PubMed Health⌕ Search

Biomedical subjects

Jeffrey M Liebmann

Publications and source records attributed to Jeffrey M Liebmann.

At least 19 recordsLinked to original sources

Visual field and intraocular pressure asymmetry in the low-pressure glaucoma treatment study.

OBJECTIVE: To explore the relationship between asymmetric baseline intraocular pressure (IOP) and asymmetric visual field (VF) loss in the Low-Pressure Glaucoma Treatment Study. DESIGN: Randomized, multicenter, controlled clinical trial. PARTICIPANTS: Low-pressure glaucoma (LPG) patients 30 years or older were identified. Exclusion criteria included an untreated pressure > 21 mmHg, advanced VF loss, and contraindications to study medications. INTERVENTIONS: A baseline VF was created using the average of 2 reliable Humphrey full-threshold examinations. A baseline diurnal IOP curve was performed without IOP-lowering medication. MAIN OUTCOME MEASURES: Mean diurnal, peak, trough, IOP range (peak - trough), and standard deviation (SD) of IOP measurements, and mean deviation (MD) and corrected pattern SD (CPSD) of VF examinations. RESULTS: One hundred ninety patients were enrolled (mean age, 64.9+/-10.7 years). Mean deviation and CPSD were not correlated with mean, peak, trough, or peak minus trough (P - T) IOP (Ps = 0.2-0.9). Among patients with unilateral VF loss (n = 53 [27.9%]), there were no differences (Ps = 0.3-0.9) in any IOP parameter between the normal VF eye and fellow glaucomatous eyes. Among patients with bilateral VF loss (n = 137 [72.1%]), mean, peak, trough, and P - T IOPs were similar in eyes with a better VF MD compared with eyes with a worse VF MD (Ps = 0.2-0.7). Cross-classified contingency tables demonstrated no relationship (Ps = 0.1-0.3) between IOP and VF MD or CPSD using chi-square analysis. CONCLUSIONS: Intraocular pressure asymmetry is unrelated to VF asymmetry in the Low-Pressure Glaucoma Treatment Study, suggesting an unclear pathogenic relationship between IOP and glaucomatous damage in eyes with LPG.

Adrenergic alpha-Agonists↗

Imaging of the optic disc and retinal nerve fiber layer in acute optic neuritis.

PURPOSE: To demonstrate whether optical coherence tomography (OCT-3) and scanning laser ophthalmoscopy (HRT-2) can be used to measure changes of the optic disc and peripapillary retinal nerve fiber layer (RNFL) in eyes with acute retrobulbar optic neuritis that have no clinically apparent optic disc swelling. To correlate these findings with presentation magnetic resonance imaging (MRI) of the affected optic nerve. METHODS: Eight consecutive patients with acute retrobulbar optic neuritis, who had no prior optic neuritis in either eye, were prospectively investigated at presentation and at between 1 and 3 months with clinical examination, OCT-3, HRT-2. At presentation, MRI of the optic nerves were performed in 7/8 patients. RESULTS: Compared to unaffected eyes, affected eyes without clinically seen optic disc swelling at baseline, there was a non-significant trend to increased thickness in the total RNFL, superior and nasal measurements. Baseline HRT in affected eyes showed smaller mean cup to disc ratio (p=0.003) and a smaller cup area (p=0.002) compared with the unaffected eye. The MRI-demonstrated optic nerve lesion did not correlate with OCT RNFL thickening or HRT decrease of the physiological cup. Follow-up imaging of the affected eyes showed normalization of HRT cup size parameters and OCT RNFL thickness (p<0.04). At follow-up, the temporal RNFL had thinning in 7/8 affected eyes (46.8 mum, p=0.021) compared with fellow unaffected eyes (57.8 mum), which did not change. CONCLUSION: OCT-3 and HRT demonstrate mild RNFL thickening or optic disc swelling in acute optic neuritis, even when swelling is not seen clinically. OCT-3 appears to reveal measurable RNFL thinning in the temporal quadrant after retrobulbar optic neuritis, even though vision improves. RNFL imaging may be useful in future studies of residual injury after optic neuritis.

Acute Disease↗

Angle closure in highly myopic eyes.

