PubMed Health⌕ Search

Biomedical subjects

Jens Dallüge

Publications and source records attributed to Jens Dallüge.

4 recordsLinked to original sources

Comprehensive two-dimensional gas chromatography: a powerful and versatile analytical tool.

Comprehensive two-dimensional gas chromatography (GC x GC) is a novel technique which is rapidly gaining importance for the analysis of complex samples. In the present review, attention is devoted to the principle and advantages, and main characteristics such as modulation, column combinations, detector requirements and data processing, of the technique. Specifically, GC x GC of a variety of real-life samples is discussed to demonstrate the applicability of the technique, with emphasis on the usefulness of the ordered-structure principle and on the analyte-identification power provided by a combination with time-of-flight mass spectrometric detection.

Chromatography, Liquid↗

Unravelling the composition of very complex samples by comprehensive gas chromatography coupled to time-of-flight mass spectrometry. Cigarette smoke.

The potential and current limitations of comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOF-MS) for the analysis of very complex samples were studied with the separation of cigarette smoke as an example. Because of the large number of peaks in such a GC x GC chromatogram it was not possible to perform manual data processing. Instead, the GC-TOF-MS software was used to perform peak finding, deconvolution and library search in an automated fashion; this resulted in a peak table containing some 30000 peaks. Mass spectral match factors were used to evaluate the library search results. The additional use of retention indices and information from second-dimension retention times can substantially improve the identification. The combined separation power of the GC x GC-TOF-MS system and the deconvolution algorithm provide a system with a most impressive separation power.

Automation↗

Evaluation of a high-resolution time-of-flight mass spectrometer for the gas chromatographic determination of selected environmental contaminants.

A benchtop high-resolution time-of-flight mass spectrometer (TOF MS) was evaluated for the determination of key organic microcontaminants. The major advantage of the TOF MS proved to be the high mass resolution of about 0.002 Da (10 ppm). Consequently, the detectability of polar pesticides, polynuclear aromatic hydrocarbons and polychlorinated biphenyls is excellent, and detection limits are in the order of 1-4 pg injected mass. Best mass spectral resolution was obtained for medium-scale peaks. It is a disadvantage that the calibration range is rather limited, viz. to about two orders of magnitude. The high mass spectral resolution was especially useful to improve the selectivity and sensitivity when analyzing target compounds in complex samples and to prevent false-positive identifications.

Calibration↗

Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection applied to the determination of pesticides in food extracts.

The separation provided by conventional gas chromatography (1D-GC) can be significantly enhanced by using comprehensive two-dimensional GC (GC X GC) instead. Combination with mass spectrometric detection is desirable for unambiguous confirmation of target compounds and the provisional identification of unknowns. A GC X GC system using a cryogenic modulator was coupled to a time-of-flight mass spectrometric (TOF MS) detector. With the determination of pesticides in vegetable extracts as an example, it was demonstrated that GC X GC improves the separation dramatically. All 58 pesticides of interest could be identified using their full-scan mass spectra, which was not possible when using ID-GC-TOF MS. In addition, the high scan speed of the TOF MS allowed the deconvolution of compounds partly co-eluting in GC X GC.

Chromatography, Gas↗