PubMed Health⌕ Search

Biomedical subjects

Jeffrey H Maki

Publications and source records attributed to Jeffrey H Maki.

13 recordsLinked to original sources

3D contrast-enhanced MR angiography.

Safe, fast, accurate contrast arteriography can be obtained utilizing gadolinium (Gd) and 3D MR data acquisition for diagnosing vascular diseases. Optimizing contrast enhanced MRA (CE MRA), however, requires understanding the complex interplay between Gd injection timing, the Fourier mapping of 3D MR data acquisition and a multitude of parameters determining resolution, anatomic coverage, and sensitivity to motion artifacts. It is critical to time the bolus peak to coincide with central k-space data acquisition, which dominates image contrast. Oversampling the center of k-space allows reconstruction of multiple 3D acquisitions in rapid succession to time-resolve the passage of the contrast bolus. Parallel imaging increases resolution, shortens scan time and compresses the center of k-space into a shorter period of time, thereby minimizing motion and timing artifacts. Absence of ionizing radiation allows MRA to be repeated and combined with additional sequences to more fully characterize anatomy, flow, and physiology. Utilizing stepping table technology and thigh compression, whole body MRA is possible with a single contrast injection. As MR technology continues to advance, CE MRA becomes better and simpler to perform, increasing its efficacy in the diagnosis and management of vascular diseases.

Artifacts↗

Utilizing SENSE to reduce scan duration in high-resolution contrast-enhanced renal MR angiography.

PURPOSE: To evaluate the use of sensitivity encoding (SENSE) to reduce scan time and decrease detrimental artifacts arising from motion and bolus profile effects during contrast-enhanced MR angiography (CE-MRA) of the renal arteries (RAs). MATERIALS AND METHODS: A direct comparison of conventional and SENSE (acceleration factor 2) CE-MRA protocols was performed on 20 patients. Each patient underwent both scans. Both protocols achieved the same resolution, but the SENSE protocol was 50% faster and utilized a faster injection than the conventional scan. Three radiologists graded the images for image quality, artifact levels, and reader confidence. RESULTS: While the signal-to-noise ratio (SNR) decreased (26+/-5 vs. 30+/-10; P=0.04) with the SENSE protocol, the image-quality scores for four identified segments of the RAs increased or were unchanged. The largest improvements in image quality occurred in the more distal segments of the RAs. Parenchymal ringing (P=0.005) and RA blurring (P=0.006) were significantly reduced, and there was a trend toward improvement of RA ringing despite the increased injection rate. CONCLUSION: The faster SENSE scan maintained nearly the same SNR (due to faster injection of Gd-chelate), reduced artifact levels, and improved image quality ratings for the distal renal vessels.

Aged↗

Intravascular hematocrit layering in equilibrium phase contrast-enhanced MR angiography of the peripheral vasculature.

PURPOSE: To evaluate intravenous hematocrit (HCT) layering detected in patent calf veins that potentially simulate filling defects seen in deep venous thrombosis (DVT). MATERIALS AND METHODS: Flow characteristics, vessel size, and enhancement patterns of veins with HCT layering were examined and compared with those of normal veins in vivo. Ex vivo studies were conducted with conventional and blood pool contrast agents to study the effects of MRI parameters and intrinsic variables on detecting HCT layering. RESULTS: HCT layering was detected in high resolution equilibrium phase images in one of six healthy subjects, and five of five patients with peripheral vascular occlusive disease (PVOD). Layering occurred only in deep veins that had significantly slower flow and larger diameter (P < 0.001) compared to normal veins. Enhancement patterns observed in vivo were similar to those found in the ex vivo study. CONCLUSION: The HCT layering effect in MR venography has not been previously reported, likely because delayed equilibrium phase venous imaging is not frequently performed. The use of blood pool contrast agents and high resolution equilibrium phase imaging allows intravascular HCT layering to be observed within a 30-60-minute time frame. Several imaging characteristics that distinguish HCT layering from DVT are discussed.

Adult↗

Accuracy of computed tomographic angiography and magnetic resonance angiography for diagnosing renal artery stenosis.

