PubMed Health⌕ Search

Biomedical subjects

Jeanne M Decara

Publications and source records attributed to Jeanne M Decara.

7 recordsLinked to original sources

Harmonic imaging for endocardial visualization and myocardial contrast echocardiography during transesophageal echocardiography.

BACKGROUND: Although harmonic imaging (HI) improves endocardial visualization and is necessary for myocardial perfusion imaging, it has yet to be implemented in transesophageal echocardiography. Our goal was to determine whether HI implemented in a prototype transesophageal echocardiography probe improved endocardial visualization and allowed perfusion imaging. METHODS: In 23 patients, fundamental and harmonic images were obtained in the transgastric short-axis (TSAX) and midesophageal 4-chamber views, and reviewed for endocardial visualization by 3 readers blinded to imaging mode. In 14 additional patients, perfusion imaging was performed in the TSAX view during contrast infusion. RESULTS: HI improved overall endocardial visualization, most noticeably in the anterior and lateral segments (P <.004) in the TSAX view, and in the lateral segments (P <.01) in the midesophageal 4-chamber view. The salvage rate was 8.3% in the TSAX view and 12.6% in the midesophageal 4-chamber view. Myocardial perfusion was consistently confirmed in the inferior (86%), posterior (100%), and lateral (79%) segments, but rarely in the septal (21%), anteroseptal (0%), and anterior (14%) segments. CONCLUSION: Use of HI with transesophageal echocardiography improves endorcardial visualization and allows partial assessment of myocardial perfusion.

Coronary Circulation↗

Age dependency of the Tei index of myocardial performance.

Despite its clinical use as a sensitive measure of left ventricular performance, little is known about whether the Tei index is influenced by aging. We determined the Tei index in 141 subjects without cardiovascular disease (age 16-78 years). There were statistically significant variations in ejection time, isovolumic relaxation time, and the Tei index with aging. There was a moderate linear correlation between isovolumic relaxation time and age (r = 0.49, P <.001) and the Tei index and age (r = 0.33, P <.001). This investigation demonstrated that when assessing myocardial performance in patients using this index, age-normalized values should be used.

Adolescent↗

Hand-carried cardiac ultrasound as a tool to screen for important cardiovascular disease in an underserved minority health care clinic.

The disparity in cardiovascular outcomes among racial and social strata may be, in part, because of delayed detection of cardiovascular disease in minority patients. The low cost and portability of hand-carried cardiac ultrasound devices may make screening of underserved patients for cardiac disease feasible. A general internist evaluated 153 patients at a clinic serving an underserved population with a hand-carried cardiac ultrasound device. A total of 27 cases of significant valvular heart disease or ventricular dysfunction were detected in 19 patients (12.4%). Detection of a major cardiac abnormality could not be predicted by cardiac risk factors, age, or chief symptom, whereas patients presenting for new or acute clinic visits were more likely to have an abnormality. The low cost and portability of hand-carried cardiac ultrasound devices may make them important tools for the early detection of cardiovascular disease in minority and underserved populations and, thereby, help to reduce disparities in cardiovascular outcomes.

Cardiovascular Diseases↗

Automated quantitative assessment of wall motion in patients with poor acoustic windows.

BACKGROUND: No technique exists for objective evaluation of left ventricular wall motion in contrast-enhanced images. We tested a new technique for quantification of regional fractional area change using contrast-enhanced power modulation imaging with color kinesis. METHODS: The feasibility of this technique for detecting acute ischemia was first tested in 11 pigs. Next, the accuracy for detecting resting wall-motion abnormalities was determined in 52 patients requiring contrast and compared with conventional interpretation of 2-dimensional images by inexperienced readers. Expert interpretation of 2-dimensional images served as the gold standard. RESULTS: In pigs, coronary occlusion resulted in reversible hypokinesis and reduced regional fractional area change. In patients with poor acoustic windows, this technique's accuracy for quantitative detection of resting wall-motion abnormalities was 86% compared with 81% for conventional interpretation by inexperienced readers (P <.01). CONCLUSIONS: Regional wall motion can be accurately assessed using color-encoded power modulation imaging for patients requiring contrast. This technique may prove a useful diagnostic aid to echocardiographers of varying levels of experience.

