PubMed Health⌕ Search

Biomedical subjects

Jenny Emnéus

Publications and source records attributed to Jenny Emnéus.

13 recordsLinked to original sources

Evaluation of progesterone content in saliva using magnetic particle-based immuno supported liquid membrane assay (m-ISLMA).

Progesterone in saliva was monitored using a new method called magnetic particle-based immuno supported liquid membrane assay (m-ISLMA) in a sequential injection (SI) setup, allowing automatic sample cleanup, analyte enrichment, and detection in a single analysis unit. Progesterone (Ag) diffuses from a continuous flowing sample - the donor - into a supported organic liquid membrane (SLM), based on analyte partitioning (solubility) between the aqueous donor and the organic phase. The Ag is re-extracted from the SLM into a second stagnant aqueous acceptor, containing antibodies (Ab) immobilized on magnetic beads, held at the bottom of the acceptor by a magnet. Due to the formation of strong Ag-Ab-bead complexes and a large excess of Ab-beads, the Ag is accumulated and selectively enriched in the acceptor. The extracted progesterone was quantified by injecting into the acceptor a horseradish peroxidase (HRP) labeled analyte tracer, the substrate (luminol, H(2)O(2), and p-iodophenol), and finally detection of the generated chemiluminescence by a photomultiplier tube. After optimization of experimental parameters (e.g., sample flow rate, extraction time, type of organic solvent and antibody-bead concentration in the acceptor), a detection limit of 8.50+/-0.17 fgL(-1) and a dynamic range between 35 fgL(-1) and 10 pgL(-1) was reached. The progesterone level of saliva for three subjects (women in different period of ovarian cycle) was investigated, and the corresponding progesterone concentrations detected with m-ISLMA coincided well with the expected values.

Adult↗

Ultrasensitive magnetic particle-based immunosupported liquid membrane assay.

A magnetic particle-based immuno-supported liquid membrane assay (m-ISLMA) based on chemiluminescence detection of a horseradish peroxidase-labeled hapten tracer that allows sample cleanup, analyte enrichment, and detection in a single analysis unit has been developed. Antibodies were immobilized on magnetic beads, and their position in the acceptor was controlled by two alternating opposing electromagnetic fields generated by a voltage applied to either of two electromagnets placed below and above the acceptor channel of the supported liquid membrane unit. The influence of antibody bead dilution in the acceptor was investigated and found to follow the ISLM theory, that is improved enrichment and sensitivity with increasing antibody concentration. Two different extraction procedures were investigated: procedure 1 (m-ISLMA-P1), which keeps the antibody beads trapped at the bottom of the acceptor during the entire analysis process; and procedure 2 (m-ISLMA-P2), which keeps the antibody beads dispersed and in motion in the acceptor phase during the extraction process. m-ISLMA-P2 resulted in 2000 times improved enrichment of simazine and a more than 3 orders of magnitude better limit of detection (LOD(10%)) (1.29 x 10(-5) microg L(-1)) than for m-ISLMA-P1 (2.00 x 10(-2) microg L(-1)) and corresponding microtiter plate magnetic particle-based ELISA (m-ELISA, LOD(10%) 1.30 x 10(-1) microg L(-1)). m-ISLMA-P2 and m-ELISA were further applied for the extraction and analysis of simazine-spiked surface water and fruit juice, finding no evidence for matrix influence for the former method; however, indications that trace amounts (nanograms per liter) of simazine or specific cross-reactants were present in both samples.

Adsorption↗

Chemometric exploration of an amperometric biosensor array for fast determination of wastewater quality.

Four wastewater samples of different treatment qualities; untreated, alarm, alert and normal, from a Swedish chemi-thermo-mechanical pulp mill and pure water were investigated using an amperometric bio-electronic tongue in a batch cell. The aim was to explore enzymatically modified screen-printed amperometric sensors for the discrimination of wastewater quality and to counteract the inherent drift. Seven out of eight platinum electrodes on the array were modified with four different enzymes; tyrosinase, horseradish peroxidase, acetyl cholinesterase and butyryl cholinesterase. At a constant potential the current intensity on each sensor was measured for 200s, 100s before injection and 100s after injection of the sample. The dynamic biosensor response curves from the eight sensors were used for principal component analysis (PCA). A simple baseline and sensitivity correction equivalent to multiplicative drift correction (MDC), using steady state intensities of reference sample (catechol) recordings, was employed. A clear pattern emerged in perfect agreement with prior knowledge of the samples explaining 97% of the variation in the data by two principal components (PCs). The first PC described the treatment quality of the samples and the second PC described the difference between treated and untreated samples. Horseradish peroxidase and pure platinum sensors were found to be the determinant sensors, while the rest did not contribute much to the discrimination. The wastewater samples were characterized by the chemical oxygen demand (COD), biological oxygen demand (BOD), total organic carbon (TOC), inhibition of nitrification, inhibition of respiration and toxicity towards Vibrio fischeri using Microtox, the freshwater alga Pseudokirchneriella subcapita and the freshwater crustacean Daphnia magna.

