Publications and source records attributed to Jeffrey L Duerk.

At least 19 recordsLinked to original sources

Toward rapid high resolution in vivo intravascular MRI: evaluation of vessel wall conspicuity in a porcine model using multiple imaging protocols.

PURPOSE: To assess magnetic resonance (MR) pulse sequences for high resolution intravascular imaging. MATERIALS AND METHODS: Intravascular imaging of the abdominal aorta and iliac arteries was performed in vivo in a porcine model at 1.5 T using catheter-mounted micro-receive coils. Ten protocols, including spin-echo (SE)-echo planar imaging (SE-EPI), segmented EPI, half-Fourier single-shot turbo spin-echo (HASTE), fast imaging with steady-state free precession (TrueFISP), turbo spin-echo (TSE), and SE acquisition schemes were employed in 13 trials. Images were analyzed by six expert raters with respect to wall-conspicuity, wall-to-lumen/tissue contrast, visible layers of the arterial wall, anticipated clinical usefulness, and overall image quality. Mean differences between sequence-types were evaluated using analysis of variance (ANOVA) between groups with planned comparisons. RESULTS: The vessel wall was delineated in almost all protocols. Motion artifacts from physiological and device motion were reduced in fast techniques. The best contrast between the wall and surrounding tissue was provided by a HASTE protocol. Anatomic layers of the vessel wall were best depicted on dark blood T2-weighted TSE. Overall, TrueFISP was ranked highest on the remaining measures. CONCLUSION: Dedicated catheter-coils combined with fast sequences have potential for in vivo characterization of vessel walls. TrueFISP offered the best overall image quality and acquisition speed, but suffered from the inability to delineate the multiple layers of the wall, which seems associated with dark blood- and T2-weighted contrast. We believe future intra-arterial trials should proceed from this study in normal artery imaging and initially focus on fast T2-weighted dark blood techniques in trials with pathology.

Analysis of Variance↗

Image-guided and -monitored renal artery stenting using only MRI.

PURPOSE: To demonstrate the ability of a unique interventional MR system to be used safely and effectively as the only imaging modality for all phases of MR-guided stent-supported angioplasty. MATERIALS AND METHODS: An experimental disease model of renal stenosis was created in six pigs. An interventional MR system, which employed previously reported tools for real-time catheter tracking with automated scan-plane positioning, adaptive image parameters, and radial true-FISP imaging with steady-state precession (True-FISP) imaging coupled with a high-speed reconstruction technique, was then used to guide all phases of the intervention, including: guidewire and catheter insertion, stent deployment, and confirmation of therapeutic success. Pre- and postprocedural X-ray imaging was used as a gold standard to validate the experimental results. RESULTS: All of the stent-supported angioplasty interventions were a technical success and were performed without complications. The average postoperative residual stenosis was 14.9%. The image guidance enabled the stents to be deployed with an accuracy of 0.98 +/- 0.69 mm. Additionally, using this interventional MRI system to guide renal artery stenting significantly reduces the procedure time, as compared to using X-ray fluoroscopy. CONCLUSION: This study has clearly demonstrated the first successful treatment of renal artery stenting in an experimental animal model solely under MRI guidance and monitoring.

Angioplasty↗

Blood attenuation with SSFP-compatible saturation (BASS).

PURPOSE: To investigate a rapid flow-suppression method for improving the contrast-to-noise ratio (CNR) between the vessel wall and the lumen for cardiovascular imaging applications. MATERIALS AND METHODS: In this study a new dark-blood steady-state free precession (SSFP) sequence utilizing two excitation pulses per TR was developed. The first pulse is applied immediately adjacent to the slice of interest, while the second is a conventional slice-selective pulse designed to excite an SSFP signal for the static spins in the slice of interest. The slice-selective pulse is followed by fully refocused gradients along all three imaging axes over each TR. The signal amplitude (SA) from the moving spins excited by the "saturation" pulse is attenuated since they are not fully refocused at the TE. RESULTS: This work provides confirmation, by both simulation and experiments, that modest adaptations of the basic True-FISP structure can limit unwanted "bright blood" signal within the vessels while simultaneously preserving the contrast and speed advantages of this well-established rapid imaging method. CONCLUSION: Animal imaging trials confirm that dark-blood contrast is achieved with the BASS sequence, which substantially reverses the lumen-to-muscle CNR of a conventional True-FISP "bright blood" acquisition from 14.77 (bright blood) to -13.96 (dark blood) with a modest increase (24.2% of regular TR of SSFP for this implementation) in acquisition time to accommodate the additional slab-selective excitation pulse and gradient pulses.

