PubMed Health⌕ Search

Biomedical subjects

Jeffrey J Whicker

Publications and source records attributed to Jeffrey J Whicker.

6 recordsLinked to original sources

From dust to dose: Effects of forest disturbance on increased inhalation exposure.

Ecosystem disturbances that remove vegetation and disturb surface soils are major causes of excessive soil erosion and can result in accelerated transport of soils contaminated with hazardous materials. Accelerated wind erosion in disturbed lands that are contaminated is of particular concern because of potential increased inhalation exposure, yet measurements regarding these relationships are lacking. The importance of this was highlighted when, in May of 2000, the Cerro Grande fire burned over roughly 30% of Los Alamos National Laboratory (LANL), mostly in ponderosa pine (Pinus ponderosa) forest, and through areas with soils containing contaminants, particularly excess depleted and natural uranium. Additionally, post-fire thinning was performed in burned and unburned forests on about 25% of LANL land. The first goal of this study was to assess the potential for increased inhalation dose from uranium contaminated soils via wind-driven resuspension of soil following the Cerro Grande Fire and subsequent forest thinning. This was done through analysis of post-disturbance measurements of uranium air concentrations and their relationships with wind velocity and seasonal vegetation cover. We found a 14% average increase in uranium air concentrations at LANL perimeter locations after the fire, and the greatest air concentrations occurred during the months of April-June when wind velocities are highest, no snow cover, and low vegetation cover. The second goal was to develop a methodology to assess the relative contribution of each disturbance type towards increasing public and worker exposure to these resuspended soils. Measurements of wind-driven dust flux in severely burned, moderately burned, thinned, and unburned/unthinned forest areas were used to assess horizontal dust flux (HDF) in these areas. Using empirically derived relationships between measurements of HDF and respirible dust, coupled with onsite uranium soil concentrations, we estimate relative increases in inhalation doses for workers ranging from 15% to 38%. Despite the potential for increased doses resulting from these forest disturbances, the estimated annual dose rate for the public was <1 microSv yr(-1), which is far below the dose limits for public exposures, and the upper-bound dose rate for a LANL worker was estimated to be 140 microSv yr(-1), far below the 5 x 10(4) microSv yr(-1) occupational dose limit. These results show the importance of ecosystem disturbance in increasing mobility of soil-bound contaminants, which can ultimately increase exposure. However, it is important to investigate the magnitude of the increases when deciding appropriate strategies for management and long-term stewardship of contaminated lands.

Air Pollutants, Radioactive↗

Increased wind erosion from forest wildfire: implications for contaminant-related risks.

Assessments of contaminant-related human and ecological risk require estimation of transport rates, but few data exist on wind-driven transport rates in nonagricultural systems, particularly in response to ecosystem disturbances such as forest wildfire and also relative to water-driven transport. The Cerro Grande wildfire in May of 2000 burned across ponderosa pine (Pinus ponderosa Douglas ex P.&C. Lawson var. scopulorum Englem.) forest within Los Alamos National Laboratory in northern New Mexico, where contaminant transport and associated post-fire inhalation risks are of concern. In response, the objectives of this study were to measure and compare wind-driven horizontal and vertical dust fluxes, metrics of transport related to wind erosion, for 3 yr for sites differentially affected by the Cerro Grande wildfire: unburned, moderately burned (fire mostly confined to ground vegetation), and severely burned (crown fire). Wind-driven dust flux was significantly greater in both types of burned areas relative to unburned areas, by more than one order of magnitude initially and by two to three times 1 yr after the fire. Unexpectedly, the elevated dust fluxes did not decrease during the second and third years in burned areas, apparently because ongoing drought delayed post-fire recovery. Our estimates enable assessment of amplification in contaminant-related risks following a major type of disturbance-wildfire, which is expected to increase in intensity and frequency due to climate change. More generally, our results highlight the importance of considering wind- as well as water-driven transport and erosion, particularly following disturbance, for ecosystem biogeochemistry in general and human and ecological risk assessment in particular.

Air Pollutants↗

Characterization of plutonium aerosol collected during an accident.

This study determined the plutonium particle size distribution and dissolution rate of PuO2 aerosol collected during the 16 March 2000 release of an undetermined amount of PuO2 in a room within a plutonium facility at Los Alamos National Laboratory. The facility has been in operation since 1978 to support the development, fabrication, and testing of Pu heat sources for the U.S. Department of Energy. Several workers were in the room at the time of the release and in vivo study of five of the workers began the day after the exposure event. Four of the subjects subsequently received chelation therapy. Over 30 fixed air filter samplers (FASs) and four continuous air monitors (CAMs) were operating in the room during the radiological release. One 47-mm-diameter glass fiber FAS filter and one 25-cm-diameter mixed cellulose ester CAM filter containing Pu aerosol from the incident were examined in the study described here. Total alpha radioactivity on the filters was determined by gross alpha counting. Isotopic identification of the Pu was made by alpha spectrometry. Film autoradiography was used to characterize the spatial distribution of alpha-emitting particles on the filters. Track-etch autoradiography was used to estimate the distribution of alpha radioactivity in individual plutonium particles on the filters for particle size measurement. The glass fiber filter was then cut into six sections. Particles from two sections were resuspended in alcohol, dispersed as an aerosol using a Lovelace nebulizer, and characterized by aerodynamic diameter using a Lovelace Multi-jet cascade impactor. The measured activity median aerodynamic diameter from the cascade impactor was 4.8 mum with a geometric standard deviation of 1.5. That agreed with the size distribution obtained from the alpha track detection technique. The remaining four filter sections were used in an in vitro dissolution study with synthetic serum ultrafiltrate. The retention of undissolved Pu was consistent with a biphasic exponential function. The majority of the Pu dissolved with a half-time of 900 d. The information on particle size distribution and solubility from this study was useful in assigning a radiation dose to the exposed workers, supporting the decision to administer chelation therapy, and providing a model for characterizing accident-associated aerosols in the future.

