Impact of microbial diversity on rapid detection of enterohemorrhagic Escherichia coli in surface waters.

Enterohemorrhagic Escherichia coli (EHEC) are a physiologically, immunologically and genetically diverse collection of strains that pose a serious water-borne threat to human health. Consequently, immunological and PCR assays have been developed for the rapid, sensitive detection of presumptive EHEC. However, the ability of these assays to consistently detect presumptive EHEC while excluding closely related non-EHEC strains has not been documented. We conducted a 30-month monitoring study of a major metropolitan watershed. Surface water samples were analyzed using an immunological assay for E. coli O157 (the predominant strain worldwide) and a multiplex PCR assay for the virulence genes stx(1), stx(2) and eae. The mean frequency of water samples positive for the presence of E. coli O157, stx(1) or stx(2) genes, or the eae gene was 50%, 26% and 96%, respectively. Quantitative analysis of selected enriched water samples indicated that even in samples positive for E. coli O157 cells, stx(1)/stx(2) genes, and the eae gene, the concentrations were rarely comparable. Seventeen E. coli O157 strains were isolated, however, none were EHEC. These data indicate the presence of multiple strains similar to EHEC but less pathogenic. These findings have important ramifications for the rapid detection of presumptive EHEC; namely, that current immunological or PCR assays cannot reliably identify water-borne EHEC strains.

Adhesins, Bacterial↗

Detection of water-borne E. coli O157 using the integrating waveguide biosensor.

Escherichia coli O157:H7, the most common serotype of enterohemorrhagic E. coli (EHEC), is responsible for numerous food-borne and water-borne infections worldwide. An integrating waveguide biosensor is described for the detection of water-borne E. coli O157, based on a fluorescent sandwich immunoassay performed inside a glass capillary waveguide. The genomic DNA of captured E. coli O157 cells was extracted and quantitative real-time PCR subsequently performed to assess biosensor-capture efficiency. In vitro microbial growth in capillary waveguide is also documented. The biosensor allows for quantitative detection of as few as 10 cells per capillary (0.075 ml volume) and can be used in conjunction with cell amplification, PCR and microarray technologies to positively identify a pathogen.

Biosensing Techniques↗

tir- and stx-positive Escherichia coli in stream waters in a metropolitan area.

Diarrheagenic Escherichia coli, which may include the enteropathogenic E. coli and the enterohemorrhagic E. coli, are a significant cause of diarrheal disease among infants and children in both developing and developed areas. Disease outbreaks related to freshwater exposure have been documented, but the presence of these organisms in the urban aquatic environment is not well characterized. From April 2002 through April 2004 we conducted weekly surveys of streams in the metropolitan Baltimore, Md., area for the prevalence of potentially pathogenic E. coli by using PCR assays targeting the tir and stx(1) and stx(2) genes. Coliforms testing positive for the presence of the tir gene were cultured from 653 of 1,218 samples (53%), with a greater prevalence associated with urban, polluted streams than in suburban and forested watershed streams. Polluted urban streams were also more likely to test positive for the presence of one of the stx genes. Sequence analysis of the tir amplicon, as well as the entire tir gene from three isolates, indicated that the pathogenic E. coli present in the stream waters has a high degree of sequence homology with the E. coli O157:H7 serotype. Our data indicate that pathogenic E. coli are continually deposited into a variety of stream habitats and suggest that this organism may be a permanent member of the gastrointestinal microflora of humans and animals in the metropolitan Baltimore area.

Amino Acid Sequence↗

Estimation of viable Escherichia coli O157 in surface waters using enrichment in conjunction with immunological detection.