Animals↗

Model-free parameters from dynamic contrast-enhanced-MRI: sensitivity to EES volume fraction and bolus timing.

PURPOSE: To quantify the unknown relative sensitivities of semiquantitative measures from dynamic contrast-enhanced (DCE) MRI to variations in the volume fraction V(e) of the extravascular extracellular space (EES), and the duration of the contrast injection. MATERIALS AND METHODS: Tissue-uptake curves were simulated across various values of F, PS, V(e), and bolus timings, with and without additive noise and at different image reacquisition rates. From each, the peak of the first derivative (G(peak)), the total uptake after the rapid first phase (CE), and the IAUC were calculated and plotted against F for each experimental condition. Relationships between each measure and the corresponding quantitative measure K(trans) were also examined, particularly for linearity. RESULTS: The highest sensitivity to flow was achieved for shorter bolus timings for G(peak), CE, and IAUC. G(peak) and IAUC were most linearly related to K(trans). The sensitivity to V(e) was lowest for G(peak), followed by IAUC and CE. Long sampling intervals resulted in severe underestimation of G(peak), while IAUC was unaffected provided that the limits of integration were properly applied. G(peak) could not be properly calculated in the presence of noise without a prior smoothing of the acquired curves, while IAUC was again unaffected by noise. CONCLUSION: G(peak) and IAUC are both useful model-free analogs of blood flow (i.e., K(trans)) for pre- and posttreatment comparisons. G(peak) may be the better choice in cases where larger changes in V(e) are likely, but only if sufficient noise reduction and fast image sampling are applied. If V(e) is expected to remain stable, IAUC is superior to G(peak) by virtue of its stability in the face of noise and more reliable estimation over a wider range of sampling rates.

Contrast Media↗

In vivo cardiovascular catheterization under real-time MRI guidance.

PURPOSE: To test the hypothesis that cardiac and coronary catheterization can be successfully performed under real-time MR guidance using a conventional x-ray angiographic catheter. MATERIALS AND METHODS: Cardiac and coronary catheterization was conducted on eight farm pigs using a real-time True FISP sequence. A pigtail catheter was used for both left- and right-heart catheterizations performed on all eight animals, while an Amplatz or Judkins catheter was used for the right coronary catheterization that was attempted on five animals. The intravascular devices were visualized by means of their native susceptibility artifacts. For right coronary artery catheterizations, 25% diluted gadolinium (Gd) contrast material was injected to confirm engagement of the right coronary artery. RESULTS: Cardiac catheterization of both the right- and left-heart chambers was successfully performed in all eight pigs. In addition, right coronary catheterization was successfully completed in four of the five pigs in which it was attempted. The procedure time for cardiac catheterization was one minute, while the time range required for coronary catheterization was 32-91 minutes. CONCLUSION: This work demonstrates that MRI-guided cardiac catheterization using conventional X-ray angiographic catheters is feasible; however, coronary catheterization with this passive-tracking technique is limited.

Animals↗

Bunched phase encoding (BPE): a new fast data acquisition method in MRI.

A new fast data acquisition method, "Bunched Phase Encoding" (BPE), is presented. In conventional rectilinear data acquisition, only a readout gradient (and no phase encoding gradient) is applied when k-space data are acquired. Reduction of the number of phase encoding lines by increasing the phase encoding step size often leads to aliasing artifacts. Papoulis's generalized sampling theory asserts that in some cases aliasing artifact-free signals can be reconstructed even if the Nyquist criterion is violated in some regions of the Fourier domain. In this study, Papoulis's theoretical construct is exploited to reduce the number of acquired phase encoding lines. To achieve this, k-space data are sampled along a "zigzag" trajectory during each readout; samples are acquired at a sampling frequency higher than that of the normal rectilinear acquisition. The total number of TR cycles and, hence, the total scan time can be reduced. The resultant signal-to-noise ratio (SNR) often varies across the reconstructed image when using the BPE technique, and the image SNR depends on the reconstruction method. This work is comparable to a gradient based version of parallel imaging. Evidence suggests it may serve as the basis for new opportunities for fast data acquisition in MRI.