Aerosols↗

A quantitative method for optimized placement of continuous air monitors.

Alarming continuous air monitors (CAMs) are a critical component for worker protection in facilities that handle large amounts of hazardous materials. In nuclear facilities, continuous air monitors alarm when levels of airborne radioactive materials exceed alarm thresholds, thus prompting workers to exit the room to reduce inhalation exposures. To maintain a high level of worker protection, continuous air monitors are required to detect radioactive aerosol clouds quickly and with good sensitivity. This requires that there are sufficient numbers of continuous air monitors in a room and that they are well positioned. Yet there are no published methodologies to quantitatively determine the optimal number and placement of continuous air monitors in a room. The goal of this study was to develop and test an approach to quantitatively determine optimal number and placement of continuous air monitors in a room. The method we have developed uses tracer aerosol releases (to simulate accidental releases) and the measurement of the temporal and spatial aspects of the dispersion of the tracer aerosol through the room. The aerosol dispersion data is then analyzed to optimize continuous air monitor utilization based on simulated worker exposure. This method was tested in a room within a Department of Energy operated plutonium facility at the Savannah River Site in South Carolina, U.S. Results from this study show that the value of quantitative airflow and aerosol dispersion studies is significant and that worker protection can be significantly improved while balancing the costs associated with CAM programs.

Aerosols↗

Influence of room geometry and ventilation rate on airflow and aerosol dispersion: implications for worker protection.

Knowledge of dispersion rates and patterns of radioactive aerosols and gases through workrooms is critical for understanding human exposure and for developing strategies for worker protection. The dispersion within rooms can be influenced by complex interactions between numerous variables, but especially ventilation design and room furnishings. For this study, dependence of airflow and aerosol dispersion on workroom geometry (furnishings) and ventilation rate were studied in an experimental room that was designed to approximate a plutonium laboratory. Three different configurations of simulated gloveboxes and two ventilation rates (approximately 6 and 12 air exchanges per hour) were studied. A sonic anemometer was used to measure airflow parameters including all three components of air velocity vectors and turbulence intensity distributions at multiple locations and heights. Aerosol dispersion rates and patterns were measured by releasing aerosols multiple times from six different locations. Aerosol particle concentrations resolved in time and space were measured using 16 multiplexed laser particle counters. Comparisons were made of air velocities, turbulence, and aerosol transport across different ventilation rates and room configurations. A strong influence of ventilation rate on aerosol dispersion rates and air velocity was found, and changes in room geometry had significant effects on aerosol dispersion rates and patterns. These results are important with regards to constant evaluation of placement of air sampling equipment, benchmarking numerical models of room airflow, and design of ventilation and room layouts with consideration of worker safety.

Aerosols↗

Temporal and spatial variation of episodic wind erosion in unburned and burned semiarid shrubland.

Redistribution of soil, nutrients, and contaminants is often driven by wind erosion in semiarid shrublands. Wind erosion depends on wind velocity (particularly during episodic, high-velocity winds) and on vegetation, which is generally sparse and spatially heterogeneous in semiarid ecosystems. Further, the vegetation cover can be rapidly and greatly altered due to disturbances, particularly fire. Few studies, however, have evaluated key temporal and spatial components of wind erosion with respect to (i) erosion rates on the scale of weeks as a function of episodic high-velocity winds, (ii) rates at unburned and burned sites, and (iii) within-site spatial heterogeneity in erosion. Measuring wind erosion in unburned and recently burned Chihuahuan desert shrubland, we found (i) weekly wind erosion was related more to daily peak wind velocities than to daily average velocities as consistent with our findings of a threshold wind velocity at approximately 7 m s(-1); (ii) greater erodibility in burned vs. unburned shrubland as indicated by erosion thresholds, aerodynamic roughness, and nearground soil movement; and (iii) burned shrubland lost soil from intercanopy and especially canopy patches in contrast to unburned shrubland, where soil accumulated in canopy patches. Our results are among the first to quantify post-fire wind erosion and highlight the importance of accounting for finer temporal and spatial variation in shrubland wind erosion. This finer-scale variation relates to semiarid land degradation, and is particularly relevant for predictions of contaminant resuspension and redistribution, both of which historically ignore finer-scale temporal and spatial variation in wind erosion.

Conservation of Natural Resources↗