Algorithms↗

A micro-immuno supported liquid membrane assay (mu-ISLMA).

A chemiluminescent (CL) based micro-immuno supported liquid membrane assay (mu-ISLMA) has been developed that enables clean up, enrichment and detection of simazine in a single miniaturised cartridge system. The mu-ISLM cartridge contains a supported liquid membrane (SLM) sandwiched between a donor and an acceptor plate (channel volumes 1.65 microL), the latter being covered by a thin layer of gold on to which anti-simazine antibodies were covalently immobilised via a self assembled monolayer (SAM) of either dithiobis(11-aminoundecane, hydrochloride) (DTAU) or beta-mercaptoethylamine (beta-MEA). The mu-ISLMA based on DTAU was characterised by both a high apparent extraction efficiency (E(app) = 136%) and high apparent enrichment factor (E(e)(app) = 544), which resulted in a very high sensitivity for simazine (LOD = 0.1 ng L(-1)). The paper discusses the influence of the different SAMs and three different anti-simazine-antibody preparations (polyclonal, affinity purified polyclonal and monoclonal) on the extraction parameters and assay sensitivity. The influence of the sample matrix (e.g. mineral water, orange juice and milk) on the simazine mu-ISLMA was also investigated.

Biosensing Techniques↗

Multivariate analysis to separate the signal given by cross-reactants in immunoassay with sample matrix dilution.

This paper describes a new approach to achieve selectivity in an immunoassay by separating the signals given by two cross-reactive compounds present simultaneously in a complex sample matrix. The method is based on the sequential dilution of the sample containing a mixture of the two analytes, spiking each diluted sample with a reference compound, and the detection by enzyme-linked immunosorbent assay (ELISA). The obtained multivariate response was used for the individual calibrations of the assay for each of the two cross-reactants simultaneously by using principal component analysis (PCA) and partial least squares regression (PLSR) data modeling. The calibration models showed that the signal separation due the analytes 2,4-dinitrophenol (2,4-DNP) and 4-nitrophenol (4-NP) was possible with a prediction concentration error of 1.4 microM and 72 microM, respectively.

2,4-Dinitrophenol↗

Microfluidic biosensing systems. Part I. Development and optimisation of enzymatic chemiluminescent micro-biosensors based on silicon microchips.

Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (micro-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the micro-biosensors in a microfluidic sequential injection analysis (microSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the microSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 2(3)-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 microM luminol and 150 microM PIP at a flow rate of 18 microl min(-1), the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both micro-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP micro-biosensors responded linear in a log-log format within the range 10-1000 microM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP micro-biosensors responded linear (log-log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2-3 days.

Biosensing Techniques↗

Developments toward a microfluidic system for long-term monitoring of dynamic cellular events in immobilized human cells.

A microfluidic system for long-term real-time monitoring of dynamic cellular events of immobilized human cells was investigated. The luciferase reporter gene activity in the reporter cell line HFF11, based on HeLa cells, was used as the model system. The cells were immobilized on silicon flow-through microchips and continuously supplied with a cell medium at 2 microL/min while maintaining the chip at 37 degrees C. The HFF11 cell line was designed for high-throughput screening of ligands for seven-transmembrane receptors. When a ligand binds, the receptor is activated and a cascade of intracellular reactions starts, ending with the synthesis of the reporter protein Photinus luciferase. The major goal was to develop a microfluidic system for continuous long-term assaying of the intracellular reporter gene activity in real time and determine the conditions, which could minimize cells stress and hence unspecific expression of the reporter gene. In the resulting microfluidic system and assay protocol, the cell microchip could be kept and assayed for a period up to 30 h. The developed system and data outcome was compared with a corresponding microtiter plate performed with the same cell line to highlight the advantages obtained in the microfluidic format.

Animals↗

A chemiluminescence flow immunosensor based on a porous monolithic metacrylate and polyethylene composite disc modified with protein G.

