PubMed Health⌕ Search

Biomedical subjects

Jens Griep-Raming

Publications and source records attributed to Jens Griep-Raming.

4 recordsLinked to original sources

Chelation-controlled radical chain reactions studied by electrospray ionization mass spectrometry.

Electrospray ionization mass spectrometry (ESI-MS) is a novel tool for the investigation of chemical reactions in solution and for the direct detection and identification of reactive intermediates. The tributyltin hydride mediated addition of tert-butyl iodide to dimethyl 2-cyclohexyl-4-methyleneglutarate (2) in the presence of Lewis acids was investigated by ESI-MS using a microreactor coupled on-line to an ESI mass spectrometer. For the first time we have been able to show that transient radicals in radical chain reactions can be detected unambiguously under steady-state conditions in the reaction solution and can be characterized by ESI-MS/MS and accurate mass determination. The detection of different heterodimer radical complexes by ESI-MS/MS has provided new insights into the mechanism of Lewis acid controlled radical chain reactions. Dimeric chelate complexes of glutarates, such as 2 and 3, and Lewis acids, like Sc(OTf)3, MgBr2OEt2 and LiClO4, were observed as well as higher aggregates with additional equivalents of Lewis acid. Evidence for a dynamic equilibrium of the complexes in solution was found by NMR spectroscopy. The ESI-MS investigation of the chelation of glutarate 2 with various Lewis acids has led to the conclusion that the tendency for Lewis acids to form dimeric chelate complexes and higher aggregates has an important effect on the stereoselective outcome of the radical reactions.

Journal Article↗

High-throughput miniature cylindrical ion trap array mass spectrometer.

A fully multiplexed cylindrical ion trap (CIT) array mass spectrometer with four parallel ion source/mass analyzer/detector channels has been built to allow simultaneous high-throughput analysis of multiple samples. A multielement external chemical ionization/electron ionization source was coupled to a parallel array of CITs each of equal size (internal radius 2.5 mm), and the signal was recorded using an array of four miniature (2-mm inner diameter) electron multipliers. Using external electron ionization, the spectra of four separate samples were recorded simultaneously in real time using a four-channel preamplifier system and a data acquisition program written using LabVIEW software. These experiments mark the first demonstration of externally generated ions being successfully trapped in a miniature CIT mass analyzer. The instrument currently provides mass/charge range of approximately m/z 50-500. Average peak width is m/z 0.3, corresponding to a resolution of 1000 at m/z 300. The four-channel mass spectrometer is housed in a single vacuum manifold and operated with a single set of control electronics. The modular design of this instrument allows scale-up to many more channels of analysis for future applications in the areas of industrial process monitoring and combinatorial analysis and in the fields of proteomics and metabolomics.

Journal Article↗

Miniature cylindrical ion trap mass spectrometer.

A miniature cylindrical ion trap mass spectrometer is described, and preliminary data are presented. Functionality and performance of laboratory-scale instruments have been maintained to the extent possible in this battery-operated mass spectrometer. Capabilities include tandem mass spectrometry experiments. Custom-designed electronic components include the RF scanning and amplification system, data acquisition components, and lens power supplies, as well as a custom-software application. Direct leak and membrane introduction inlet systems are used for sample introduction. A mass/charge range of approximately 250 Th with unit mass resolution has been demonstrated.

Journal Article↗