Jens Bühren

Publications and source records attributed to Jens Bühren.

At least 19 recordsLinked to original sources

Intraindividual comparison of higher-order aberrations after implantation of aspherical and spherical intraocular lenses as a function of pupil diameter.

PURPOSE: To compare intraindividual higher-order wavefront aberrations after implantation of aspherical and spherical intraocular lenses (IOLs) as function of pupil diameter. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: In this prospective study, wavefront measurements of 21 patients after implantation of a spherical IOL (AMO AR40e) in 1 eye and an aspherical IOL (AMO Tecnis) in the contralateral eye were analyzed. Third-, 4th-, 5th-, total higher-order aberration (HOA) root-mean-square (RMS), and primary spherical aberration (Z(4)(0)) were compared at different virtual pupil diameters of 3 to 6 mm. RESULTS: For both IOLs and each higher order analyzed, values increased with increasing pupil diameter. Fourth-order RMS and Z(4)(0) in the aspherical IOL group were significantly lower than with the spherical IOL at all analyzed pupil diameters. The total HOA RMS of the aspherical IOL was significantly lower than the spherical IOL only at 6 mm pupil diameter. For 3rd- and 5th-order RMS, no significant difference was found between the tested IOLs at any pupil diameter. CONCLUSION: In comparison to a spherical IOL, the aspherical Tecnis IOL reduced Z(4)(0) and 4th-order RMS significantly for pupil diameters of 3 to 6 mm, whereas total HOA RMS was only significantly reduced for a pupil diameter of 6 mm.

Aged↗

Factors affecting the change in lower-order and higher-order aberrations after wavefront-guided laser in situ keratomileusis for myopia with the Zyoptix 3.1 system.

PURPOSE: To identify factors that affect the change in lower- and higher-order wavefront aberrations after myopic wavefront-guided laser in situ keratomileusis (wg-LASIK). SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Sixty myopic eyes of 32 patients were treated with wg-LASIK (Zyoptix version 3.1, Bausch & Lomb) and had an uneventful follow-up of 12 months. Wavefront errors were measured preoperatively and 12 months after LASIK and were computed for pupil diameters (PDs) of 3.5 mm and 6.0 mm. Multiple stepwise regression analysis was performed to assess the influence of patient age, spherical equivalent (SE), sphere, cylinder, optical zone (OZ) diameter, and the preoperative individual Zernike coefficients on lower- and higher-order aberration (HOA) change. RESULTS: The mean preoperative SE was -5.59 diopters (D) +/- 2.20 (SD) (range -1.00 to -9.50 D); the mean OZ diameter was 6.70 +/- 0.68 mm (range 5.6 to 8.1 mm). Reduction in almost all Zernike coefficients was influenced significantly by the preoperative amount of the individual coefficient. The effect varied among the coefficients and was lower with the 6.0 mm PD. With the 3.5 mm PD, age, SE, sphere, cylinder, and OZ diameter did not have a significant effect on individual Zernike coefficients. With the 6.0 mm PD, SE and OZ diameter had a significant effect on the induction of Z4(0); the OZ diameter also had an effect on the induction of coma root mean square. CONCLUSIONS: Three groups of factors influenced the change in HOAs: The negative correlation with the magnitude of preoperative HOA values reflected the effect of the wavefront-guided algorithm. The SE and OZ diameter affected the inadvertent induction of spherical aberrations. Randomly acting effects such as decentration or flap creation, which were not included in the model, affected the induction of HOAs, particularly coma-like terms.

Adult↗

Visual performance of aspherical and spherical intraocular lenses: intraindividual comparison of visual acuity, contrast sensitivity, and higher-order aberrations.