PURPOSE: Patients with angle-closure glaucoma and high myopia are uncommon. We evaluated the clinical characteristics of all patients with angle closure and high myopia in our database and propose possible mechanisms for angle closure in these atypical patients. DESIGN: Retrospective noncomparative case series. PARTICIPANTS: Our database of 17938 patients was searched for patients with myopia of spherical equivalent of more than -6.0 diopters and angle closure. Data recorded included age at time of initial consultation, gender, slit-lamp examination results, gonioscopy results, biometric parameters, ultrasound biomicroscopy results (from 1993 onward), clinical diagnosis, and therapy. RESULTS: Twenty patients (11 females, 9 males) were identified. Mean age at the time of consultation was 52.9+/-19.3 years. Angle-closure diagnoses included primary pupillary block (9 patients), pupillary block in an eye with keratoconus (1 patient), pupillary block secondary to a pupillary membrane associated with retinopathy of prematurity (1 patient), plateau iris configuration and syndrome (3 patients), phacomorphic glaucoma in Weill-Marchesani syndrome (2 patients), malignant glaucoma secondary to a scleral buckle (2 patients), miotic-induced angle closure (1 patient), and Marfan syndrome (1 patient). CONCLUSIONS: Angle closure can occur in eyes with high myopia. Causes of angle closure other than relative pupillary block are more common than in the general angle-closure glaucoma population. Careful gonioscopy accompanied by biometry and ultrasound biomicroscopy can lead to the correct diagnosis and individualized management in these eyes.

Adult↗

Ultrasound biomicroscopy in asymmetric pigment dispersion syndrome and pigmentary glaucoma.

OBJECTIVE: To identify differences in anterior chamber anatomy among patients with asymmetric pigment dispersion syndrome and no other discernible cause for the asymmetry. METHODS: Ultrasound biomicroscopy and A-scan biometry were performed on both eyes of 13 patients with asymmetric pigment dispersion syndrome without a known cause for asymmetric involvement. A radial perpendicular image in the horizontal temporal meridian detailing the scleral spur, angle anatomy, and iris configuration was obtained for each eye by 2 examiners. RESULTS: There were no differences in lens thickness (P = .33), refractive error (P = .84), or axial length (P = .99) between more and less affected eyes. However, the mean +/- SD iris concavity (P<.001), iris-lens contact distance (P = .02), and distance from the scleral spur to the iris insertion (0.42 +/- 0.11 vs 0.29 +/- 0.06 mm) (P = .002) were greater in the more affected eye of each patient. CONCLUSION: A more posterior iris insertion predisposes to the phenotypic expression of pigment dispersion syndrome.

Adult↗

The ISNT rule and differentiation of normal from glaucomatous eyes.

OBJECTIVE: To determine whether the ISNT rule (that normal eyes show a characteristic configuration for disc rim thickness of inferior > or = superior > or = nasal > or = temporal), widely used for clinical evaluation of the optic nerve head, can differentiate normal from glaucomatous eyes. METHODS: All subjects underwent complete eye examination, including achromatic automated perimetry, simultaneous stereoscopic disc photography, and confocal scanning laser ophthalmoscopy. Subjects with normal eyes had no evidence of glaucoma or ocular hypertension and had normal perimetry measurements. Subjects with glaucoma had a reproducible visual field defect. One eye from each subject was randomly enrolled. The ISNT rule was assessed by masked evaluation of disc photographs at the 3, 6, 9, and 12 o'clock positions. RESULTS: Sixty-six subjects with normal eyes (33 black and 33 white individuals) and 43 with open-angle glaucoma (15 black and 28 white individuals) were enrolled. The ISNT rule was intact in 52 (79%) of 66 normal eyes and 12 (28%) of 43 glaucomatous eyes (P<.001). Multiple logistic regression indicated that the odds ratio for glaucoma associated with violation of the ISNT rule was 6.04 (95% confidence interval, 1.74-20.95) after adjustment for age; race was not a confounder of this association. CONCLUSION: The ISNT rule is useful in differentiating normal from glaucomatous optic nerves and is unaffected by race.

Adult↗

Effect of eye testing order on automated perimetry results using the Swedish Interactive Threshold Algorithm standard 24-2.

OBJECTIVE: To evaluate whether the order of eye testing affects the mean deviation (MD) or the test reliability of visual field testing using the Swedish Interactive Threshold Algorithm (SITA) standard 24-2. METHODS: Consecutive patients with manifest or suspect glaucoma with 2 prior sets of SITA standard 24-2 test results performed on the right eye first were enrolled. A subsequent test was performed on the left eye first. For each eye, the MD and the test reliability indexes (> or = 20%) were compared among the 3 successive examinations. RESULTS: Forty-seven patients (29 women and 18 men; mean +/- SD age, 70.6 +/- 11.9 years) were enrolled. The MD +/- SD was -5.83 +/- 5.43 dB OD and -5.46 +/- 4.86 dB OS. There was no statistically significant difference in the MD or the test reliability among the 3 test results for either eye. Fixation loss was responsible for the unreliable fields in almost all cases. CONCLUSIONS: Among this cohort of patients experienced with automated perimetry in a glaucoma subspecialty practice, changing the order of eye testing using the SITA standard 24-2 did not have a significant effect on the MD or the test reliability. Intereye fatigue may not be clinically significant with this algorithm. Fixation loss remains a problem with the use of this algorithm.

