PubMed Health⌕ Search

Biomedical subjects

Jeffrey Hoorfar

Publications and source records attributed to Jeffrey Hoorfar.

At least 19 recordsLinked to original sources

Comparison of methods for detection of norovirus in oysters.

In the absence of culture methods for noroviruses, detection in foods relies on molecular techniques such as Reverse Transcription-Polymerase Chain Reaction (RT-PCR) on extracted viral RNA followed by PCR product confirmation by hybridisation and/or sequencing. However, in order to obtain a successful detection it is of great importance to remove the tissue inhibitors during the viral RNA extraction. To select the most efficient extraction procedure of oysters we have compared four protocols. A pool of digestive gland material from oyster samples was divided into 1.5 g portions and spiked with 10-fold dilutions of human faecal samples containing norovirus genogroup II. The samples were tested on three different occasions using four different sample treatment protocols. The protocols were assessed with regard to their ability to recover viral RNA and detect norovirus in spiked oysters and for their in-house reproducibility. One method using viral elution by a Mixer Mill Cell Disrupter resulted in a 10-fold better recovery than the other three protocols when an RT-seminested PCR (G2SKR/COG2F and G2SKR/G2SKF) detection approach was applied. Although less distinctive this was also the case when NoV was detected by a single round RT-PCR approach using the primers JV13i and JV12y. The second most efficient method was a method using chloroform extraction and polyethylene precipitation.

Animals↗

Quantification of Campylobacter spp. in chicken rinse samples by using flotation prior to real-time PCR.

Real-time PCR is fast, sensitive, specific, and can deliver quantitative data; however, two disadvantages are that this technology is sensitive to inhibition by food and that it does not distinguish between DNA originating from viable, viable nonculturable (VNC), and dead cells. For this reason, real-time PCR has been combined with a novel discontinuous buoyant density gradient method, called flotation, in order to allow detection of only viable and VNC cells of thermotolerant campylobacters in chicken rinse samples. Studying the buoyant densities of different Campylobacter spp. showed that densities changed at different time points during growth; however, all varied between 1.065 and 1.109 g/ml. These data were then used to develop a flotation assay. Results showed that after flotation and real-time PCR, cell concentrations as low as 8.6 x 10(2) CFU/ml could be detected without culture enrichment and amounts as low as 2.6 x 10(3) CFU/ml could be quantified. Furthermore, subjecting viable cells and dead cells to flotation showed that viable cells were recovered after flotation treatment but that dead cells and/or their DNA was not detected. Also, when samples containing VNC cells mixed with dead cells were treated with flotation after storage at 4 or 20 degrees C for 21 days, a similar percentage resembling the VNC cell fraction was detected using real-time PCR and 5-cyano-2,3-ditolyl tetrazolium chloride-4',6'-diamidino-2-phenylindole staining (20% +/- 9% and 23% +/- 4%, respectively, at 4 degrees C; 11% +/- 4% and 10% +/- 2%, respectively, at 20 degrees C). This indicated that viable and VNC Campylobacter cells could be positively selected and quantified using the flotation method.

Animals↗

A LightCycler real-time PCR hybridization probe assay for detecting food-borne thermophilic Campylobacter.

In a previous study, we reported the performance of a PCR assay amplifying 287-bp of the 16S rRNA gene of thermo-tolerant Campylobacter (C. jejuni, C. lari, C. coli) through an international ring-trial involving 12 participating laboratories. Based on the validated set of primers, a LightCycler real-time PCR assay (LC-PCR), which used fluorescent hybridization probes was developed. The test incorporated an internal amplification control co-amplified with the 16S rRNA gene of Campylobacter to monitor potential PCR inhibitors and ensure successful amplifications. The specificity study involving 39 Campylobacter and nine strains of other species indicated that the LC-PCR test was highly specific, giving cross-reactivity with only one strain of C. upsaliensis (CCUG19559). The sensitivity of the LC-PCR assay, evaluated in 32 spiked poultry-rinse or pork carcass-swab samples, was determined at 10CFU/ml carcass-rinse. The prevalence of samples positive for thermo-tolerant Campylobacter was 58.8% in 68 naturally contaminated poultry rinse samples tested by LC-PCR and the data were in good concordance with those of bacteriological method. The Ct values of the three replicates obtained for each sample tested in three different runs demonstrate that the LC-PCR was highly reproducible and afford a powerful tool for rapid detection of the thermo-tolerant Campylobacter strains.

Animals↗

Comparison of PCR-ELISA and LightCycler real-time PCR assays for detecting Salmonella spp. in milk and meat samples.