Image Interpretation, Computer-Assisted↗

Deformable and rigid registration of MRI and microPET images for photodynamic therapy of cancer in mice.

We are investigating imaging techniques to study the tumor response to photodynamic therapy (PDT). Positron emission tomography (PET) can provide physiological and functional information. High-resolution magnetic resonance imaging (MRI) can provide anatomical and morphological changes. Image registration can combine MRI and PET images for improved tumor monitoring. In this study, we acquired high-resolution MRI and microPET 18F-fluorodeoxyglucose (FDG) images from C3H mice with RIF-1 tumors that were treated with Pc 4-based PDT. We developed two registration methods for this application. For registration of the whole mouse body, we used an automatic three-dimensional, normalized mutual information algorithm. For tumor registration, we developed a finite element model (FEM)-based deformable registration scheme. To assess the quality of whole body registration, we performed slice-by-slice review of both image volumes; manually segmented feature organs, such as the left and right kidneys and the bladder, in each slice; and computed the distance between corresponding centroids. Over 40 volume registration experiments were performed with MRI and microPET images. The distance between corresponding centroids of organs was 1.5 +/- 0.4 mm which is about 2 pixels of microPET images. The mean volume overlap ratios for tumors were 94.7% and 86.3% for the deformable and rigid registration methods, respectively. Registration of high-resolution MRI and microPET images combines anatomical and functional information of the tumors and provides a useful tool for evaluating photodynamic therapy.

Animals↗

An augmented reality system for MR image-guided needle biopsy: initial results in a swine model.

PURPOSE: To evaluate an augmented reality (AR) system in combination with a 1.5-T closed-bore magnetic resonance (MR) imager as a navigation tool for needle biopsies. MATERIALS AND METHODS: The experimental protocol had institutional animal care and use committee approval. Seventy biopsies were performed in phantoms by using 20 tube targets, each with a diameter of 6 mm, and 50 virtual targets. The position of the needle tip in AR and MR space was compared in multiple imaging planes, and virtual and real needle tip localization errors were calculated. Ten AR-guided biopsies were performed in three pigs, and the duration of each procedure was determined. After successful puncture, the distance to the target was measured on MR images. The confidence limits for the achieved in-plane hit rate and for lateral deviation were calculated. A repeated measures analysis of variance was used to determine whether the placement error in a particular dimension (x, y, or z) differed from the others. RESULTS: For the 50 virtual targets, a mean error of 1.1 mm +/- 0.5 (standard deviation) was calculated. A repeated measures analysis of variance indicated no statistically significant difference (P > .99) in the errors in any particular orientation. For the real targets, all punctures were inside the 6-mm-diameter tube in the transverse plane. The needle depth was within the target plane in 11 biopsy procedures; the mean distance to the center of the target was 2.55 mm (95% confidence interval: 1.77 mm, 3.34 mm). For nine biopsy procedures, the needle tip was outside the target plane, with a mean distance to the edge of the target plane of 1.5 mm (range, 0.07-3.46 mm). In the animal experiments, the puncture was successful in all 10 cases, with a mean target-needle distance of 9.6 mm +/- 4.85. The average procedure time was 18 minutes per puncture. CONCLUSION: Biopsy procedures performed with a combination of a closed-bore MR system and an AR system are feasible and accurate.

Animals↗

EB1089, a vitamin D receptor agonist, reduces proliferation and decreases tumor growth rate in a mouse model of hormone-induced mammary cancer.