Aged↗

Identification of retained nucleus fragment in the posterior chamber using ultrasound biomicroscopy.

PURPOSE: To describe the use of ultrasound biomicroscopy (UBM) to image retained nuclear fragments posterior to the iris plane after uncomplicated phacoemulsification with posterior chamber intraocular lens (PCIOL) implantation in two patients. DESIGN: Interventional case report. METHODS: Two patients presented with an iris elevation after uncomplicated phacoemulsification and lens implantation. RESULTS: Visual acuity was 20/20 in the first patient and 20/30 in the second. There was no anterior chamber inflammation in either eye. UBM revealed a small, retained nuclear fragment between the iris pigment epithelium and the anterior lens capsule, causing localized anterior iris displacement in both patients. The PCIOL was within the capsular bag, and the iris root and ciliary body were normal in both patients. CONCLUSION: UBM can demonstrate retained lens fragments within the posterior chamber.

Aged↗

Measurements of optic disk size with HRT II, Stratus OCT, and funduscopy are not interchangeable.

PURPOSE: To assess the interchangeability of optic disk size measurements using slit-lamp funduscopy, optical coherence tomography (OCT-3), and confocal scanning laser ophthalmoscopy (HRT-II) in clinical practice. DESIGN: Prospective nonrandomized clinical study. METHODS: Measurements of vertical disk diameter (VDD) were obtained with the three methods. Disk area was obtained from OCT and HRT printouts. True agreement between methods in measuring VDD was assessed using Bland-Altman graphs and 95% limits of agreement (LoA). Disks were classified as small, average, or large, and agreement between methods in this classification was assessed using kappa statistics. RESULTS: Forty-eight patients were enrolled (mean age 53.4 +/- 14.3 years). VDD (mean +/- SD) was 1.58 +/- 0.15, 1.70 +/- 0.22, and 1.90 +/- 0.24 mm with funduscopy, HRT, and OCT, respectively. Very large LoA were observed: -0.29 to 0.70 mm for OCT and HRT, -0.07 to 0.71 mm for OCT and funduscopy, and -0.29 to 0.53 mm for HRT and funduscopy. There was poor agreement (kappa < 0.4) in classification of disk size as small, average, or large whether disk diameter or area was compared and using two definitions of disk size. CONCLUSIONS: We observed a large range of differences in estimating disk size with HRT, OCT, and funduscopy. This precludes interchangeable use of these measurements in clinical practice, and does not allow simple conversion formulas to be proposed. In addition, there is poor agreement between these methods in classifying disk size as small, average, or large. At present, estimation of both absolute and relative disk size can only be defined separately for each measurement modality.

Anthropometry↗

Rescue of failed filtering blebs with ab interno trephination.

We evaluated the effectiveness of ab interno automated trephination as a technique for rescuing failed mature filtering blebs. A retrospective chart review of 40 failed blebs of 38 patients who had a posttrephination follow-up period of at least 3 months was done. With success defined as intraocular pressure (IOP) <21 mm Hg and at least a 20% reduction from baseline on the same or fewer number of pretrephination medications, 30/40 eyes (75%) fit these criteria over the entire course of follow-up. Among all 40 eyes, there was a significant reduction of IOP from pretrephination to 3 months (P<.001). The percentage of patients requiring 2 or more medications declined from 90% pretrephination to 21% at 3 months (P<.0001), and was stable thereafter. Some patients were able to eliminate all medications. Patients who did not meet the criteria of success regained successful IOP control with other modalities of management. Complications were few. We believe that ab interno trephination is an excellent option for rescuing selected failed filtering blebs.

Adult↗

Detecting early functional damage in glaucoma suspect and ocular hypertensive patients with the multifocal VEP technique.