In a previous study, we reported the performance of a PCR assay amplifying 285-bp of the invA gene of Salmonella spp. through an international ring-trial involving four participating laboratories [Int. J. Food Microbiol. 89 (2003) 241]. Based on the validated set of primers and recent advancements in PCR technology, we have designed two specific PCR assays for detecting Salmonella spp. We have compared PCR-enzyme-linked immunosorbent assay (PCR-ELISA) and LightCycler real-time PCR assay (LC-PCR) with the standard ISO 6579 bacteriological reference method. The two PCR tests incorporated an internal amplification control (IAC) co-amplified with the invA gene of Salmonella to monitor potential PCR inhibitors and ensure successful amplification. The selectivity study involved 84 Salmonella and 44 non-Salmonella strains and the samples tested were represented by 60 artificially-contaminated samples of fish, minced beef and raw milk, and 92 naturally-contaminated milk and meat samples. When using either PCR-ELISA or LC-PCR assays, only Salmonella strains were detected. PCR-ELISA and LC-PCR assays gave with pure Salmonella cultures the same detection limit level of 10(3)CFU/ml, which corresponds respectively to 50 and 10 cells per PCR tube. Data on artificially contaminated samples indicated that both PCR methods were able to detect after enrichment less than five Salmonella cells in 25 g of food, giving 100% concordance with the ISO 6579 reference method. The results on naturally contaminated samples demonstrated that despite certain inhibition problems, LC-PCR and PCR-ELISA assays were highly specific and sensitive, and provide a powerful tool for detection of Salmonella in food samples.

Animals↗

Interlaboratory diagnostic accuracy of a Salmonella specific PCR-based method.

A collaborative study involving four European laboratories was conducted to investigate the diagnostic accuracy of a Salmonella specific PCR-based method, which was evaluated within the European FOOD-PCR project (http://www.pcr.dk). Each laboratory analysed by the PCR a set of independent obtained presumably naturally contaminated samples and compared the results with the microbiological culture method. The PCR-based method comprised a preenrichment step in buffered peptone water followed by a thermal cell lysis using a closed tube resin-based method. Artificially contaminated minced beef and whole broiler carcass-rinse resulted in a detection limit of less than 5 cells per 25 g meat or 100 ml broiler rinse. A total of 435 samples from four countries, including pig carcass swabs (n = 285), whole broiler carcass-rinse (n = 25), various raw meat (n = 33), and environmental samples (n = 92) were investigated. The interlaboratory diagnostic accuracy, i.e. diagnostic specificity and sensitivity, was shown to be 97.5%. The co-amplification of an internal amplification control indicated possible inhibitory substances derived from the sample. This work can contribute to the quality assurance of PCR-based diagnostic methods and is currently proposed as international standard document.

Animals↗

Standardization of diagnostic PCR for the detection of foodborne pathogens.

In vitro amplification of nucleic acids using the polymerase chain reaction (PCR) has become, since its discovery in the 1980s, a powerful diagnostic tool for the analysis of microbial infections as well as for the analysis of microorganisms in food samples. However, despite its potential, PCR has neither gained wide acceptance in routine diagnostics nor been widely incorporated in standardized methods. Lack of validation and standard protocols, as well as variable quality of reagents and equipment, influence the efficient dissemination of PCR methodology from expert research laboratories to end-user laboratories. Moreover, the food industry understandably requires and expects officially approved standards. Recognizing this, in 1999, the European Commission approved the research project, FOOD-PCR (http://www.PCR.dk), which aims to validate and standardize the use of diagnostic PCR for the detection of pathogenic bacteria in foods. The present review focuses on the harmonization procedure and standardization criteria for detection of foodborne pathogens by PCR. The progress of standardization so far and future perspectives of diagnostic PCR are discussed.

Bacteria↗

A rapid and direct real time PCR-based method for identification of Salmonella spp.

The aim of this work was the validation of a rapid, real-time PCR assay based on TaqMan technology for the unequivocal identification of Salmonella spp. to be used directly on an agar-grown colony. A real-time PCR system targeting at the Salmonella spp. invA gene was optimized and validated through a four times repeated blind experiment performed in two different laboratories including 50 Salmonella spp. with representative strains from each of the 5 different Salmonella subgenera and 30 non-Salmonella strains. Both parameters DeltaR(n) (fluorescence intensity of template through a normalized reporter value) and C(T) (cycle at which the fluorescence intensity achieved a pre-established threshold) were analyzed. Overall mean DeltaR(n) and C(T) values for Salmonella strains (2.14+/-0.87 and 15.30+/-0.90, respectively) were statistically different from values for non-Salmonella strains, allowing the establishment of cut-off DeltaR(n) and C(T) values based on 95% confidence intervals that allowed the correct identification of all strains tested in each independent experiment. The accuracy of this assay in terms of inclusivity and exclusivity was 100%. Moreover, the PCR system proved to be especially convenient because the pre-mix containing all PCR reagents except for the bacterial cells could be kept at -20 degrees C for at least 1 month before its use. The optimized TaqMan real-time PCR assay is a useful, simple and rapid method for routine identification of Salmonella spp., irrespective of the particular subgenus.