1,25-Dihydroxyvitamin D3 and several of its analogs, such as EB1089, induce growth arrest and apoptosis of breast cancer cells in culture. EB1089 has also been shown to limit growth of xenografts in nude mice and carcinogen-induced mammary tumors in rats. Coupled with the fact that the vitamin D receptor is highly expressed in a large proportion of breast tumors, these data suggest that it may be a broad spectrum therapeutic target. We utilized a transgenic model of hormone-induced mammary cancer, the LH-overexpressing mouse, to assess, for the first time, the efficacy of EB1089 in a spontaneous tumor model. Similar to human breast cancers, the pre-neoplastic mammary glands and mammary tumors in these mice express high levels of vitamin D receptor. Treatment with EB1089 decreased proliferation of mammary epithelial cells in pre-neoplastic glands by 35%. Moreover, half of hormone-induced mammary tumors treated with EB1089 demonstrated a decreased rate of growth, with a subset of these tumors even regressing, suggesting that 1,25-dihydroxyvitamin D3 analogs may be effective chemopreventive and chemotherapeutic agents for breast cancer.

Animals↗

Multislice MR first-pass myocardial perfusion imaging: impact of the receiver coil array.

PURPOSE: To compare a new 12-element body phased-array coil with a conventional four-element surface receiver coil array to provide increased signal-to-noise ratios (SNRs) for cardiac steady state free precession (SSFP) perfusion imaging. MATERIALS AND METHODS: Thirteen consecutive patients were included in the study. Patients were examined both with a four-element surface coil array and a 12-element body coil array. First-pass myocardial perfusion imaging using saturation recovery SSFP was acquired during antecubital injection of Gd-DTPA. Imaging parameters: TR 2.8 msec/TE 1.3 msec, flip angle 50 degrees , bandwidth 960 Hz/pixel and half-Fourier acquisition. SNR was calculated using six regions of interest (ROI) for the myocardial perfusion scans. Calculations of corresponding ROIs using the two different coil setups were compared using analysis of variance (ANOVA). Semiquantitative perfusion parameters were calculated for both groups. RESULTS: The mean SNR in myocardial perfusion imaging increased by 21% using the 12-element coil setup (P < 0.001) when compared to the four-element coil. ROI comparisons revealed an increased signal inhomogeneity with the 12-element coil when compared to four-element coil experiments. Absolute normal range values of semiquantitative perfusion parameters were consistently higher using the 12-element coil setup (P < 0.001). CONCLUSION: The 12-element coil array provides higher SNR, but these improvements come with trade-offs in image homogeneity. Increased SNR translates into higher semiquantitative perfusion values and offers the potential for improved detection of perfusion defects.

Adult↗

Combined use of the intravascular blood-pool agent, gadomer, and carbon dioxide: a novel type of double-contrast magnetic resonance angiography (MRA).

PURPOSE: To evaluate the combined use of carbon dioxide (CO(2)) and a gadolinium-based blood-pool agent for magnetic resonance angiography (MRA). MATERIALS AND METHODS: After an initial intravenous injection of the blood-pool agent Gadomer (Schering AG, Germany), repeated transcatheter CO(2) injections were performed in the aorta and the renal arteries of two fully-anesthetized pigs. Real-time images were acquired using a true fast imaging with steady-state precession (FISP) sequence. RESULTS: During the CO(2) injections, the Gadomer-enhanced blood was totally replaced, resulting in an immediate, temporary, total signal loss in the vessel lumen. Susceptibility artifacts during the injections or catheter manipulations rarely occurred. CONCLUSION: Due to T1-shortening, the circulating blood-pool agent prevents flow artifacts during catheter manipulations because the steady-state is reached much earlier. Therefore, this double-contrast MRA method improves catheter conspicuity and might be helpful for guiding and controlling intravascular procedures during interventional MRI.

Animals↗

Functional magnetic resonance imaging of the human lumbar spinal cord.

PURPOSE: To determine whether consistent regions of activity could be observed in the lumbar spinal cord of single subjects with spin-echo functional MRI (fMRI) if several repeated experiments were performed within a single imaging session. MATERIALS AND METHODS: Repeated fMRI experiments of the human lumbar spinal cord were performed at 1.5 T with a single-shot spin-echo technique (half-Fourier single-shot turbo spin-echo (HASTE)) as used by previous investigators, and a modified method (fluid-attenuated inversion recovery (FLAIR)-HASTE) that nulled the otherwise highly variable signal from the cerebrospinal fluid (CSF). RESULTS: FLAIR-HASTE reduced the variability of the signal in the CSF region to background levels, and presumably reduced associated artifacts in the spinal cord. Consistent areas of activation in the spinal cord in response to a thermal stimulus just below the knee were not observed across the fMRI experiments with either method. CONCLUSION: FLAIR-HASTE was useful for removing artifact in the spinal cord signal induced by variability in the CSF signal. However, with the techniques used in this study, we were not able to confirm the presence of a consistent fMRI response in the lumbar spinal cord because of the signal enhancement by extravascular protons (SEEP) effect during thermal stimulation of the hindlimb.