A generic, fast, sensitive and new type of flow immunosensor has been developed. The basis is a monolithic porous poly(glycidyl methacrylate-co-trimethylolpropane trimethacrylate) polymer disc modified with protein G, placed in a fountain type flow cell compartment, in close proximity to a photomultiplier tube (PMT). Analyte and HRP labelled analyte derivative (tracer) compete for anti-analyte antibody binding sites. The mixture is then injected into the flow immunosensor system where the formed analyte- and tracer-antibody complexes are trapped by the monolithic protein G disc. The amount of bound tracer, inversely related to the concentration of analyte in the sample, is determined in a second step by injection of luminol, p-iodophenol and H2O2, generating enhanced chemiluminescence (CL) with horseradish peroxidase (HRP). A third and final step is need for regeneration of the protein G disc so that a new analysis cycle can take place. The performance of the disc immunosensor system was compared with a one step continuous flow injection immunoassay (FIIA) system, using the same reagents and a protein G column, in terms of assay sensitivity and influence of matrix effects from various water samples (millipore-, tap- and surface water). The detection limit for the analyte atrazine in PBS and surface water (SW) was 0.208 +/- 0.004 microg l(-1) (PBS) and 0.59 +/- 0.120 microg l(-1) (SW) for the FIIA and 0.033 +/- 0.003 microg l(-1) (PBS) and 0.038+/-0.003 microg l(-1) (SW) for the disc immunosensor. Statistical comparison of the two systems shows that the disc immunosensor results were significantly less influenced by the sample matrix, which is explained by the fact that the sample in the FIIA arrives simultaneously with the matrix to the detector, whereas these are separated in time in the disc immunosensor system.

Adsorption↗

Immuno-SLM-a combined sample handling and analytical technique.

Immuno-supported liquid membrane (immuno-SLM) extraction is a new technique that makes use of antibody (Ab)-antigen interactions as the "extraction force" to drive the mass transfer in a selective way. In immuno-SLM, anti-analyte (Ag) Abs are introduced into the acceptor phase of the SLM unit to trap the Ag that passes from the flowing donor through the SLM into the stagnant acceptor. The amount of immuno-extracted analyte (AbAg) is quantified by connecting the immuno-SLM unit on-line with a non-competitive heterogeneous fluorescence flow immunoassay (FFIA) that makes use of a fluorescein-labeled analyte tracer that titrates the residual excess of Ab present in the acceptor. A restricted access (RA) column is used for the separation of the two tracer fractions (Ag* and AbAg*) formed, and the eluted AbAg* fraction is measured downstream by a fluorescence detector. Factors influencing the optimum immuno-SLM extraction parameters, i.e., donor flow rate, extraction time and type of Ab, were investigated for immuno extraction of the model analyte atrazine. Immuno-SLM coupled to FFIA (immuno-SLM-FFIA) and FFIA alone were compared in terms of the assay sensitivities obtained and the sample matrix influence. The concentration at the mid-point of the calibration curve (IC(50)) was 16.0+/-1.4 and 36+/-16 microg/l, the limit of detection (LOD) was 2.0+/-1.1 and 20+/-10 microg/l, and the dynamic range was 2-100 and 20-500 microg/l atrazine for immuno-SLM-FFIA and FFIA, respectively. The matrix influence on the FFIA was significant in orange juice and surface water, whereas the influence was minor for immuno-SLM-FFIA with recoveries between 104% and 115% for 5 microg/l atrazine in tap water, orange juice and river water.

Antibodies↗

Microfluidic enzyme immunosensors with immobilised protein A and G using chemiluminescence detection.

Affinity proteins were covalently immobilised on silicon microchips with overall dimensions of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235 microm depth and 25 microm width, and used to develop microfluidic immunosensors based on horseradish peroxidase (HRP), catalysing the chemiluminescent oxidation of luminol/p-iodophenol (PIP). Different hydrophilic polymers with long flexible chains (polyethylenimine (PEI), dextran (DEX), polyvinyl alcohol, aminodextran) and 3-aminopropyltriethoxysilane (APTS) were employed for modification of the silica surfaces followed by attachment of protein A or G. The resulting immunosensors were compared in an affinity capture assay format, where the competition between the labelled antigen and the analyte for antibody-binding sites took place in the bulk of the solution. The formed immunocomplexes were then trapped by the microchip affinity capture support and the amount of bound tracer was monitored by injection of luminol, PIP and H2O2. All immunosensors were capable of detecting atrazine at the sub-microg l(-1) level. The most sensitive assays were obtained with PEI and DEX polymer modified supports and immobilised protein G, with limits of detection of 0.006 and 0.010 microg l(-1), and IC50 values of 0.096 and 0.130 microg l(-1), respectively. The protein G based immunosensors were regenerated with 0.4 M glycine-HCl buffer pH 2.2, with no loss of activity observed for a storage and operating period of over 8 months. To estimate the applicability of the immunosensors to the analysis of real samples, PEI and DEX based protein G microchips were used to detect atrazine in surface water and fruit juice, spiked with known amounts of the atrazine, giving recovery values of 87-102 and 88-124% at atrazine fortification levels of 0.5-3 and 80-240 microg l(-1), respectively.

