Quantitative apparent diffusion coefficients and T2 relaxation times in characterizing contrast enhancing brain tumors and regions of peritumoral edema.

PURPOSE: To investigate the potential value and relationship of in vivo quantification of apparent diffusion coefficients (ADCs) and T2 relaxation times for characterizing brain tumor cellularity and tumor-related edema. MATERIALS AND METHODS: A total of 26 patients with newly diagnosed gliomas, meningiomas, or metastases underwent diffusion-weighted and six-echo multisection T2-preparation imaging. Regions of interest (ROIs) were drawn on conventional MR images to include tumor (as defined by contrast agent enhancement) and immediate and peripheral edema. Areas of necrosis were excluded. Median values of ADCs and T2 in the ROIs were calculated. RESULTS: ADCs for gliomas were similar to those for meningiomas or metastases in all regions. Tumor T2 values for gliomas (159.5+/-30.6 msec) were significantly higher than those for meningiomas or metastases (125.0+/-31.1 msec; P=0.005). Immediate-edema T2 values for meningiomas or metastases (226.0+/-44.1 msec) were significantly higher than those for gliomas (203.5+/-32.8 msec; P=0.033). Peripheral-edema T2 values for gliomas (219.5+/-41.9 msec) were similar to those for meningiomas or metastases (202.5+/-26.5 msec; P=0.377). Both immediate- and peritumoral-edema ADCs and T2 values were significantly higher than those in tumor for both tumor types. ADCs and T2 values from all regions correlated significantly for gliomas (r=0.95; P<0.0001) and for meningiomas or metastases (r=0.81; P<0.0001). CONCLUSION: The higher immediate-edema T2 values for nonglial tumors than for gliomas suggest tumor-related edema (vasogenic vs. infiltrated) can be further characterized by using T2 values. There were significant correlations between ADC and T2 values.

Adult↗

Real-time magnetic resonance with physiologic monitoring for improved scan localization.

Imaging of the coronary arteries at diagnostic resolutions is made difficult due to cardiac and respiratory motion during data acquisition. Cardiac gating and respiratory gating or breath holding are effective ways to reduce the effects of motion. The optimal cardiac and respiratory timings vary widely across individuals. This work presents a real-time magnetic resonance imaging approach with physiologic monitoring that can be used to predict the optimal timings on a subject-by-subject basis during a brief real-time prescan. The feasibility of this approach at determining the optimal cardiac trigger delay and respiratory phase is demonstrated.

Adult↗

Variable-density adaptive imaging for high-resolution coronary artery MRI.

Variable-density (VD) spiral k-space acquisitions are used to acquire high-resolution (0.78 mm), motion-compensated images of the coronary arteries. Unlike conventional methods, information for motion compensation is obtained directly from the coronary anatomy itself. Specifically, periods of minimal coronary distortion are identified by applying the correlation coefficient template matching algorithm to real-time images generated from the inner, high-density portions of the VD spirals. Combining the data associated with these images together, high-resolution, motion-compensated coronary images are generated. Because coronary motion is visualized directly, the need for cardiac-triggering, breath-holding, and navigator echoes is eliminated. The motion compensation capability of the technique is determined by the inner-spiral spatial and temporal resolution. Results indicate that the best performance is achieved using inner-spiral images with high spatial resolution (1.6-2.9 mm), even though temporal resolution (four to six independent frames per second) suffers as a result. Image quality within the template region in healthy volunteers was found to be comparable to that achieved with cardiac-triggered breath-hold scans, although extended acquisition times of around 5 min were needed to overcome reduced SNR efficiency.

Algorithms↗