PubMed Health⌕ Search

Biomedical subjects

Jeff Z Chen

Publications and source records attributed to Jeff Z Chen.

4 recordsLinked to original sources

Intensity-modulated arc therapy for treatment of high-risk endometrial malignancies.

PURPOSE: We developed an intensity-modulated arc therapy (IMAT) technique for the treatment of women with high-risk endometrial malignancies. In the context of multimodality therapy, nodal and tumor bed irradiation was delivered while respecting tolerance doses for critical structures. METHODS AND MATERIALS: Five patients were planned and treated with the IMAT technique after hysterectomy. Computed tomographic (CT) scans for treatment planning were acquired with the tumor bed contoured as the clinical target volume (CTV(tumor_bed)) and the iliac and presacral vessels contoured as the gross tumor volume (GTV). In 2 patients the lower para-aortic nodes were included into the GTV. The small bowel, iliac crests, femoral heads, bladder, and rectum were contoured as critical organs. For the nodes, a CTV(nodes) was generated with a 7-10-mm margin around the vessels, and the planning target volume (PTV(nodes)) was generated by a further 5-mm expansion. For the tumor bed, the PTV(tumor_bed) was generated with a margin of 7-10 mm around CTV(tumor_bed). Planning constraints included adequate coverage of the tumor bed (>95% receiving > or =45 Gy) and nodes (> or =95% receiving > or =40 Gy). Arc combinations with different extents were tested, and the final plan was generated based on the balance between complexity (number of arcs), PTV coverage, and critical structure sparing. Conventional and 8-field intensity-modulated radiation therapy (IMRT) plans were generated for each patient for comparison purposes. All patients were treated with IMAT. RESULTS: We found that two anterior intensity-modulated arcs (300 degrees to 30 degrees and 330 degrees to 60 degrees ) adequately treated the PTVs. Furthermore, this IMAT technique allowed sparing of small bowel and the iliac crests (marrow space) to a similar degree as the 8-field IMRT. The 8-field IMRT yielded better dose uniformity than IMAT in the target volumes; however, neither technique was as uniform as the conventional plan. In the 5 patients, IMAT treatment was well tolerated and completed as planned. CONCLUSIONS: We successfully piloted an optimized intensity-modulated arc technique to treat 5 high-risk endometrial cancer patients undergoing multimodality treatment. This allowed a significant reduction in dose to bone marrow and small bowel compared with conventional techniques and was simpler to deliver than multifield IMRT.

Bone Marrow↗

Planning evaluation of radiotherapy for complex lung cancer cases using helical tomotherapy.

Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used around the gross tumour volume (GTV) to generate primary planning target volume (PTV2) and 1 cm margin around elective nodes for secondary planning target volume (PTV1) resulting in PTV1 volumes larger than 1000 cm3 in 13 of the 15 patients. Tomotherapy plans were created using an inverse treatment planning system (TomoTherapy Inc.) based on superposition/convolution dose calculation for a fan beam thickness of 25 mm and a pitch factor between 0.3 and 0.8. For comparison, plans were created using an intensity-modulated radiation therapy (IMRT) approach planned on a commercial treatment planning system (TheraplanPlus, Nucletron). Tomotherapy delivery times for the large target volumes were estimated to be between 4 and 19 min. Using a prescribed dose of 60 Gy to PTV2 and 46 Gy to PTV1, the mean lung dose was 23.8+/-4.6 Gy. A 'dose quality factor' was introduced to correlate the plan outcome with patient specific parameters. A good correlation was found between the quality of the HT plans and the IMRT plans with HT being slightly better in most cases. The overlap between lung and PTV was found to be a good indicator of plan quality for HT. The mean lung dose was found to increase by approximately 0.9 Gy per percent overlap volume. Helical tomotherapy planning resulted in highly conformal dose distributions. It allowed easy achievement of two different dose levels in the target simultaneously. As the overlap between PTV and lung volume is a major predictor of mean lung dose, future work will be directed to control of margins. Work is underway to investigate the possibility of breath-hold techniques for tomotherapy delivery to facilitate this aim.

Carcinoma, Non-Small-Cell Lung↗

Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs.

The objective of this study is to seek an accurate and efficient method to calculate the dose distribution of a photon arc. The algorithms tested include Monte Carlo, pencil beam kernel (PK), and collapsed cone convolution (CCC). For the Monte Carlo dose calculation, EGS4/DOSXYZ was used. The SRCXYZ source code associated with the DOSXYZ was modified so that the gantry angle of a photon beam would be sampled uniformly within the arc range about an isocenter to simulate a photon arc. Specifically, photon beams (6/18 MV, 4 x 4 and 10 x 10 cm2) described by a phase space file generated by BEAM (MCPHS), or by two point sources with different photon energy spectra (MCDIV) were used. These methods were used to calculate three-dimensional (3-D) distributions in a PMMA phantom, a cylindrical water phantom, and a phantom with lung inhomogeneity. A commercial treatment planning system was also used to calculate dose distributions in these phantoms using equivalent tissue air ratio (ETAR), PK and CCC algorithms for inhomogeneity corrections. Dose distributions for a photon arc in these phantoms were measured using a RK ion chamber and radiographic films. For homogeneous phantoms, the measured results agreed well (approximately 2% error) with predictions by the Monte Carlo simulations (MCPHS and MCDIV) and the treatment planning system for the 180 degrees and 360 degrees photon arcs. For the dose distribution in the phantom with lung inhomogeneity with a 90 degrees photon arc, the Monte Carlo calculations agreed with the measurements within 2%, while the treatment planning system using ETAR, PK and CCC underestimated or overestimated the dose inside the lung inhomogeneity from 6% to 12%.

Algorithms↗

Intensity-modulated arc therapy simplified.

PURPOSE: We present a treatment planning strategy for intensity-modulated radiation therapy using gantry arcs with dynamic multileaf collimator, previously termed intensity-modulated arc therapy (IMAT). METHODS AND MATERIALS: The planning strategy is an extension of the photon bar arc and asymmetric arc techniques and is classified into three levels of complexity, with increasing number of gantry arcs. This principle allows us to generalize the analysis of the number of arcs required for intensity modulation for a given treatment site. Using a phantom, we illustrate how the current technique is more flexible than the photon bar arc technique. We then compare plans from our strategy with conventional three-dimensional conformal treatment plans for three sites: prostate (prostate plus seminal vesicles), posterior pharyngeal wall, and chest wall. RESULTS: Our strategy generates superior IMAT treatment plans compared to conventional three-dimensional conformal plans. The IMAT plans spare critical organs well, and the trade-off for simplicity is that the dose uniformity in the target volume may not rival that of true inverse treatment plans. CONCLUSIONS: The analyses presented in this paper give a better understanding of IMAT plans. Our strategy is easier to understand and more efficient in generating plans than inverse planning systems; our plans are also simpler to modify, and quality assurance is more intuitive.

Humans↗