PURPOSE: To determine whether the multifocal visual evoked potential (mfVEP) technique can detect early functional damage in ocular hypertensive (OHT) and glaucoma suspect (GS) patients with normal standard achromatic automated perimetry (SAP) results. PATIENTS AND METHODS: Twenty-five GS patients (25 eyes), 25 patients with OHT (25 eyes), and 50 normal controls (50 eyes) were enrolled in this study. All GS, OHT and normal control eyes had normal SAP as defined by a pattern standard deviation and mean deviation within the 95% confidence interval and a glaucoma hemifield test within normal limits on the Humphrey visual field 24-2 program. Eyes with GS had optic disc changes consistent with glaucoma with or without raised intraocular pressure (IOP), and eyes with OHT showed no evidence of glaucomatous optic neuropathy and IOPs >or=22 mm Hg. Monocular mfVEPs were obtained from both eyes of each subject using a pattern-reversal dartboard array with 60 sectors. The entire display had a radius of 22.3 degrees. The mfVEPs, for each eye, were defined as abnormal when either the monocular or interocular probability plot had a cluster of 3 or more contiguous points with P<0.05 and at least 2 of these points with P<0.01. RESULTS: The mfVEP results were abnormal in 4% of the eyes from normal subjects. Abnormal mfVEPs were detected in 20% of the eyes of GS patients and 16% of the eyes of OHT patients. Significantly more mfVEP abnormalities were detected in GS patients than in normal controls. However, there was no significant difference in mfVEP results between OHT patients and normal controls. CONCLUSIONS: The mfVEP technique can detect visual field deficits in a minority of eyes with glaucomatous optic disks and normal SAP results.

Disease Progression↗

Assessment of a race-specific normative HRT-III database to differentiate glaucomatous from normal eyes.

PURPOSE: To determine if a new, normative, race-specific database enhances the ability of confocal scanning laser ophthalmoscopy to differentiate normal from glaucomatous eyes. METHODS: One eye of eligible normal and glaucoma patients was enrolled. All subjects underwent a complete ophthalmologic examination, standard achromatic perimetry (SITA-SAP, 24-2), and confocal scanning laser ophthalmoscopy [Heidelberg retinal tomograph (HRT-II)] within 1 month of enrollment. Racial groups were defined by self-report. Glaucoma was defined by the existence of reproducible SAP loss (pattern standard deviation <5% and/or Glaucoma Hemifield Test outside normal limits) on 2 consecutive fields. Normal subjects had 2 normal visual fields (pattern standard deviation >5% and Glaucoma Hemifield Test within 97% normal limits) and a normal clinical examination. HRT-II examinations were exported to the HRT-III software, which includes a large race-specific normative database consisting of 733 white and 215 black eyes. Moorfields regression analysis (MRA) for the most abnormal optic disc sector was compared between the HRT-II (MRA2) and the HRT-III software before (MRA3-B) and after (MRA3-A) adjustment for race. Sectors outside the 99.9% confidence interval limits ("outside normal limits") were determined to be abnormal. RESULTS: We enrolled 124 black (52 glaucoma, 72 normal) and 96 white (32 glaucoma, 64 normal) subjects. Mean age was 51+/-13 years and 50+/-16 years for blacks and whites, respectively (P = 0.45). Visual field mean deviation was -7.3+/-6.7 db for glaucomatous eyes and -0.4+/-1.1 db for normal eyes (P < 0.001). Sensitivity and specificity for the HRT-II was 71.9% and 95.3%, respectively, for white subjects and 50.0% and 98.6%, respectively, for black subjects. Using the expanded HRT-III database, analysis yielded a sensitivity of 81.3% and specificity of 93.8% for whites and a sensitivity of 71.2% and specificity of 86.1% for blacks. After an adjustment for black ethnicity was made in the HRT-III program, the sensitivity and specificity for blacks was 65.4% and 90.3%, respectively. CONCLUSIONS: A new, larger, race-specific HRT-III database increases sensitivity while maintaining specificity for whites and increases sensitivity but decreases specificity for blacks. New software and databases based on race require careful scrutiny before use in clinical practice.

Adult↗

A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma.

