Clinical implementation of adaptive helical tomotherapy: a unique approach to image-guided intensity modulated radiotherapy.

Image-guided IMRT is a revolutionary concept whose clinical implementation is rapidly evolving. Methods of executing beam intensity modulation have included individually designed compensators, static multi-leaf collimators (MLC), dynamic MLC, and sequential (serial) tomotherapy. We have developed helical tomotherapy as an innovative solution to overcome some of the limitations of other IMRT systems. The unique physical design of helical tomotherapy allows the realization of the concepts of adaptive radiotherapy and conformal avoidance. In principle, these advances should improve normal tissue sparing and permit dose reconstruction and verification, thereby allowing significant biologically effective dose escalation. Recent radiobiological findings can be translated into altered fractionation schemes that aim to improve the local control and long-term survival. This strategy is being tested at the University of Wisconsin using helical tomotherapy with its highly precise delivery and verification system along with meticulous and practical forms of immobilization. Innovative techniques such optical guidance, respiratory gating, and ultrasound assessments are being designed and tailored for helical tomotherapy use. The intrinsic capability of helical tomotherapy for megavoltage CT (MVCT) imaging for IMRT image-guidance is being optimized. The unique features of helical tomotherapy might allow implementation of image-guided IMRT that was previously impossible or impractical. Here we review the technological, physical, and radiobiological rationale for the ongoing and upcoming clinical trials that will use image-guided IMRT in the form of helical tomotherapy; and we describe our plans for testing our hypotheses in a rigorous prospective fashion.

Humans↗

Feasibility study of helical tomotherapy for total body or total marrow irradiation.

Total body radiation (TBI) has been used for many years as a preconditioning agent before bone marrow transplantation. Many side effects still plague its use. We investigated the planning and delivery of total body irradiation (TBI) and selective total marrow irradiation (TMI) and a reduced radiation dose to sensitive structures using image-guided helical tomotherapy. To assess the feasibility of using helical tomotherapy, (A) we studied variations in pitch, field width, and modulation factor on total body and total marrow helical tomotherapy treatments. We varied these parameters to provide a uniform dose along with a treatment times similar to conventional TBI (15-30 min). (B) We also investigated limited (head, chest, and pelvis) megavoltage CT (MVCT) scanning for the dimensional pretreatment setup verification rather than total body MVCT scanning to shorten the overall treatment time per treatment fraction. (C) We placed thermoluminescent detectors (TLDs) inside a Rando phantom to measure the dose at seven anatomical sites, including the lungs. A simulated TBI treatment showed homogeneous dose coverage (+/-10%) to the whole body. Doses to the sensitive organs were reduced by 35%-70% of the target dose. TLD measurements on Rando showed an accurate dose delivery (+/-7%) to the target and critical organs. In the TMI study, the dose was delivered conformally to the bone marrow only. The TBI and TMI treatment delivery time was reduced (by 50%) by increasing the field width from 2.5 to 5.0 cm in the inferior-superior direction. A limited MVCT reduced the target localization time 60% compared to whole body MVCT. MVCT image-guided helical tomotherapy offers a novel method to deliver a precise, homogeneous radiation dose to the whole body target while reducing the dose significantly to all critical organs. A judicious selection of pitch, modulation factor, and field size is required to produce a homogeneous dose distribution along with an acceptable treatment time. In addition, conformal radiation to the bone marrow appears feasible in an external radiation treatment using image-guided helical tomotherapy.

Bone Marrow↗

The utility of megavoltage computed tomography images from a helical tomotherapy system for setup verification purposes.

PURPOSE: To evaluate the utility of relatively low-dose megavoltage computed tomography (MVCT) images from a clinical helical tomotherapy system for setup verification purposes. METHODS AND MATERIALS: Cross-sectional kilovolt computed tomography (kVCT) images were obtained for treatment planning purposes on a diagnostic third-generation CT scanner, followed by MVCT images from a helical tomotherapy system in 8 pet dogs with spontaneously occurring tumors. The kVCT and MVCT images were aligned for setup verification purposes, allowing repositioning before treatment delivery. RESULTS: Tumors are readily visualized on the MVCT images. At a dose of 2-3 cGy, the MVCT images are of sufficient quality for verification of treatment setup, but soft-tissue contrast is inferior to that with conventional kVCT. The MV and kVCT images were successfully aligned. When necessary, patients undergoing helical tomotherapy were repositioned before treatment. CONCLUSIONS: Megavoltage CT image quality is sufficient for tumor identification and three-dimensional setup verification in dogs with spontaneous tumors. The MVCT images can be aligned with the planning kVCT to ensure proper patient registration before treatment. Image alignment was successful in these canine patients, despite no skin markings defining patient positioning between the two scans. MVCT images facilitate setup verification, and their tomographic nature offers improvements over conventional portal imaging.

Animals↗

Radiation characteristics of helical tomotherapy.