Bacterial Proteins↗

Multicenter validation of the analytical accuracy of Salmonella PCR: towards an international standard.

As part of a major international project for the validation and standardization of PCR for detection of five major food-borne pathogens, four primer sets specific for Salmonella species were evaluated in-house for their analytical accuracy (selectivity and detection limit) in identifying 43 Salmonella spp. and 47 non-Salmonella strains. The most selective primer set was found to be 139-141 (K. Rahn, S. A. De Grandis, R. C. Clarke, S. A. McEwen, J. E. Galán, C. Ginocchio, R. Curtiss III, and C. L. Gyles, Mol. Cell. Probes 6:271-279, 1992), which targets the invA gene. An extended determination of selectivity by using 364 strains showed that the inclusivity was 99.6% and the exclusivity was 100% for the invA primer set. To indicate possible PCR inhibitors derived from the sample DNA, an internal amplification control (IAC), which was coamplified with the invA target gene, was constructed. In the presence of 300 DNA copies of the IAC, the detection probability for primer set 139-141 was found to be 100% when a cell suspension containing 10(4) CFU/ml was used as the template in the PCR (50 CFU per reaction). The primer set was further validated in an international collaborative study that included 16 participating laboratories. Analysis with 28 coded ("blind") DNA samples revealed an analytical accuracy of 98%. Thus, a simple PCR assay that is specific for Salmonella spp. and amplifies a chromosomal DNA fragment detected by gel electrophoresis was established through extensive validation and is proposed as an international standard. This study addresses the increasing demand of quality assurance laboratories for standard diagnostic methods and presents findings that can facilitate the international comparison and exchange of epidemiological data.

Animals↗

Modeling of 5' nuclease real-time responses for optimization of a high-throughput enrichment PCR procedure for Salmonella enterica.

The performance of a 5' nuclease real-time PCR assay was studied to optimize an automated method of detection of preenriched Salmonella enterica cells in buffered peptone water (BPW). The concentrations and interactions of the PCR reagents were evaluated on the basis of two detection responses, the threshold cycle (C(T)) and the fluorescence intensity by a normalized reporter value (DeltaR(n)). The C(T) response was identified as the most suitable for detection modeling to describe the PCR performances of different samples. DNA extracted from S. enterica serovar Enteritidis was studied in double-distilled H2O (ddH2O) and in two different enrichment media (brain heart infusion and BPW) with two PCR mixtures based on AmpliTaq Gold or rTTH: A descriptive model was proposed and fitted to the available experimental data. Equivalent PCR performances for the two PCR mixtures were obtained when DNA was diluted in ddH2O. However, the level of detection of DNA was affected when BPW was present during amplification. Use of the rTth mixture generated a 1-log-unit wider linear range of amplification, and the DNA detection levels were 2 x 10(-13) g/microwell for the rTth mixture and 2 x 10(-12) g/microwell for the AmpliTaq Gold mixture. To verify the improved amplification capacity of the rTth mixture, BPW was inoculated with 1 CFU of S. enterica serovar Enteritidis per ml and the mixture was incubated at 30 degrees C. Samples for PCR were withdrawn every 4 h during a 36-h enrichment. Use of the rTth mixture resulted in an earlier PCR detection during enrichment than use of the AmpliTaq Gold mixture. For accurate detection (C(T) < or = 30) of S. enterica serovar Enteritidis inoculated in BPW, the rTth mixture required 8.4 h of enrichment, while the AmpliTaq Gold mixture needed 11.6 h. In conclusion, the principle applied can improve the methodology of 5' nuclease real-time PCR for numerical optimization of sample pretreatment strategies to provide automated diagnostic PCR procedures.

Animals↗

Diagnostic PCR: validation and sample preparation are two sides of the same coin.

Increased use of powerful PCR technology for the routine detection of pathogens has focused attention on the need for international validation and preparation of official non-commercial guidelines. Bacteria of epidemiological importance should be the prime focus, although a "validation infrastructure" once established could easily be adapted for PCR-based detection of viruses and parasites. The aim of standardization should be the widespread adoption of diagnostic PCR for routine pathogen testing. European experience provides the impetus for realization of this vision through preparation of quantitative reference DNA material and reagents, production of stringent protocols and tools for thermal cycler performance testing, uncomplicated sample preparation techniques, and extensive ring trials for assessment of the efficacy of selected matrix/pathogen detection protocols.

Humans↗