PURPOSE: To intraindividually compare visual performance in terms of photopic high-contrast visual acuity (HCVA), mesopic HCVA, mesopic low-contrast visual acuity (LCVA), and contrast sensitivity (CS) in patients after implantation of either an aspherical or a spherical intraocular lens (IOL). SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Forty eyes of 20 patients were randomized to implantation of an aspherical IOL (Tecnis Z9000, AMO) in 1 eye and a spherical IOL (Sensar AR40e, AMO) in the other eye. Three to 4 months postoperatively, photopic HCVA (270 cd/m(2)) was measured with the observer-independent Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS) and high-mesopic HCVA and LCVA (8 cd/m(2)) were measured with Early Treatment Diabetic Retinopathy Study charts. CS was assessed with the FF-CATS under photopic (167 cd/m(2)), high-mesopic (1.67 cd/m(2)), and low-mesopic (0.167 cd/m(2)) luminance conditions with and without glare. For each individual eye, higher-order wavefront aberrations were reconstructed for a physiological mesopic pupil diameter. Intraindividual differences (Delta(i)) in visual acuity, contrast sensitivity, and higher-order aberrations (HOAs) were calculated, and the influence of age and Delta(i) HOA on Delta(i) contrast sensitivity (logCS) under high-mesopic conditions was investigated using multiple regression analysis. RESULTS: There were no statistically significant differences between the Tecnis IOL and the Sensar IOL in visual acuity measurements or contrast sensitivity measurements. For physiological mesopic pupil diameter, primary spherical aberration (Z(4)(0)) was significantly lower in the Tecnis group (P<.001). For all parameters studied except Z(4)(0), the Delta(i) values were distributed around zero. Multiple regression analysis showed only a partial influence of Delta(i) Z(4)(0) on Delta(i) logCS (adjusted R(2) = 0.49) but did not show any influence of age, coma-like aberration, or residual HOA. CONCLUSIONS: Although Z(4)(0) was significantly lower in the eyes with the aspherical IOL, no statistically significant differences were found between aspherical and spherical IOLs in LCVA, HCVA, and contrast sensitivity. Statistical analysis of intraindividual contrast sensitivity differences showed that in most patients, this Z(4)(0) difference was too low to have an effect on contrast sensitivity.

Aged↗

Correlation between clinical in vivo confocal microscopic and ex vivo histopathologic findings of Salzmann nodular degeneration.

PURPOSE: To report clinical, in vivo confocal microscopy and ex vivo histopathologic findings of Salzmann nodular degeneration (SND). METHODS: A 48-year-old woman with symptoms of ocular irritation and decreased visual acuity caused by SND in both eyes was treated by corneal scraping and phototherapeutic keratectomy (PTK). Slit-lamp biomicroscopy, in vivo confocal microscopy, ex vivo light microscopy, immunohistology, and corneal topography were performed. RESULTS: In vivo confocal microscopy showed an irregular network of highly reflective structures representing activated keratocytes, which could be seen by light microscopy and characterized immunohistologically as myofibroblasts. Unstructured areas with increased reflectivity correlated with irregularly arranged collagen fibers and hyaline deposits in the nodulus. Epithelial cells in vivo appeared atypically shaped and elongated. These observations were consistent with decreased thickness of the epithelium over the nodules showed by histopathology. Treatment led to a dramatic reduction of hyperopia. Two months after surgery, uncorrected visual acuity (UCVA) in the right eye was 20/32 and 20/20 with a refraction of -0.75 -0.75/0 degrees. UCVA in the left eye was 20/40 and 20/20 with a refraction of +0.50 -1.75/165 degrees. Corneal topography showed regular astigmatism. CONCLUSION: In vivo confocal microscopy confirmed the clinicopathologic findings of Salzmann's nodular degeneration. Observations by in vivo confocal microscopy were consistent with the histopathologic descriptions of SND.

Actins↗

Measuring contrast sensitivity under different lighting conditions: comparison of three tests.

PURPOSE: The purpose of this study was to evaluate three psychophysical tests for the measurement of contrast sensitivity (CS) and disability glare (DG) at different luminance levels. METHODS: In 60 eyes of 60 individuals (group 1: 20 healthy eyes of young individuals; group 2: 20 healthy eyes of elderly subjects; group 3: 20 eyes with nuclear cataract), CS with best correction was measured twice with the Frankfurt-Freiburg Contrast and Acuity Test System (FF-CATS) and the Functional Acuity Contrast Test (FACT, 1.5 cycles per degree [cpd]) at 167 cd/m2 and 0.167 cd/m2, and with the Pelli-Robson Chart (PRC) at 100 cd/m2 with and without glare. Repeatability of test and retest, and discriminative ability between the different subgroups, were assessed for CS values. RESULTS: Maximum CS values varied across tests. In all groups, highest CS values were obtained with the photopic FF-CATS. For FACT scores at 1.5 cpd, there was a ceiling effect for young subjects. CS scores obtained with the PRC were the lowest. The PRC had the best test-retest repeatability of all tests. Under mesopic conditions with glare, reliability was generally lower; the FF-CATS had the highest repeatability of the mesopic tests. The FF-CATS discriminated best between the different groups for all conditions. CONCLUSIONS: There are large discrepancies in the test results between CS testing methods, especially under different lighting conditions. Results from different CS tests are not interchangeable.