PURPOSE: To describe an approach for the evaluation of covariate effects on receiver operating characteristic (ROC) curves and to apply this methodology to the investigation of the effects of disease severity and age on the diagnostic performance of frequency doubling technology (FDT) and standard automated perimetry (SAP) visual function tests for glaucoma detection. METHODS: The study included 370 eyes of 211 participants, with 174 eyes of 110 patients having glaucomatous optic neuropathy and 196 eyes of 101 subjects being normal. All patients underwent visual function testing with FDT 24-2 Humphrey Matrix and SAP SITA (Carl Zeiss Meditec, Inc., Dublin, CA). Disease severity was evaluated by the amount of neuroretinal rim loss assessed by confocal scanning laser ophthalmoscopy. An ROC regression model was fitted to evaluate the influence of disease severity and age on the diagnostic performance of the pattern SD (PSD) index from FDT 24-2 and SAP SITA. RESULTS: After adjustment for age, the areas under the ROC curves (AUCs) for SAP SITA PSD for 10%, 30%, 50%, and 70% loss of neuroretinal rim area were 0.638, 0.756, 0.852, and 0.920, respectively. Corresponding values for FDT 24-2 PSD were 0.766, 0.857, 0.922, and 0.962. For 10% and 30% rim loss, FDT 24-2 PSD had a significantly larger AUC than did SAP SITA PSD. CONCLUSIONS: A regression methodology to evaluate covariate effects on ROC curves can be useful for assessment of diagnostic tests in glaucoma. Using the proposed methodology, a significantly better performance of FDT 24-2 compared to SAP SITA for diagnosis of early glaucoma was demonstrated.

Age Factors↗

A comparison between multifocal and conventional VEP latency changes secondary to glaucomatous damage.

PURPOSE: To compare latencies of conventional visual evoked potentials (cVEPs) and multifocal VEPs (mfVEPs) in the same patients. Previous reports of prolonged cVEP latency suggest a vehicle for detecting abnormal ganglion cells and for monitoring neuroprotection. METHODS: Seventy-five glaucomatous eyes (47 patients), 75 eyes with suspected glaucoma (46 patients), and 41 control eyes (22 subjects) underwent achromatic automated perimetry and mfVEP and cVEP testing. The mfVEP stimulus was a scaled dart board with 60 sectors; each sector was a pattern-reversing checkerboard. The cVEP stimulus was a reversing checkerboard with checks of either 15 minutes or 60 minutes in width. RESULTS: Relatively few glaucomatous eyes had latencies that fell outside the range of control eyes, and there was little difference between the cVEP and mfVEP results. In the glaucoma group, 12.3% (15 minutes cVEP), 8% (60 minutes cVEP), and 17.3% (mfVEP) of the eyes and 5.3% (15 minutes cVEP), 6.7% (60 minutes cVEP), and 5.3% (mfVEP) of the suspect eyes exceeded the normal range. The glaucomatous eyes had, on average, relatively small increases in latency, compared with the control or suspect groups. Further, the latency of both the mfVEP and cVEP bore no obvious relationship to the mean deviation of the visual field. CONCLUSIONS: Contrary to previous reports, prolonged VEP delays were present in a minority of patients with glaucoma. Either a delayed VEP is not a good indicator of damaged, as opposed to dead, retinal ganglion cells, or there are relatively few patients who exhibit evidence of damaged ganglion cells.

Adolescent↗

Differences in visual function and optic nerve structure between healthy eyes of blacks and whites.

OBJECTIVE: To investigate differences in visual function, optic disc topography, and retinal nerve fiber layer (RNFL) thickness between healthy eyes of blacks and whites. METHODS: Visual function was assessed in healthy eyes of 50 blacks and 50 whites using standard automated perimetry, short-wavelength automated perimetry, and frequency doubling technology perimetry. Optic disc topography and RNFL thickness were measured using the Heidelberg Retina Tomograph and the optical coherence tomograph. RESULTS: Mean standard automated perimetry mean deviations were within the normal range for both groups. Blacks had worse mean deviation values than whites using frequency doubling technology perimetry (mean +/- SD, -1.8 +/- 3.2 dB vs -0.1 +/- 2.4 dB), blacks had larger optic disc areas than whites using the Heidelberg Retina Tomograph (mean +/- SD, 2.1 +/- 0.4 mm2 vs 1.7 +/- 0.4 mm2), the RNFL of blacks was thicker than that of whites by 16.91 microm superiorly and 10.10 microm inferiorly using optical coherence tomography, and blacks had slightly higher intraocular pressures than whites (mean +/- SD, 16.5 +/- 2.5 mm Hg vs 15.2 +/- 3.2 mm Hg) and thinner central corneas (mean +/- SD, 540.5 +/- 43.2 microm vs 560.9 +/- 35.5 microm). No racial differences were found in mean RNFL thickness, pattern standard deviation on all tests, or any of the short-wavelength automated perimetry variables. CONCLUSIONS: Minimal racial differences in visual function were found, but race significantly affected optic disc topography and superior and inferior RNFL thickness measurements in healthy eyes. The racial differences observed for intraocular pressure could theoretically increase after correcting for central corneal thickness. Prospective studies are needed to further investigate these findings.