Helical tomotherapy is a dedicated intensity modulated radiation therapy (IMRT) system with on-board imaging capability (MVCT) and therefore differs from conventional treatment units. Different design goals resulted in some distinctive radiation field characteristics. The most significant differences in the design are the lack of flattening filter, increased shielding of the collimators, treatment and imaging operation modes and narrow fan beam delivery. Radiation characteristics of the helical tomotherapy system, sensitivity studies of various incident electron beam parameters and radiation safety analyses are presented here. It was determined that the photon beam energy spectrum of helical tomotherapy is similar to that of more conventional radiation treatment units. The two operational modes of the system result in different nominal energies of the incident electron beam with approximately 6 MeV and 3.5 MeV in the treatment and imaging modes, respectively. The off-axis mean energy dependence is much lower than in conventional radiotherapy units with less than 5% variation across the field, which is the consequence of the absent flattening filter. For the same reason the transverse profile exhibits the characteristic conical shape resulting in a 2-fold increase of the beam intensity in the center. The radiation leakage outside the field was found to be negligible at less than 0.05% because of the increased shielding of the collimators. At this level the in-field scattering is a dominant source of the radiation outside the field and thus a narrow field treatment does not result in the increased leakage. The sensitivity studies showed increased sensitivity on the incident electron position because of the narrow fan beam delivery and high sensitivity on the incident electron energy, as common to other treatment systems. All in all, it was determined that helical tomotherapy is a system with some unique radiation characteristics, which have been to a large extent optimized for intensity modulated delivery.

Electrons↗

Helical tomotherapy as a means of delivering accelerated partial breast irradiation.

A novel treatment approach utilizing helical tomotherapy for partial breast irradiation for patients with early-stage breast cancer is described. This technique may serve as an alternative to high dose-rate (HDR) interstitial brachytherapy and standard linac-based approaches. Through helical tomotherapy, highly conformal irradiation of target volumes and avoidance of normal sensitive structures can be achieved. Unlike HDR brachytherapy, it is noninvasive. Unlike other linac-based techniques, it provides image-guided adaptive radiotherapy along with intensity modulation. A treatment planning CT scan was obtained as usual on a post-lumpectomy patient undergoing HDR interstitial breast brachytherapy. The patient underwent catheter placement for HDR treatment and was positioned prone on a specially designed position-supporting mattress during CT. The planning target volume (PTV) was defined as the lumpectomy bed plus a 20 mm margin. The prescription dose was 34 Gy (10 fx of 3.4 Gy) in both the CT based HDR and on the tomotherapy plan. Cumulative dose-volume histograms (DVHs) were generated and analyzed for the target, lung, heart, skin, pectoralis muscle, and chest wall for both HDR brachytherapy and helical tomotherapy. Dosimetric coverage of the target with helical tomotherapy was conformal and homogeneous. "Hot spots" (> or =150% isodose line) were present around implanted dwell positions in brachytherapy plan whereas no isodose lines higher than 109% were present in the helical tomotherapy plan. Similar dose coverage was achieved for lung, pectoralis muscle, heart, chest wall and breast skin with the two methods. We also compared our results to that obtained using conventional linac-based three dimensional (3D) conformal accelerated partial breast irradiation. Dose homogeneity is excellent with 3D conformal irradiation, and lung, heart and chest wall dose is less than for either HDR brachytherapy or helical tomotherapy but skin and pectoral muscle doses were higher than with the other techniques. Our results suggest that helical tomotherapy can serve as an effective means of delivering accelerated partial breast irradiation and may offer superior dose homogeneity compared to HDR brachytherapy.

Brachytherapy↗

Image guidance for precise conformal radiotherapy.

PURPOSE: To review the state of the art in image-guided precision conformal radiotherapy and to describe how helical tomotherapy compares with the image-guided practices being developed for conventional radiotherapy. MATERIALS AND METHODS: Image guidance is beginning to be the fundamental basis for radiotherapy planning, delivery, and verification. Radiotherapy planning requires more precision in the extension and localization of disease. When greater precision is not possible, conformal avoidance methodology may be indicated whereby the margin of disease extension is generous, except where sensitive normal tissues exist. Radiotherapy delivery requires better precision in the definition of treatment volume, on a daily basis if necessary. Helical tomotherapy has been designed to use CT imaging technology to plan, deliver, and verify that the delivery has been carried out as planned. The image-guided processes of helical tomotherapy that enable this goal are described. RESULTS: Examples of the results of helical tomotherapy processes for image-guided intensity-modulated radiotherapy are presented. These processes include megavoltage CT acquisition, automated segmentation of CT images, dose reconstruction using the CT image set, deformable registration of CT images, and reoptimization. CONCLUSIONS: Image-guided precision conformal radiotherapy can be used as a tool to treat the tumor yet spare critical structures. Helical tomotherapy has been designed from the ground up as an integrated image-guided intensity-modulated radiotherapy system and allows new verification processes based on megavoltage CT images to be implemented.

Animals↗

Clinical helical tomotherapy commissioning dosimetry.

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

Equipment Failure Analysis↗