Adult↗

A standardized drawing scheme to document corneal changes following refractive corneal surgery.

PURPOSE: To present a systematic and standardized drawing scheme for unambiguous and reproducible documentation of corneal changes after incisional techniques, coagulative procedures, and lamellar and surface ablation excimer surgery. METHODS: Standardized symbols in five colors representing specific corneal conditions after incisional surgery (eg, radial keratotomy, astigmatic keratotomy), coagulative procedures (eg, laser thermokeratoplasty, conductive keratoplasty), surface ablation (eg, photorefractive keratectomy, laser subepithelial keratomileusis, epi-LASIK), and LASIK are used to record corneal changes in frontal and sectional views. RESULTS: Corneal changes following refractive corneal surgery were documented. CONCLUSIONS: The drawing scheme permits specific features to be followed in the clinic in a clear and unambiguous manner.

Cornea↗

Corneal first-surface aberration analysis of the biomechanical effects of astigmatic keratotomy and a microkeratome cut after penetrating keratoplasty.

Astigmatic keratotomy (AK) was performed in a patient after penetrating keratoplasty (PKP) for keratoconus to reduce high post-PKP astigmatism. The procedure led to a significant decrease in astigmatism, but corneal higher-order aberrations (HOAs) increased. After PKP, the patient was scheduled for 2-step laser in situ keratomileusis (LASIK) to correct myopia and astigmatism. One day after the microkeratome cut, a decrease of -2.75 diopters in the spherical equivalent (SE) was noted. Although subjective manifest cylinder and corneal spherical aberrations were marginally affected, a marked decrease in coma and other HOAs could be observed. One month after the cut, the SE was unchanged. Excimer laser ablation was not performed as the patient was satisfied with the result and refused further treatment. This case shows that AK cuts can induce HOAs and a single microkeratome cut performed in corneal grafts can have strong biomechanical effects on lower-order aberrations and HOAs. If LASIK is planned after PKP, a 2-step approach is recommended to anticipate biomechanical effects and avoid overcorrection or undercorrection.

Adult↗

Intermittent myopic shift of 4.0 diopters after implantation of an Artisan iris-supported phakic intraocular lens.

A 45-year-old man with bilateral high myopia and myopic astigmatism had uneventful implantation of a -10.5 diopters (D) Artisan iris-fixated anterior chamber phakic intraocular lens (PIOL) (Ophtec) in both eyes. In the first days after surgery, uncorrected visual acuity (UCVA) was 20/16 in the right eye and 20/16 in the left; the position of the PIOL was stable. Ten days after surgery, the left eye developed a myopic shift of 4.0 D. Further examination showed that the myopia disappeared when the pupil was medically dilated. After the pupil returned to a natural position, the myopic shift reappeared. Because there were no changes in the subsequent 4 months, we decided to exclavate the IOL, rotate it by 10 degrees, and reenclavate it with less tissue. The myopic shift did not return over the following 20 months, and the UCVA was 20/20. In rare cases, iris-fixated anterior chamber IOLs may induce refractive changes related to effects on the surrounding anatomic structures. This may be corrected by phakic IOL rotation or reenclavation of the phakic IOL with less tissue.

Astigmatism↗

Influence of pupil and optical zone diameter on higher-order aberrations after wavefront-guided myopic LASIK.

PURPOSE: To investigate the influence of pupil and optical zone (OZ) diameter on higher-order aberrations (HOAs) after myopic wavefront-guided laser in situ keratomileusis (LASIK). METHODS: Twenty-seven myopic eyes of 19 patients were included. The mean preoperative spherical equivalent was -6.86 diopters (D) +/- 1.24 (SD) (range -4.25 to -9.5 D); the mean planned OZ diameter was 6.26 +/- 0.45 mm (range 5.7 to 7.1 mm). All patients had uneventful wavefront-guided LASIK (Zyoptix version 3.1, Bausch & Lomb) and an uncomplicated follow-up of 12 months. Wavefront measurements were performed with a Hartmann-Shack sensor in maximum mydriasis preoperatively and 12 months after LASIK. Wavefront errors were computed for pupil diameters (PDs) of 3.0, 3.5, 4.0, 5.0, 6.0, and 7.0 mm for the individual OZ diameter and for the individual mydriatic PD (7.93 +/- 0.46 mm). The impact of the relationship between pupil diameter and OZ diameter (fractional clearance [FC]) on HOA was described and quantified using curvilinear regression with a 4th-order polynomial fit. RESULTS: There was a reproducible relationship between FC and the amount of induced HOA. The change in HOA root mean square and primary spherical aberration (Z(4)0) was significantly correlated with FC. If the OZ was 16.5% larger than the pupil (FC = 1.17), only half the amount of HOA was expected to be induced than if the OZ equaled the pupil. In contrast, an OZ that was 9% smaller than the pupil (FC = 0.91) resulted in an HOA induction 50% higher than at FC = 1. CONCLUSION: The OZ zone to pupil ratio (fractional clearance) had a significant impact on HOA induction after wavefront-guided LASIK.

