of hexyl acrylate rather than butyl acrylate and lauryl methacrylate gives highly efficient monoliths (more than 300 000 plates per meter) with optimized EOF. It was also confirmed that the mobile phase ionic strength may affect significantly the separation efficiency. The influence of the nature of the mobile phase organic modifier (ACN or methanol) on EOF, retention, efficiency, and selectivity was studied and differences were observed. Finally, the performances of monolithic stationary phases developed and optimized for CEC separations were evaluated in nanoLC.

Acrylates↗

Some advantages of high temperature for the separation of pharmaceutical compounds with mass spectrometry detection.

The beneficial effects of high temperature on separation and detection of basic compounds, the detection being performed by MS via ESI, are investigated. The influence of various parameters on both separation and detection performances is studied. These parameters include the mobile phase pH, the temperature, and the type of stationary phase. Experiments are performed under gradient elution conditions. The results obtained with four different supports, silica-, zirconia-, carbon-, and polymer-based columns, are compared by means of different criteria including the elution composition, the peak asymmetry, and the S/N. High temperature liquid chromatography at high pH with volatile buffers suitable for MS detection was shown to be an interesting choice for solutes with basic sites.

Chromatography, Liquid↗

Development and in situ synthesis of monolithic stationary phases for electrochromatographic separations.

Organic monolithic stationary phases have been synthesized in UV-transparent fused-silica capillaries, which have been used as test format of microfabricated device channels. The columns have been prepared by in situ polymerization of butyl acrylate, lauryl acrylate, 1,3-butanediol diacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) in a ternary porogenic solvent. The resulting stationary phases have been tested in capillary electrochromatography and exhibited reversed-phase chromatography behavior toward neutral solutes. Van Deemter plots of phenylureas and polycyclic aromatic hydrocarbons, selected as model analytes, have been determined to study the influence of various polymerization and separation parameters on properties of the monoliths. The amount of AMPS and the nature of monomers in the polymerization solution have been thus adjusted. It has been observed that the ionic strength of the mobile phase may affect significantly the efficiency of the separation. The effect of the percentage of acetonitrile in the mobile phase on efficiency and permeability of the organic monoliths has also been investigated. Efficiencies greater than 300,000 plates/m have been obtained with the test compounds. Stability and reproducibility have been extensively studied.

Chromatography, Micellar Electrokinetic Capillary↗