Animals↗

Biplane stress echocardiography using a prototype matrix-array transducer.

BACKGROUND: Rapid image acquisition after cessation of exercise is essential for accurate stress echocardiography. Recently, a prototype matrix-array transducer has been developed that allows simultaneous acquisition of 2 imaging planes (biplane [BP] imaging). METHODS: In all, 19 healthy volunteers underwent 2 separate stress echocardiographic studies. Images were acquired in traditional 2-dimensional or BP format pre-exercise and postexercise. RESULTS: Total image acquisition time for 2-dimensional stress echocardiography was 38 +/- 8 seconds versus 29 +/- 8 seconds for BP imaging (P <.05). Heart rates were acquired closer to age-predicted maximum with BP imaging in the apical 3- and 2-chamber and parasternal long- and short-axis views (82%, 75%, 70%, 70% for BP vs 76%, 72%, 68%, 66% for 2-dimensional, respectively). CONCLUSION: BP imaging using a recently developed matrix-array probe allows more rapid imaging postexercise, resulting in acquisition of poststress images at higher heart rates without compromising image quality.

Acoustics↗

Accuracy of mitral valve area measurements using transthoracic rapid freehand 3-dimensional scanning: comparison with noninvasive and invasive methods.

OBJECTIVE: The feasibility and accuracy of direct transthoracic 3-dimensional (3D) mitral valve area (MVA) measurements obtained using freehand scanning was investigated in patients with mitral stenosis. METHODS: A total of 30 patients (26 women, 4 men; aged 55 +/- 13 years) underwent a 2-dimensional (2D) and Doppler study 1 hour before percutaneous balloon mitral valvuloplasty. Transthoracic freehand data were acquired using a magnetic receiver attached to a broadband transducer, gated to electrocardiography and respiration. Volumetric MVA measurements from the left ventricle and left atrium were obtained and compared with MVA measurements derived from 2D planimetry, pressure half-time, and proximal isovelocity surface area. Invasive Gorlin MVA measurements were the gold standard for comparison. RESULTS: In all, 29 patients (97%) had 3D data allowing MVA measurements. Direct 3D measurements from the left ventricle had the least bias (0.06 +/- 0.19 cm(2)) and tightest limits of agreement (-0.44 to 0.32) compared with left atrium measurements (0.17 +/- 0.25 cm(2) and -0.67 to 0.33, respectively). The proximal isovelocity surface area method (bias: 0.09 +/- 0.34 cm(2)) was the most accurate of all 2D methods followed by pressure half-time (0.17 +/- 0.36 cm(2)) and planimetry (0.21 +/- 0.29 cm(2)). CONCLUSION: Direct 3D MVA measurements from the left ventricle using transthoracic freehand scanning are more accurate than traditional 2D methods.

Adult↗

Simultaneous real-time echocardiographic imaging of myocardial perfusion and regional function using color-encoded, contrast-enhanced power modulation.

We hypothesized that color-encoded, contrast-enhanced, power modulation imaging could allow simultaneous quantification of myocardial perfusion and regional left ventricular function. We studied 12 anesthetized, closed-chest pigs at baseline, during acute ischemia, and during reperfusion, and 8 patients after acute myocardial infarction. Color kinesis was used to color encode endocardial motion during real-time contrast perfusion imaging with high-energy ultrasound pulses. Wall motion was assessed by calculating regional fractional area changes. Translation-free perfusion analysis was performed in automatically identified myocardial regions of interest. Steady-state intensity and postimpulse rate of contrast replenishment were calculated. In all animals, ischemia caused reversible changes in the images and the perfusion- and function-calculated indices. A significant decrease in pixel intensity (14%) and contrast replenishment rate (66%) in left anterior descending coronary artery segments, in agreement with fluorescent microspheres measurements, coincided with a decrease in fractional area change (34%). For patients, respective perfusion and function indices were 61%, 51%, and 58% lower in segments where perfusion defects, regional wall-motion abnormalities, or both were noted in gray scale images. Color-encoded, contrast-enhanced power modulation allows simultaneous real-time imaging and quantitative analysis of myocardial perfusion and regional left ventricular function.

Animals↗