Adult↗

Comparison of corneal higher-order aberrations induced by myopic and hyperopic LASIK.

OBJECTIVE: To compare the change in anterior corneal higher-order (third- to fifth-order) aberrations (HOAs) induced by myopic and hyperopic LASIK. DESIGN: Retrospective comparative case series. PARTICIPANTS: One hundred eyes (50 myopes and 50 hyperopes) of 59 patients were included. The mean preoperative spherical equivalent (SE) was -4.22+/-1.78 diopters (D; range, -1.25 to -8.00 D) in the myopic group (group A) and +2.72+/-1.25 D (range, +0.25 to +5.00 D) in the hyperopic group (group B). INTERVENTION: LASIK was performed using a conventional spherocylindrical laser algorithm (Planoscan V2.9992, Bausch & Lomb/Technolas, Munich, Germany). Optical zone diameter was 6.70+/-0.32 mm (range, 6-7 mm) in group A and 6.59+/-0.19 mm (range, 6.5 to 7 mm) in group B. Third to fifth corneal HOA were computed for a pupil diameter of 6 mm from corneal topographic examinations before and 1 month after surgery. MAIN OUTCOME MEASURES: Change in corneal HOAs, derived from corneal topography. RESULTS: Total HOA root mean square (RMS) changed in group A by 0.167+/-0.180 microm (factor 1.53) and in group B by 0.341+/-0.341 microm (factor 1.89). The mean induction of coma RMS was significantly different in both groups (myopes, 0.092+/-0.195 microm; hyperopes, 0.252+/-0.305 microm; P<0.05). For spherical aberration (Z 4,0), the myopic group showed a significant increase (0.130+/-0.120 microm; factor 1.6; P<0.001), whereas the hyperopic group showed a significant decrease (-0.317+/-0.158 microm; factor 0.76; P<0.001). Fifth-order aberrations showed an increase in both groups, which was higher in group B (0.069+/-0.120 microm; factor 2.46) than in group A (0.005+/-0.065 microm; factor 1.49). CONCLUSIONS: Myopic and hyperopic LASIK had different patterns of HOA induction. Myopic LASIK induced positive spherical aberrations and positive secondary astigmatism, whereas hyperopic LASIK induced negative spherical aberrations and negative secondary astigmatism. Hyperopic LASIK induced more third- and fifth-order comalike aberrations than myopic LASIK.

Adult↗

Position of angle-supported, iris-fixated, and ciliary sulcus-implanted myopic phakic intraocular lenses evaluated by Scheimpflug photography.

PURPOSE: To examine postoperative positional stability of myopic phakic intraocular lenses (IOLs). DESIGN: Prospective, nonrandomized clinical study. METHODS: The study included 46 eyes which received an anterior chamber angle-supported (Bausch & Lomb NuVita; 10 eyes), anterior chamber iris-fixated (Ophtec Artisan; 20 eyes) or ciliary sulcus-implanted phakic IOL (Staar ICL; 16 eyes). The distance between the phakic IOL and the crystalline lens and the cornea as well as rotation around the optical axis was evaluated using Scheimpflug photography at 1, 3 to 6, and 12 months postsurgery. RESULTS: The anterior chamber phakic IOLs showed no significant movement in anteroposterior direction. The posterior chamber phakic IOL showed a significant movement toward the crystalline lens between postoperative months 3 and 12. The median amount of rotation around the optical axis between the 3- and the 12-month evaluation was 1.9 degrees (range = 0.0-33.5 degrees) for the NuVita, 0.6 degrees (range = 0.0-3.5 degrees) for the Artisan, and 0.9 degrees (range = 0.2-2.3 degrees) for the ICL. Four NuVita IOLs rotated more than 10 degrees. CONCLUSIONS: The angle-supported anterior chamber phakic IOLs showed a generally stable position regarding distance to cornea and natural lens, but rotation was observed in four IOLs. The iris-fixated phakic IOL showed the highest overall stability. The posterior chamber phakic IOL was stable in terms of rotation but had a tendency to decrease in distance toward the crystalline lens. Intraocular lenses implanted in phakic eyes followed for 12 months demonstrate stable IOL position overall.