The use of a minimal lactose enrichment broth (MLB) in conjunction with immunomagnetic electrochemiluminescence detection (IM-ECL) was evaluated for the estimation of viable Escherichia coli O157 populations in surface water samples. In principle, E. coli O157 populations (C(initial E. coli O157)) can be derived from enrichment data according to the equation: C(initial E. coli O157) = C(initial coliforms) x C(final E. coli O157)/C(final coliforms)), assuming that the growth rates and lag times of water-borne E. coli O157 and collective coliforms are sufficiently comparable, or at least consistent. We have previously described a protocol for determining C(final E. coli O157) in MLB-enriched water samples. In the present study, 80% of coliforms (red/pink colonies on MacConkey Agar) grew in MLB, indicating that this provides reasonably accurate estimates of C(initial coliforms). Estimates of C(final coliforms) were determined from turbidity data. Initial E. coli O157 populations (C(initial E. coli O157)) were calculated for 33 Baltimore watershed samples giving a positive IM-ECL response. The majority of samples contained E. coli O157 concentrations of < 1 cell per 100 ml. These data indicate that E. coli O157 are present in surface water samples but at very low levels. Growth rates for MLB-enriched coliforms were highly variable (k= 0.47 +/- 0.13 h(-1), n= 72). There was no correlation between growth rates and any measured water parameter, suggesting that coliform populations in water samples are spatially and temporally unique. Although variability in growth rates was expected to yield some low values, the fact that most E. coli O157 concentrations were < 1 suggests that other factor(s) were also responsible. Studies with E. coli O157:H7 and wild-type E. coli suggest that increased lag times due to starvation were at least partially responsible for the observed data. Based on estimates of C(initial coliforms) and k(coliforms), MLB was evaluated for sensitivity and quantitativeness. Simulated populations of E. coli O157:H7 at stationary phase varied from ca. 10(3) to 10(8) cells ml(-1) enrichment culture. Although not suitable for quantitation, MLB enrichment in conjunction with IM-ECL can detect as few as one viable water-borne E. coli O157 cell per 100 ml surface water. Experiments are in progress to evaluate alternative media for sensitivity and quantitative detection of enterohemorrhagic E. coli.

Bacteriological Techniques↗

A handheld real time thermal cycler for bacterial pathogen detection.

The handheld advanced nucleic acid analyzer (HANAA) is a portable real time thermal cycler unit that weighs under 1 kg and uses silicon and platinum-based thermalcycler units to conduct rapid heating and cooling of plastic reaction tubes. Two light emitting diodes (LED) provide greater than 1 mW of electrical power at wavelengths of 490 nm (blue) and 525 nm (green), allowing detection of the dyes FAM and JOE/TAMRA. Results are displayed in real time as bar graphs, and up to three, 4-sample assays can be run on the charge of the 12 V portable battery pack. The HANAA was evaluated for detection of defined Escherichia coli strains, and wild-type colonies isolated from stream water, using PCR for the lac Z and Tir genes. PCR reactions using SYBR Green dye allowed detection of E. coli ATCC 11775 and E. coli O157:H7 cells in under 30 min of assay time; however, background fluorescence associated with dye binding to nonspecific PCR products was present. DNA extracted from three isolates of Bacillus anthracis Ames, linked to a bioterrorism incident in Washington DC in October 2001, were also successfully tested on the HANAA using primers for the vrrA and capA genes. Positive results were observed at 32 and 22 min of assay time, respectively. A TaqMan probe specific to the aroQ gene of Erwinia herbicola was tested on the HANAA and when 500 cells were used as template, positive results were observed after only 7 min of assay time. Background fluorescence associated with the use of the probe was negligible. The HANAA is unique in offering real time PCR in a handheld format suitable for field use; a commercial version of the instrument, offering six reaction chambers, is available as of Fall 2002.

Bacillus anthracis↗

Evaluation of parameters affecting quantitative detection of Escherichia coli O157 in enriched water samples using immunomagnetic electrochemiluminescence.

