PubMed Health⌕ Search

Biomedical subjects

Jeffrey L Krolik

Publications and source records attributed to Jeffrey L Krolik.

4 recordsLinked to original sources

Isolation and minimization of head motion-induced signal variations in fMRI data using independent component analysis.

Task-related head movement during acquisition of fMRI data represents a serious confound for both motion correction and estimates of task-related activation. Cost functions implemented in most conventional motion-correction algorithms compare two volumes for similarity but fail to account for signal variability that is not due to motion (e.g., brain activation). We therefore recently proposed the theoretical basis for a novel method for fMRI motion correction, termed motion-corrected independent component analysis (MCICA), that allows for brain activation present in an fMRI time-series to be implicitly modeled and mitigates motion-induced signal changes without having to directly estimate the motion parameters (Liao et al., IEEE Transactions on Medical Imaging 2005;25:29-44). To explore the effects of non-movement-related signal changes on registration error, we performed several previously proposed test simulations (Freire et al., IEEE Transactions on Medical Imaging 2002;21:470-484) to evaluate the performance of MCICA and compare it with the conventional square-of-difference-based measures such as LS-SPM and LS-AIR. We demonstrate that for both simulated data and real fMRI images, the proposed MCICA method performs favorably. Specifically, in simulations MCICA was more robust to the addition of simulated activation, and did not lead to the detection of false activations after correction for simulated task-correlated motion. With actual data from a motor fMRI experiment, the time course of the derived continually task-related ICA component became more correlated with the underlying behavioral task after preprocessing with MCICA compared to other methods, and the associated activation map was more clustered in the primary motor and supplementary motor cortices without spurious activation at the brain edge. We conclude that assessing the statistical properties of a motion-corrupted volume in relation to other volumes in the series, as is done with MCICA, is an accurate means of differentiating between motion-induced signal changes and other sources of variability in fMRI data.

Algorithms↗

An information-theoretic criterion for intrasubject alignment of FMRI time series: motion corrected independent component analysis.

A three-dimensional image registration method for motion correction of functional magnetic resonance imaging (fMRI) time-series, based on independent component analysis (ICA), is described. We argue that movement during fMRI data acquisition results in a simultaneous increase in the joint entropy of the observed time-series and a decrease in the joint entropy of a nonlinear function of the derived spatially independent components calculated by ICA. We propose this entropy difference as a reliable criterion for motion correction and refer to a method that maximizes this as motion-corrected ICA (MCICA). Specifically, a given motion-corrupted volume may be corrected by determining the linear combination of spatial transformations of the motion-corrupted volume that maximizes the proposed criterion. In essence, MCICA consists of designing an adaptive spatial resampling filter which maintains maximum temporal independence among the recovered components. In contrast with conventional registration methods, MCICA does not require registration of motion-corrupted volumes to a single reference volume which can introduce artifacts because corrections are applied without accounting for variability due to the task-related activation. Simulations demonstrate that MCICA is robust to activation level, additive noise, random motion in the reference volumes and the exact number of independent components extracted. When the method was applied to real data with minimal estimated motion, the method had little effect and, hence, did not introduce spurious changes in the data. However, in a data series from a motor fMRI experiment with larger motion, preprocessing the data with the proposed method resulted in the emergence of activation in primary motor and supplementary motor cortices. Although mutual information (MI) was not explicitly optimized, the MI between all subsequent volumes and the first one was consistently increased for all volumes after preprocessing the data with MCICA. We suggest MCICA represents a robust and reliable method for preprocessing of fMRI time-series corrupted with motion.

Algorithms↗

Matched-field depth estimation for active sonar.

This work concerns the problem of estimating the depth of a submerged scatterer in a shallow-water ocean by using an active sonar and a horizontal receiver array. As in passive matched-field processing (MFP) techniques, numerical modeling of multipath propagation is used to facilitate localization. However, unlike passive MFP methods where estimation of source range is critically dependent on relative modal phase modeling, in active sonar source range is approximately known from travel-time measurements. Thus the proposed matched-field depth estimation (MFDE) method does not require knowledge of the complex relative multipath amplitudes which also depend on the unknown scatterer characteristics. Depth localization is achieved by modeling depth-dependent relative delays and elevation angle spreads between multipaths. A maximum likelihood depth estimate is derived under the assumption that returns from a sequence of pings are uncorrelated and the scatterer is at constant depth. The Cramér-Rao lower bound on depth estimation mean-square-error is computed and compared with Monte Carlo simulation results for a typical range-dependent, shallow-water Mediterranean environment. Depth estimation performance to within 10% of the water column depth is predicted at signal-to-noise ratios of greater than 10 dB. Real data results are reported for depth estimation of an echo repeater to within 10-m accuracy in this same shallow water environment.

Journal Article↗

The performance of matched-field track-before-detect methods using shallow-water Pacific data.

Matched-field track-before-detect processing, which extends the concept of matched-field processing to include modeling of the source dynamics, has recently emerged as a promising approach for maintaining the track of a moving source. In this paper, optimal Bayesian and minimum variance beamforming track-before-detect algorithms which incorporate a priori knowledge of the source dynamics in addition to the underlying uncertainties in the ocean environment are presented. A Markov model is utilized for the source motion as a means of capturing the stochastic nature of the source dynamics without assuming uniform motion. In addition, the relationship between optimal Bayesian track-before-detect processing and minimum variance track-before-detect beamforming is examined, revealing how an optimal tracking philosophy may be used to guide the modification of existing beamforming techniques to incorporate track-before-detect capabilities. Further, the benefits of implementing an optimal approach over conventional methods are illustrated through application of these methods to shallow-water Pacific data collected as part of the SWellEX-1 experiment. The results show that incorporating Markovian dynamics for the source motion provides marked improvement in the ability to maintain target track without the use of a uniform velocity hypothesis.

Acoustics↗