BACKGROUND: Timely, accurate detection of renal artery stenosis is important because this disorder may be a potentially curable cause of hypertension and renal impairment. OBJECTIVE: To determine the validity of computed tomographic angiography (CTA) and magnetic resonance angiography (MRA) compared with digital subtraction angiography (DSA) for detection of renal artery stenosis. DESIGN: Prospective multicenter comparative study conducted from 1998 to 2001. Two panels of 3 observers judged CTA and MRA image data and were blinded to all other results. Digital subtraction angiography images were evaluated by consensus. SETTING: 3 large teaching hospitals and 3 university hospitals in the Netherlands. PATIENTS: 402 hypertensive patients with suspected renal artery stenosis were included. A group of 356 patients who underwent all 3 diagnostic tests was used for analysis. MEASUREMENTS: Reproducibility was assessed by calculating interobserver agreement. Diagnostic performance was evaluated in terms of sensitivity, specificity, and other diagnostic variables. Atherosclerotic stenoses of 50% or greater and fibromuscular dysplasia were considered clinically relevant. RESULTS: Twenty percent of patients who underwent all 3 tests had clinically relevant renal artery stenosis. Moderate interobserver agreement was found, with kappa values ranging from 0.59 to 0.64 for CTA and 0.40 to 0.51 for MRA. The combined sensitivity and specificity were 64% (95% CI, 55% to 73%) and 92% (CI, 90% to 95%) for CTA and 62% (CI, 54% to 71%) and 84% (CI, 81% to 87%) for MRA. LIMITATIONS: Eighteen percent of the patients were included nonconsecutively. Digital subtraction angiography may be an imperfect reference test. CONCLUSION: Computed tomographic angiography and MRA are not reproducible or sensitive enough to rule out renal artery stenosis in hypertensive patients. Therefore, DSA remains the diagnostic method of choice. *For a list of the other investigators and research coordinators who participated in RADISH, see the Appendix.

Adult↗

Use of a three-station phased array coil to improve peripheral contrast-enhanced magnetic resonance angiography.

PURPOSE: To explore the imaging capabilities of a new commercially available, three-station, 129-cm long, 12-element phased array coil for contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with symptomatic peripheral arterial occlusive disease. MATERIALS AND METHODS: Nineteen patients, referred for peripheral CE-MRA, were evaluated using the new three-station coil. For each station four coil elements (two anterior and two posterior to the patient) were used. The expected improvements in signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were used to improve spatial resolution and increase anatomic coverage for the distal two stations compared to our previous protocol. Images obtained in the 19 patients imaged with the new coil were compared to those of the last 19 patients scanned without the use of the new coil. Differences in image quality before vs. after the availability of the new coil were compared in terms of SNR and CNR, subjective interpretability score (SIS), degree of venous enhancement, and anatomic coverage. Images were interpreted by two experienced observers, blinded for imaging technique and each other's results. RESULTS: Use of the coil enabled acquisition of high resolution peripheral vasculature images in all cases and allowed for substantially smaller voxel sizes (thighs: 5.3 vs. 8.4 mm(3) [-37%]; legs: 1.8 vs. 8.0 mm3 [-78%]) and much shorter acquisition durations in the aortoiliac and thigh stations (aortoiliac: 16 vs. 27 seconds [-41%]; thighs: 11 vs. 23 seconds [-52%]). Acquisition duration in the leg station was prolonged (68 vs. 29 seconds [+134%]). SNR and CNR were significantly higher only in the aortoiliac station using the three-station coil (both: P < 0.001). There were no significant differences in SIS for the aortoiliac and thigh stations (aortoiliac station: observer 1: P = 0.16, observer 2: P = 0.19; thigh station: both observers: P = 0.27). Images acquired with the new coil had significantly higher SIS for the leg station (both observers: P = 0.004). There were no significant differences in venous enhancement between the two protocols for any of the stations (all P > 0.11). In 12/12 (100%) requested cases the entire pedal arch was depicted using the new coil, whereas this was not possible with the old protocol. CONCLUSION: The new three-station dedicated peripheral vascular coil allows for much higher resolution imaging in the thigh and leg stations with greater anatomic coverage and substantially improves peripheral MRA quality of the lower leg vasculature.

Adult↗

Parallel imaging in MR angiography.

The recently developed techniques of parallel imaging with phased array coils are rapidly becoming accepted for magnetic resonance angiography (MRA) applications. This article reviews the various current parallel imaging techniques and their application to MRA. The increased scan efficiency provided by parallel imaging allows increased temporal or spatial resolution, and reduction of artifacts in contrast-enhanced MRA (CE-MRA). Increased temporal resolution in CE-MRA can be used to reduce the need for bolus timing and to provide hemodynamic information helpful for diagnosis. In addition, increased spatial resolution (or volume coverage) can be acquired in a breathhold (eg, in renal CE-MRA), or in otherwise limited clinically acceptable scan durations. The increased scan efficiency provided by parallel imaging has been successfully applied to CE-MRA as well as other MRA techniques such as inflow and phase contrast imaging. The large signal-to-noise ratio available in many MRA techniques lends these acquisitions to increased scan efficiency through parallel imaging.

Contrast Media↗

Increased pelvic vein thrombi in cryptogenic stroke: results of the Paradoxical Emboli from Large Veins in Ischemic Stroke (PELVIS) study.

