PubMed Health⌕ Search

Biomedical subjects

Jeffrey S Henn

Publications and source records attributed to Jeffrey S Henn.

7 recordsLinked to original sources

Pars screw fixation of a hangman's fracture: technical case report.

OBJECTIVE AND IMPORTANCE: Traumatic spondylolisthesis of the axis may be treated by external immobilization or surgical fixation. CLINICAL PRESENTATION: We report the case of a 23-year-old man who sustained an Effendi Type II fracture of the axis, for which halo immobilization did not provide adequate stability. INTERVENTION: The unstable fracture was treated by placing lag screws in the pars interarticularis of C2, which reduced the fracture directly but sacrificed no normal spinal motion. The patient developed a solid fusion, and cervical alignment was normal at his 6-month follow-up examination. CONCLUSION: Although this technique has been reported previously, it is more commonly used in multilevel cervical fusions than for stand-alone repair of C2. Management options, anatomy, and technical considerations for the treatment of traumatic spondylolisthesis are reviewed.

Adult↗

Thoracoscopic placement of dual-rod instrumentation in thoracic spinal trauma.

OBJECTIVE AND IMPORTANCE: Traditionally, thoracic fractures that require anterior stabilization are treated through an open thoracotomy approach. Thoracoscopic instrumentation avoids many of the complications associated with an open thoracotomy but is technically challenging. We report the first cases of dual-rod internal fixation systems placed thoracoscopically for thoracic spinal trauma. CLINICAL PRESENTATION: Two male patients sustained midthoracic spinal trauma falling from motorcycles in separate incidents. Both injuries led to unstable spinal columns, but the patients had no neurological deficits and had minimal spinal cord compression. One patient had a complex spiral fracture from T6 to T8; the other had T7 burst and T8 compression fractures. Based on the complex morphological features of the patients' fractures, anterior internal fixation was the treatment of choice for both. The two available options for an anterior stabilization were open thoracotomy and thoracoscopic instrumentation. Because extensive decompression was unnecessary, a thoracoscopic approach was used. INTERVENTION: A dual-rod internal fixation system (Medtronic Sofamor Danek, Inc., Memphis, TN) was placed with two screws each in the T6 and T9 vertebral bodies of each patient. Thoracoscopy was used for direct visualization of the operative site with fluoroscopic guidance for screw placement. Surgery was completed without complications, and both patients did well afterward. Upright and supine x-rays demonstrated that the constructs were stable at 10 weeks and 6 months, respectively. CONCLUSION: Thoracoscopic instrumentation offers the advantages of a minimally invasive approach but is technically challenging. The characteristics of dual-rod fixation systems (small-profile components and step-wise insertion) provide the best biomechanical profile and facilitate thoracoscopic instrumentation.

Adult↗

Modifications to the orbitozygomatic approach. Technical note.

The orbitozygomatic craniotomy is one of the workhorse approaches of skull base surgery, providing wide, multidirectional access to the anterior and middle cranial fossae as well as the basilar apex. Complete removal of the orbitozygomatic bar increases the angles of exposure, decreases the working depth of the surgical field, and minimizes brain retraction. In many cases, however, only a portion of the exposure provided by the full orbitozygomatic approach is needed. Tailoring the extent of the bone resection to the specific lesion being treated can help lower approach-related morbidity while maintaining its advantages. The authors describe the technical details of the supraorbital and subtemporal modified orbitozygomatic approaches and discuss the surgical indications for their use. Modifications to the orbitozygomatic approach are an example of the ongoing adaptation of skull base procedures to general neurosurgical practice.

Brain Diseases↗

A new table-fixed retractor for anterior odontoid screw fixation: technical note.

The authors describe a unique retraction device adapted for anterior odontoid screw placement. A rigidly fixed tubular retractor system obviates the need for dissecting the longus colli muscles as well as for excessive retraction of the trachea, esophagus, and recurrent laryngeal nerve. The proper trajectory for screw placement can be determined by fine manipulation of the retractor as determined by biplanar fluoroscopy. The retractor is then rigidly fixed in position. The tubular corridor permits the odontoid screw to be placed in the usual fashion.

Adult↗

Interactive stereoscopic virtual reality: a new tool for neurosurgical education. Technical note.

The goal of this study was to develop a new method for neurosurgical education based on interactive stereoscopic virtual reality (ISVR). Interactive stereoscopic virtual reality can be used to recreate the three-dimensional (3D) experience of neurosurgical approaches much more realistically than standard educational methods. The demonstration of complex 3D relationships is unrivaled and easily combined with interactive learning and multimedia capabilities. Interactive stereoscopic virtual reality permits the accurate recreation of neurosurgical approaches through integration of several forms of stereoscopic multimedia (video, interactive anatomy, and computer-rendered animations). The content explored using ISVR is obtained through a combination of approach-based cadaver dissections, live surgical images and videos, and computer-rendered animations. These media are combined through an interactive software interface to demonstrate key aspects of a neurosurgical approach (for example, patient positioning, draping, incision, individual surgical steps, alternative steps, relevant anatomy). The ISVR platform is designed for use on a desktop personal computer with newly developed, inexpensive, platform-independent shutter glasses. Interactive stereoscopic virtual reality has been used to capture the anatomy and methods of several neurosurgical approaches. In this paper the authors report their experience with ISVR and describe its potential advantages. The success of a neurosurgical approach is contingent on the mastery of complex, 3D anatomy. A new technology for neurosurgical education, ISVR can improve understanding and speed the learning process. It is an effective tool for neurosurgical education, bridging the substantial gap between textbooks and intraoperative training.

Computer-Assisted Instruction↗

Black holes of the brain: how to reach challenging areas of the cerebrum.

Numerous techniques and tools can be used to access difficult areas of the cerebrum: skull base techniques, modern operating room equipment, and a unified team approach. Using these principles, challenging areas of the cerebrum can be approached with maximal success and minimal morbidity. These techniques are powerful tools in the armamentarium of neurosurgeons and can improve any neurosurgical approach. The basilar region remains one of the most difficult areas to approach. Despite its inherent complexity, lesions of the basilar region can be treated successfully. The far-lateral approach is used to access the lower two-fifths of the basilar region; the transcochlear approach is used to access the middle fifth of the basilar region; and the orbitozygomatic approach is used to access the upper two-fifths of the basilar region. Each approach beautifully exemplifies the principles of skull base surgery.

Brain↗