We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were </=10% in the presence of ca. 10(8) K. pneumoniae, K. oxytoca, or E. cloacae cells. None of these strains gave a positive IM-ECL signal. Although competitive binding decreased sensitivity, there still was a linear correlation between ECL signal and higher E. coli O157:H7 cell concentrations. These studies indicate that IM-ECL in conjunction with MLB enrichment is capable of quantitatively detecting as few as 10(3) to 10(5) E. coli O157:H7 cells ml(-1), depending on percent recoveries, in enriched samples that contain ca. 10(9) total lactose-fermenting bacteria ml(-1). Assuming comparable growth rates for E. coli O157:H7 and other lactose-fermenting bacteria in MLB, it may be possible to detect as few as one E. coli O157:H7 in 100 ml of raw water containing as many as 10(4) to 10(6) lactose-fermenting bacteria (i.e., total coliforms).

Escherichia coli O157↗

A field investigation of Bacillus anthracis contamination of U.S. Department of Agriculture and other Washington, D.C., buildings during the anthrax attack of October 2001.

In response to a bioterrorism attack in the Washington, D.C., area in October 2001, a mobile laboratory (ML) was set up in the city to conduct rapid molecular tests on environmental samples for the presence of Bacillus anthracis spores and to route samples for further culture analysis. The ML contained class I laminar-flow hoods, a portable autoclave, two portable real-time PCR devices (Ruggedized Advanced Pathogen Identification Device [RAPID]), and miscellaneous supplies and equipment to process samples. Envelopes and swab and air samples collected from 30 locations in the metropolitan area once every three days were subjected to visual examination and DNA extraction, followed by real-time PCR using freeze-dried, fluorescent-probe-based reagents. Surface swabs and air samples were also cultured for B. anthracis at the National Veterinary Service Laboratory (NVSL) in Ames, Iowa. From 24 October 2001 to 15 September 2002, 2,092 pieces of mail were examined, 405 real-time PCR assays were performed (comprising 4,639 samples), and at the NVSL 6,275 samples were subjected to over 18,000 platings. None of the PCR assays on DNA extracted from swab and air samples were positive, but viable spores were cultured from surface swabs taken from six locations in the metropolitan area in October, November, and December 2001 and February, March, and May 2002. DNA extracted from these suspected B. anthracis colonies was positive by real-time and conventional PCRs for the lethal factor, pXO1, and for capA and vrr genes; sequence analysis of the latter amplicons indicated >99% homology with the Ames, vollum, B6273-93, C93022281, and W-21 strains of B. anthracis, suggesting they arose from cross-contamination during the attack through the mail. The RAPID-based PCR analysis provided fast confirmation of suspect colonies from an overnight incubation on agar plates.

Anthrax↗

Persistence of Escherichia coli O157:H7 in soil and on plant roots.

Soil microcosms were inoculated with Escherichia coli O157:H7 to test persistence in fallow soil, on roots of cover crops and in presence of manure. In fallow soils, E. coli O157:H7 persisted for 25-41 days, on rye roots for 47-96 days and on alfalfa roots, in a silt loam soil, for 92 days whereas on other legumes persistence ranged from 25-40 days, similar to fallow soil. Manure did not seem to affect the persistence of E. coli O157:H7 in these soils. Indigenous and manure-applied coliform populations often decreased faster when E. coli O157:H7 was applied, indicating possible competition between microflora. Coliform populations in microcosms not inoculated with E. coli O157:H7 decreased more slowly or increased. Microbial community analyses showed little effect for E. coli O157:H7 inoculation or addition of manure. Microbial community metabolic activity was enhanced from rye roots after 14 days and by 63 days from alfalfa roots. Microbial community lactose utilization increased over time on rye roots in all soils and on alfalfa roots in a silt loam soil when E. coli O157:H7 was inoculated. Lactose utilization also increased for uninoculated rye roots, soil around rye roots and in some fallow soils. Our data suggest that clay increases persistence and activity of E. coli O157:H7 and other coliforms. In frozen soil stored for over 500 days, E. coli O157:H7 was viable in 37% of tested samples. In summary, E. coli O157:H7 persisted longer and activity was enhanced with some cover crops in these soils due to plant roots, the presence of clay and freezing.

Aluminum Silicates↗