BACKGROUND AND PURPOSE: Cryptogenic stroke is associated with an increased prevalence of patent foramen ovale. The Paradoxical Emboli From Large Veins in Ischemic Stroke (PELVIS) study hypothesized that patients with cryptogenic stroke have an increased prevalence of pelvic deep venous thrombosis (DVT). METHODS: At 5 sites, patients 18 to 60 years of age received an MRI venogram (MRV) of the pelvis within 72 hours of new symptom onset. Clinical data were then determined. Radiologists blinded to clinical data later read the scans. RESULTS: The 95 patients who met entry criteria were scanned. Their mean+/-SD age was 46+/-10 years, and time from stroke onset to pelvic MRV scan was 49+/-16 hours. Compared with those with stroke of determined origin (n=49), patients with cryptogenic stroke (n=46) were significantly younger, had a higher prevalence of patent foramen ovale (61% versus 19%), and had less atherosclerosis risk factors. Cryptogenic patients had more MRV scans with a high probability for pelvic DVT (20%) than patients with stroke of determined origin (4%, P<0.03), with most having an appearance of a chronic DVT. CONCLUSIONS: In this study of young stroke patients evaluated early after stroke, patients with cryptogenic stroke showed differences in several clinical features compared with patients with stroke of determined origin, including increased prevalence of pelvic DVT. The results require confirmation but suggest that paradoxical embolus from the pelvic veins may be the cause of stroke in a subset of patients classified as having cryptogenic stroke.

Adolescent↗

Paradoxical emboli from calf and pelvic veins in cryptogenic stroke.

PURPOSE: The increased prevalence of patent foramen ovale in patients with cryptogenic strokes suggests the occurrence of paradoxical embolism. The identification of deep venous thromboses (DVTs) in this population would strengthen this hypothesis. The purpose of this study was to image the subdiaphragmatic venous system in a cohort of patients with cryptogenic strokes. MATERIALS AND METHODS: In 37 patients with cryptogenic brain ischemia and interatrial communication, duplex studies of calf, popliteal, and femoral veins, and magnetic resonance imaging venograms of the pelvis veins were performed. RESULTS: In 10 patients, DVTs were diagnosed that were considered to be the cause of cryptogenic brain ischemia on probable (n = 6) or possible (n = 4) bases. In these patients, the median time from stroke to DVT was 3.25 days. In 5 of these 10 patients, DVTs did not involve popliteal and femoral veins, areas thought most important to pulmonary embolism, but instead were isolated to calf or pelvic veins. Although none of these 10 patients had abnormal blood hypercoagulation tests, 8 of the 10 did have clinical conditions suggesting predisposition to developing DVTs, such as concomitant neoplasms or pulmonary embolism. CONCLUSIONS: Increased evidence for paradoxical embolism may emerge when diagnostic strategies use multiple imaging methods and evaluate a broad extent of the subdiaphragmatic veins.

Adult↗

Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography.

PURPOSE: To use the parallel imaging technique, sensitivity encoding (SENSE), to increase spatial resolution and decrease venous contamination in peripheral magnetic resonance angiography (MRA). MATERIALS AND METHODS: Moving table, single-bolus peripheral contrast-enhanced (CE) -MRA was performed on nine patients. Manual table movement combined with SENSE in the upper station allowed for more rapid overall scan coverage such that acquisition of the lower station began 34 seconds after aortic contrast arrival. True sub- millimeter isotropic resolution was achieved in the lower station. RESULTS: Diagnostic MR angiograms of all three stations were obtained in all nine patients. Venous enhancement did not confound interpretation in any case. Sub-millimeter lower station resolution provided excellent vascular detail. CONCLUSION: Decreased delay time between upper and lower station acquisition in single bolus peripheral MR angiograms, now possible using parallel imaging techniques, combined with lower station sub-millimeter resolution may decrease venous contamination and increase overall interpretability, thus increasing clinical acceptance of peripheral MRA.

Humans↗

Motion of the distal renal artery during three-dimensional contrast-enhanced breath-hold MRA.