Adult↗

Semiautomatic nonrigid registration for the prostate and pelvic MR volumes.

RATIONALE AND OBJECTIVES: Three-dimensional (3D) nonrigid image registration for potential applications in prostate cancer treatment and interventional magnetic resonance (iMRI) imaging-guided therapies were investigated. MATERIALS AND METHODS: An almost fully automated 3D nonrigid registration algorithm using mutual information and a thin plate spline (TPS) transformation for MR images of the prostate and pelvis were created and evaluated. In the first step, an automatic rigid body registration with special features was used to capture the global transformation. In the second step, local feature points (FPs) were registered using mutual information. An operator entered only five FPs located at the prostate center, left and right hip joints, and left and right distal femurs. The program automatically determined and optimized other FPs at the external pelvic skin surface and along the femurs. More than 600 control points were used to establish a TPS transformation for deformation of the pelvic region and prostate. Ten volume pairs were acquired from three volunteers in the diagnostic (supine) and treatment positions (supine with legs raised). RESULTS: Various visualization techniques showed that warping rectified the significant pelvic misalignment by the rigid-body method. Gray-value measures of registration quality, including mutual information, correlation coefficient, and intensity difference, all improved with warping. The distance between prostate 3D centroids was 0.7 +/- 0.2 mm after warping compared with 4.9 +/- 3.4 mm with rigid-body registration. CONCLUSION: Semiautomatic nonrigid registration works better than rigid-body registration when patient position is changed greatly between acquisitions. It could be a useful tool for many applications in the management of prostate.

Algorithms↗

MR imaging-guided percutaneous angioplasty and stent placement in a swine model comparison of open- and closed-bore scanners.

RATIONALE AND OBJECTIVES: The purpose of this study is to compare the feasibility and precision of renal artery angioplasty and stent placement using two different MR scanners. MATERIALS AND METHODS: MR imaging-guided angioplasty and stent placements were performed on seven pigs using 0.2 and 1.5 T scanners (Magnetom Open and Magnetom Sonata, Siemens Medical Solutions, Erlangen, Germany). For guidance of catheters, guide wires and stents susceptibility artifact-based tracking was used. The end point of each intervention was to position a stent in the renal artery with its proximal end at the level of the aortic wall. Procedure time and stent position were evaluated. RESULTS: Catheterization, angioplasty, and stent placement were feasible using MRI guidance at both 0.2 and 1,5 Tesla. At 1.5 T all catheter manipulations and interventions were performed in less than 30 minutes. At 0.2 T the interventions took up to 90 minutes. No significant difference in the stent deviation was noted between the two scanners. CONCLUSION: The use of a high-performance 1.5 T scanner helped to reduce the procedure time to half of that of a low-field system. Since no difference in stent placement precision was noted, a dedicated MR-stent might be mandatory for more precise stent placement.

Angioplasty, Balloon↗

A review of technical advances in interventional magnetic resonance imaging.

Initial research in the development of interventional magnetic resonance (MR) imaging in the late 1980s and early to mid-1990s focused on pulse sequences, devices, and clinical applications. This focus was largely a result of the limited number of areas in which the academic research community leading the development could provide innovation on the MR systems of the time. However, during the past decade, computational power, higher bandwidth graphical displays, faster computer networks, improved pulse sequence architectures, and improved technical specifications have accelerated the pace of development on modern MR systems. Today, it is the combination of multiple system factors that are enabling the future of interventional MR. These developments, their impact on the field, and newly emerging applications are described.

Animals↗

MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects.