Adsorption↗

A capillary-based amperometric flow immunoassay for 2,4,6-trichlorophenol.

This paper describes the development of two different capillary-based heterogeneous competitive flow immunoassay formats (capillary flow injection immunoassay (CFIIA) and capillary sequential injection immunoassay (CSIIA)) for the determination of 2,4,6-trichlorophenol (2,4,6-TCP). The assays are based on the competition between the analyte and an analyte derivative labelled with the enzyme beta-galactosidase, for an anti-TCP antibody, followed by the injection of the mixture at equilibrium into a flow stream, where separation between the fractions bound and unbound to the antibody is performed in a glass capillary containing immobilised protein A. The antibody-tracer fraction retained inside the protein A capillary was measured by injection of 4-aminophenyl- beta- D-galactoside (4-APG), followed by amperometric detection of the enzymatically generated 4-aminophenol (4-AP), leading to a negative correlation between the signal and the analyte concentration. The two immunoassay formats were compared in terms of sensitivity and speed, giving IC(50) values of 1.41+/-0.03 and 1.64+/-0.07 micro g L(-1), detection limits of 0.2 and 0.4 micro g L(-1), and sample throughputs of 6 and 4 h(-1) for the CFIIA and CSIIA system, respectively. The influence of different interfering chlorophenolic compounds in the assay was minor, with only one exception (i.e. 2,4-dichlorophenol). In addition, different water matrices were tested (surface, tap, and rain water), showing that the matrix influence was negligible, except for rainwater, which resulted in a 30% increase in sensitivity. As a conclusion, the assay is suitable for the fast screening of TCP present at low concentration levels in water samples.

Antibodies, Monoclonal↗

Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection.

Silicon microchips with immobilized antibodies were used to develop microfluidic enzyme immunoassays using chemiluminescence detection and horseradish peroxidase (HRP) as the enzyme label. Polyclonal anti-atrazine antibodies were coupled to the silicon microchip surface with an overall dimension of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235-microm depth and 25-microm width. Different immobilization protocols based on covalent or noncovalent modification of the silica surface with 3-aminopropyltriethoxysilane (APTES) or 3-glycidoxypropyltrimethoxysilane (GOPS), linear polyethylenimine (LPEI, MW 750,000), or branched polyethylenimine (BPEI, MW 25,000), followed by adsorption or covalent attachment of the antibody, were evaluated to reach the best reusability, stability, and sensitivity of the microfluidic enzyme immunoassay (microFEIA). Adsorption of antibodies on a LPEI-modified silica surface and covalent attachment to physically adsorbed BPEI lead to unstable antibody coatings. Covalent coupling of antibodies via glutaraldehyde (GA) to three different functionalized silica surfaces (APTES-GA, LPEI-GA, and GOPS-BPEI-GA) resulted in antibody coatings that could be completely regenerated using 0.4 M glycine/HCl, pH 2.2. The buffer composition was shown to have a dramatic effect on the assay stability, where the commonly used phosphate buffer saline was proved to be the least suitable choice. The best long-term stability was obtained for the LPEI-GA surface with no loss of antibody activity during one month. The detection limits in the microFEIA for the three different immuno surfaces were 45, 3.8, and 0.80 ng/L (209, 17.7, and 3.7 pM) for APTES-GA, LPEI-GA, and GOPS-BPEI-GA, respectively.

Antibodies↗

A glucose dehydrogenase biosensor as an additional signal amplification step in an enzyme-flow immunoassay.

Both the antibody affinity and the detectability of the label are essential in deciding the final characteristics of a heterogeneous immunoassay. This paper describes an approach to obtain a supplementary enhancement of the signal generated by using an enzyme label, e.g., by including the product of the enzymatic reaction in an additional amplification cycle during the detection step performed with an amperometric biosensor based on glucose dehydrogenase (GDH). An immunoassay format with a labelled analyte derivative that competes with the analyte present in the sample for a limited amount of antibody binding sites was employed. The beta-galactosidase label hydrolyses the substrate aminophenyl-beta-galactopyranoside, and the generated aminophenol enters then into a bioelectrocatalytic amplification cycle at the GDH biosensor. The principle was applied for determination of 4-nitrophenol, with the best minimal concentration of 1.5 microM and a midpoint of the calibration of 24 microM. The potentials and limitations of such a system are discussed.

Biosensing Techniques↗