Adult↗

Clinical course of severe central epithelial defects in laser in situ keratomileusis.

PURPOSE: To report the clinical outcome of laser in situ keratomileusis (LASIK) cases complicated by severe central intraoperative epithelial defects (EDs) caused by the microkeratome cut. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: In a retrospective study of 1650 LASIK cases at 1 center, the preoperative data, surgical procedures, and postoperative course in 22 eyes of 14 patients who experienced severe central EDs during the LASIK procedure (1.3%) were reviewed. The surgery was performed using a Technolas C-LASIK 217 excimer laser (Bausch & Lomb) and a Hansatome microkeratome (Bausch & Lomb). A follow-up of at least 12 months was available in all but 1 case. The median follow-up was 13.5 months (range 12 to 25 months). In the postoperative period, the following parameters were reviewed: course of refraction, best spectacle-corrected visual acuity (BSCVA), slitlamp findings, and corneal topography. RESULTS: The mean patient age was 42 years (range 27 to 61 years). Eight patients were affected bilaterally. Fifteen eyes (68%) had moderate to severe dry-eye symptoms preoperatively. Almost all eyes lost BSCVA in the postoperative period, and visual acuity improved slowly. By the last follow-up visit, no eye had lost more than 1 line of BSCVA. Diffuse lamellar keratitis (DLK) was observed in 20 eyes (91%), irregular astigmatism in 17 (77%), and microfolds in 12 (55%). In unilaterally affected patients, the refractive outcome was better in the nonaffected eye. CONCLUSIONS: A large central ED is a severe intraoperative complication of LASIK that may lead to DLK, irregular astigmatism, flap microfolds, clearly prolonged visual rehabilitation, and temporary loss of BSCVA. The improvement in BSCVA may take several months.

Adult↗

Ten-year follow-up of a ciliary sulcus-fixated silicone phakic posterior chamber intraocular lens.

In 1992, a ciliary sulcus-fixated, silicone, phakic posterior chamber intraocular lens (PPC IOL) (Adatomed, Fyodorov type) was implanted in both eyes of a 42-year-old white woman to correct high myopia (right eye, -17.0 diopters [D]; left eye, -11.5 D). In the right eye, localized cortical opacification was present in the anterior part of the natural lens preoperatively but did not progress during a 10-year follow-up period. With Scheimpflug photography, it was possible to detect a space between the natural lens and the IOL that was not evident on slitlamp examination. Maintenance of space between an IOL and the natural lens appears to be an important factor in preventing cataract formation after PPC IOL implantation.

Cataract↗

Correlation of infrared pupillometers and CCD-camera imaging from aberrometry and videokeratography for determining scotopic pupil size.

PURPOSE: To compare 2 infrared pupillometers with a videokeratographer and 2 aberrometers for the determination of scotopic pupil size. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: The pupil diameter was measured in 100 eyes of 51 patients after 2 minutes of dark adaptation using the following devices: digital infrared pupillometer (Procyon Instruments Ltd.), handheld infrared pupillometer (Colvard) (Oasis Medical), Zywave aberrometer (Bausch & Lomb), Wasca aberrometer (Asclepion-Meditec-Zeiss), and Orbscan II topography system (Bausch & Lomb Surgical). Measurements taken with the Procyon pupillometer were considered reference values for comparison with the other devices. Statistical evaluation was performed using the Bland-Altmann method for comparison of measurement techniques. RESULTS: The mean pupil size was 6.10 mm +/- 0.86 (SD) with the Procyon pupillometer, 5.68 +/- 1.07 mm with the Colvard pupillometer, 5.91 +/- 1.01 mm with the Zywave aberrometer with the fixating target turned off, 5.09 +/- 1.14 mm with the Zywave aberrometer with the fixating target turned on, 5.59 +/- 0.99 mm with the Wasca aberrometer, and 3.75 +/- 0.67 mm with the Orbscan topographer. The limits of agreement were smallest for measurements between Procyon and Colvard and largest for measurements between Procyon and Orbscan. The sign test revealed statistically significant differences for all devices compared with the Procyon pupillometer (P<.001 in all cases) except the Zywave aberrometer with the fixating target turned off (P=.13). CONCLUSIONS: The Zywave wavefront sensor with the fixating target turned off using the study settings and light conditions provided measurements of scotopic pupil diameter that were closest to the reference values (Procyon). With the other devices (Colvard pupillometer, Zywave aberrometer with the fixating target switched on, Wasca aberrometer, and Orbscan topographer), the difference was statistically significant.