Reliable visualization and tracking are essential for guiding endovascular devices within blood vessels. The most commonly used methods are susceptibility artifact-based tracking that relies on the artifact created within the image by the device and microcoil- or antenna-based tracking that uses the high signal generated by small MR endovascular receive coils when the transmit coil emits a nonselective radiofrequency pulse. To date, the use of endovascular MR guidance techniques has primarily been confined to animal experiments. There are only a few reports on MR-guided endovascular applications in patients. Therefore, access to the patient within the scanner, dedicated devices, and safety issues remain major challenges. To face these challenges, attention from all radiologists, especially interventional radiologists, is required to make MR-guided endovascular procedures a clinical reality.

Animals↗

Update to pulse sequences for interventional MR imaging.

The motivations for developing MR-guided minimally invasive therapy include its excellent soft tissue contrast, tomographic imaging in any direction (as opposed to projection imaging as in fluoroscopy), the absence of ionizing radiation,the abundance of contrast mechanisms (including bright blood pulse sequences that lead to excellent vessel conspicuity without exogenous contrast agent injection), the ability to obtain physiologic information such as perfusion, and an overall excellent safety profile. The main pulse sequences used today for interventional MR imaging are T1/T2-weighted FISP and TrueFISP, T2-weighted turbo spin-echo, and T1-weighted FLASH. The specific clinical question, the underlying pathophysiology,and the procedure to be performed dictate which sequence is used. Each of these sequences has been written to acquire data in conventional rectilinear trajectories, radial k-space paths, or even spirals. In many ways, the questions being researched in interventional MR imaging have been dictated by the primary issues in greatest need of resolution or that most directly facilitate new clinical development. A decade ago, research focused on exploration of new scan strategies for contrast and temporal resolution. Advancements in the last decade have made it possible to acquire and display greater than 10 images per second in realtime with millimeter resolution in all three directions. This temporal and spatial resolution is considered high enough to guide most interventions. With this capability, other research has focused on instrument tracking. The field has gone from the capability to track a single coil and superimpose it on a previously acquired roadmap to systems that follow, adapt, and provide high-resolution images due to the advent of multichannel receiver systems, improved graphics, higher processor speeds, and increases in speed and quantity of memory. Hence, instruments can be reliably identified and tracked and the information can be used to update pulse sequence parameters in real time, thereby opening new opportunities for interventional MR imaging that extend from biopsy and thermal therapy to image-guided vascular and cardiac procedures. Today, we see such issues as RF heating of wires used for device localization and the noise generated by rapid switching of MR gradients being significant obstacles yet to overcome to allow the full strength of MR-guided interventions to be realized clinically. It is anticipated that these topics will emerge as critical concepts in the next decade of interventional MR imaging research.

Algorithms↗

Functional cardiac CT and MR: effects of heart rate and software applications on measurement validity.

This study sought to validate different software applications for cardiac function analysis using ECG-gated CT and MR datasets in correlation with underlying heart rate. Ten patients and a set of ventricular phantoms underwent concurrent multislice-CT and cine-MR imaging for evaluation of cardiac function. Datasets from both imaging modalities were evaluated utilizing 2 volumetric analysis tools to determine left ventricular volume and mass. Initially, intraobserver measurement variability was assessed. Detected measurement variability was correlated with underlying absolute magnitude of cardiac volumes and masses. Subsequently, results were statistically evaluated by determining significant data variability depending on imaging modality and choice of evaluation software. Finally, the data variability was correlated with underlying heart rates. This study showed that all analyzed datasets uniformly presented intraobserver variations below 2%, and variability was not related to the magnitude of measurement. Significant measurement accuracy was proven in all calculated parameters obtained from the cardiac phantoms. Acquired patient datasets and calculated functional parameters showed significant data homogeneity, with measurement variability coefficients ranging from 0.935-0.955. CT datasets showed maximal data variability at heart rates below 60 BpM. MR datasets showed maximal data variability at heart rates above 90 BpM. In conclusion, CT and MR datasets allowed an interchangeable utilization of volumetric analysis tools. However, reliable volumetric analysis was limited to an optimal range of cardiac rates for each modality, thus emphasizing the necessity of reporting volumetric measurement results in combination with heart rate to allow for consideration of this possible cause for measurement variation.

Adolescent↗