Anthropometry↗

Baseline topographic optic disc measurements are associated with the development of primary open-angle glaucoma: the Confocal Scanning Laser Ophthalmoscopy Ancillary Study to the Ocular Hypertension Treatment Study.

OBJECTIVE: To determine whether baseline confocal scanning laser ophthalmoscopy (CSLO) optic disc topographic measurements are associated with the development of primary open-angle glaucoma (POAG) in individuals with ocular hypertension. METHODS: Eight hundred sixty-five eyes from 438 participants in the CSLO Ancillary Study to the Ocular Hypertension Treatment Study with good-quality baseline CSLO images were included in this study. Each baseline CSLO parameter was assessed in univariate and multivariate proportional hazards models to determine its association with the development of POAG. RESULTS: Forty-one eyes from 36 CSLO Ancillary Study participants developed POAG. Several baseline topographic optic disc measurements were significantly associated with the development of POAG in both univariate and multivariate analyses, including larger cup-disc area ratio, mean cup depth, mean height contour, cup volume, reference plane height, and smaller rim area, rim area to disc area, and rim volume. In addition, classification as "outside normal limits" by the Heidelberg Retina Tomograph classification and the Moorfields Regression Analysis classifications (overall, global, temporal inferior, nasal inferior, and superior temporal regions) was significantly associated with the development of POAG. Within the follow-up period of this analysis, the positive predictive value of CSLO indexes ranged from 14% (Heidelberg Retina Tomograph classification and Moorfields Regression Analysis overall classification) to 40% for Moorfields Regression Analysis temporal superior classification. CONCLUSIONS: Several baseline topographic optic disc measurements alone or when combined with baseline clinical and demographic factors were significantly associated with the development of POAG among Ocular Hypertension Treatment Study participants. Longer follow-up is required to evaluate the true predictive accuracy of CSLO measures.

False Positive Reactions↗

Ciliary body thickness increases with increasing axial myopia.

PURPOSE: To assess the relationship between ciliary body thickness and refractive error. DESIGN: Prospective observational case series. METHODS: We enrolled 75 eyes of 75 patients with no history of intraocular surgery or use of anti-glaucoma medication. Axial length was measured by A-scan ultrasonography. Ciliary body thickness (CBT) was measured by two masked observers on radial-section images of the temporal corneoscleral limbus, acquired with ultrasound biomicroscopy (UBM) at 2 and 3 mm posterior to the scleral spur (CBT2 and CBT3, respectively). RESULTS: Refractive error was inversely correlated with CBT2 and CBT3 (r = -.64 and r = -.52, P < .0001, respectively). Axial length was correlated with CBT (r = .66 and r = .57, P < .0001, for CBT2 and CBT3, respectively). CONCLUSION: CBT increases with increasing myopia and axial length.

Body Weights and Measures↗

Assessment of central corneal thickness using optical coherence tomography.

PURPOSE: To demonstrate the capability of model OCT3 optical coherence tomographer to evaluate central corneal thickness (CCT) in normal human corneas in vivo and compare the results with the those of standard ultrasound (US) pachymetry and Orbscan. SETTING: New York Eye & Ear Infirmary Resident Clinic, New York, New York, USA. METHODS: The CCT in 22 eyes of 11 subjects was determined with the OCT3 (Carl Zeiss Meditec), Orbscan (Bausch & Lomb, Inc.), and US pachymetry (DGH Technology, Inc.). Three central corneal scans of each eye were obtained using the OCT3. First, OCT3 data were processed using the standard OCT software program (OCT3(std)). Second, OCT3 raw data were exported and measurements were repeated using Scion Image for Windows program (OCT3(sci)). The OCT3 and Orbscan results were compared with the mean of 5 US pachymetry measurements in each eye. RESULTS: The OCT3(std), OCT3(sci), and Orbscan CCT measurements showed high correlations with US pachymetry (r=0.981, r=0.984, and r=0.942, respectively; P<.0001). Bland-Altman analysis showed a high level of agreement between US pachymetry and OCT3 techniques but not Orbscan. High repeatability for OCT3(std) (r(2)=0.05) and OCT3(sci) (r(2)=0.01) was also seen. CONCLUSION: Results show the OCT3 is an accurate, noninvasive, and reproducible technique for evaluation of CCT.

Adult↗