Adult↗

Wavefront-guided LASIK with the Zyoptix 3.1 system for the correction of myopia and compound myopic astigmatism with 1-year follow-up: clinical outcome and change in higher order aberrations.

OBJECTIVE: To assess safety, efficacy, predictability, stability, and change in aberrations after wavefront-guided LASIK for myopia and myopic astigmatism. DESIGN: Prospective, nonrandomized, self-controlled trial. PARTICIPANTS: Wavefront-guided LASIK was performed in 97 eyes in a 1-year trial. Treated eyes had a mean subjective manifest spherical equivalent (SE) of -5.22+/-2.07 diopters (D), with a range of -0.25 to -9.00 D of myopia and 0 to -3.25 D of astigmatism. INTERVENTION: After a microkeratome cut, a wavefront-based excimer ablation (Zyoptix 3.1) was performed. The full treatment to achieve emmetropia of an early nomogram provided by the system manufacturer was used in all procedures. MAIN OUTCOME MEASURES: Safety, efficacy, predictability, and stability were evaluated at 1, 3, and 12 months postoperatively. Wavefront changes of higher order aberrations (HOAs) at 1 year were determined for pupil sizes of 3.5 and 6 mm. RESULTS: At 1 year postoperatively, uncorrected visual acuity (VA) was 20/20 or better in 83% of the eyes, and 20/40 or better in 98%. The mean subjective manifest SE at 1 year was -0.25+/-0.43 D; it was within 0.50 D in 77% and within 1.0 D in 95%. No eye lost > or =2 lines of best spectacle-corrected VA (BSCVA) at 1 year postoperatively; 40 eyes gained 1 line of BSCVA, and 5 eyes gained 2 lines. The total HOA root mean square (RMS) increased on average by a factor of 1.23+/-0.57 with a 3.5-mm pupil; for the 6 mm pupil, the increase factor was 1.52+/-0.36. No change or reduction in the total HOA RMS was observed in 45.5% of the eyes for a 3.5-mm pupil and in 20.6% for a 6-mm pupil. There was a significant increase of primary spherical aberration (Z 4,0) by a factor of 4.11+/-10.17 for 3.5-mm pupils and 4.31+/-6.76 for 6-mm pupils. CONCLUSIONS: Wavefront-guided LASIK using Zyoptix 3.1 is an effective and safe procedure for the treatment of myopia and myopic astigmatism. Although in close to half of the eyes HOAs could be reduced, there was still undercorrection and induction of HOAs with the algorithm employed.

Adult↗

Intraindividual comparison of epithelial defects during laser in situ keratomileusis using standard and zero-compression Hansatome microkeratome heads.

PURPOSE: To determine the difference between the standard and a modified (zero-compression) Hansatome microkeratome head (Bausch & Lomb) in the incidence of epithelial defects. SETTING: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. METHODS: Ninety-three patients (186 eyes) with a mean age of 39.1 years +/- 9.5 (SD) having laser in situ keratomileusis (LASIK) in both eyes were enrolled in a prospective randomized study using intraindividual comparison. In 1 eye, the flaps were created with the Hansatome microkeratome using the standard Hansatome head and in the other eye, the flaps were created with a microkeratome head with a modified design (zero-compression head). Intraoperative evaluation of epithelial defects was done using a standardized protocol. Statistical evaluation was performed with McNemar and Bowker tests. RESULTS: Epithelial defects occurred in 21 eyes (22.6%) in which the standard head was used and in 2 eyes (2.1%) in which the zero-compression head was used. In the former group, 15 (16.1%) of the epithelial defects were larger than 1.5 mm(2); the remaining 6 (6.4%) were smaller than 1.5 mm(2). In the latter group, both epithelial defects were smaller than 1.5 mm(2); both patients also had an epithelial defect in the eye in which the standard Hansatome head was used. The difference between the 2 Hansatome heads in the incidence (P<.001, McNemar) and size (P<.001, Bowker) of the epithelial defects was statistically significant. CONCLUSIONS: The Hansatome microkeratome with a zero-compression head significantly reduced the occurrence of intraoperative epithelial defects. The change in the construction of the Hansatome head is a useful improvement in LASIK technology.

Adolescent↗