PURPOSE: To study the potential detrimental effects of renal motion on breath-hold three-dimensional contrast-enhanced (CE) magnetic resonance angiography (MRA). MATERIALS AND METHODS: A computer model simulating linear motion was applied to MRA pulse sequences. Subsequently, to study whether renal motion was present, 24 patients being evaluated for possible renovascular hypertension underwent a breath-hold nonenhanced single slice two-dimensional dynamic turbo field-echo magnetic resonance imaging (MRI) scan with a typical duration of 32 seconds. This sequence was followed by breath-hold three-dimensional CE renal MRA. CE-MRA images were evaluated by two independent observers. RESULTS: The computer model revealed linear renal motion to cause artifacts. The severity of these artifacts correlated with velocity. Significant (P < 0.001) near linear cranial motion of the kidneys and diaphragm during a sustained breath-hold was found for the right kidney, left kidney, right diaphragm, and left diaphragm (0.26 +/- 0.21 mm/second, 0.25 +/- 0.23 mm/second, 0.43 +/- 0.43 mm/second, and 0.29 +/- 0.33 mm/second [mean +/- SD], respectively). CE-MRA images showed artifacts of the distal renal artery that corroborated the computer model findings. CONCLUSION: The observed cranial motion of the kidneys during a breath-hold adversely affects distal renal artery image quality on three-dimensional CE-MRA and jeopardizes reliable clinical evaluation. Shortening scan time may be beneficial for decreasing image degradation caused by this phenomenon.

Adult↗

Separation of arteries and veins using flow-induced phase effects in contrast-enhanced MRA of the lower extremities.

In 3-D contrast-enhanced magnetic resonance (MR) angiography of the lower extremities the goal is most often to enhance arterial structures while keeping veins and surrounding tissue unenhanced. Imaging during steady-state concentration of a blood pool agent or during poor timing of an extra-cellular contrast medium may result in simultaneous venous enhancement, making interpretation of the angiogram difficult. The aim of this study was to develop a post-processing method to separate the arteries from the veins in standard contrast-enhanced MR angiograms. The method was based on the different accumulation of flow-induced phase in the arteries and veins of the lower extremities. The method was tested in both phantom experiments and volunteers undergoing 3-D contrast-enhanced MR angiography using both an extra-cellular contrast medium and a blood pool agent. In the phantom studies, opposite directional flow was successfully separated at mean flow velocities as low as 9 cm/s. In the volunteer studies, the larger veins were successfully extinguished while the larger arteries were left unaffected. In smaller vessels with low flow velocities the separation was less successful. This was most apparent in vessels not oriented superior-inferior. The method developed here is promising for separating arteries from veins in contrast-enhanced MR angiography although the results could be further improved by either a different pulse sequence design or combining this method with other segmentation methods.

Arteries↗

Morphologic and functional magnetic resonance imaging of renal artery stenosis: a multireader tricenter study.

The effect of combined morphologic and functional magnetic resonance (MR) imaging on the interobserver and intermodality variability for the grading of renal artery stenosis is assessed. In a randomized, blinded tricenter analysis, seven readers evaluated 43 renal arteries on x-ray digital subtraction angiography (DSA), 3D-Gadolinium MR angiography (3D-Gd-MRA), cine phase-contrast flow measurement (PC-flow), and a combined analysis of the last two. Interobserver variability was assessed for the grading of renal artery stenosis as well as regional vessel visibility. Intermodality variability for stenosis grading was analyzed in cases in which the readers agreed on the degree of stenosis in DSA. DSA had a substantial interobserver variability for the grading of stenosis (mean kappa kappa 0.64). 3D-Gd-MRA revealed a slightly improved interobserver variability but incorrectly graded 6 of 34 stenoses on a two-point scale (<50%, > or =50%). The combined approach of 3D-Gd-MRA and PC-flow revealed the best (P = 0.0003) interobserver variability (median kappa = 0.75) and almost perfect intermodality agreement with DSA (97% of cases). These findings were confirmed in a prospective analysis of 97 renal arteries. The vessel visibility of the renal artery ostium was significantly better in 3D-Gd-MRA than in DSA, whereas the visibility of the hilar and intrarenal vessels was significantly worse (P = 0.0001). A combined morphologic and functional MR examination significantly reduces interobserver variability and offers reliable and reproducible grading of renal artery stenosis based on stenosis morphology and hemodynamic changes. It can be considered a safe and noninvasive alternative for diagnostic DSA in cases that do not require assessment of intrarenal vessels.

Aged↗

Imaging primary and secondary tumor thrombus of the inferior vena cava: multi-detector computed tomography and magnetic resonance imaging.

Tumor thrombus of the inferior vena cava (IVC) is a severe medical condition with very poor prognosis unless the patient is treated with surgical resection. It can be caused by a primary leiomyosarcoma originating in the vessel wall or by intraluminal extension of tumor thrombus into the IVC from an adjacent organ. We reviewed 21 cases of tumoral thrombus in the IVC including primary leiomyosarcoma of the IVC (2 cases), renal cell carcinoma (14 cases), adrenocortical carcinoma (2 cases), primary adrenocortical leiomyosarcoma (1 case), hepatocellular carcinoma (1 case), and retroperitoneal metastasis (1 case). The most common findings of IVC tumor thrombus by multi-detector CT and magnetic resonance imaging will be discussed, including scanning protocols and the advantages and disadvantages of each method.

Adenocarcinoma↗