PubMed Health⌕ Search

Biomedical subjects

Jerry Markman

Publications and source records attributed to Jerry Markman.

3 recordsLinked to original sources

Toward automated quality assurance for intensity- modulated radiation therapy.

PURPOSE: To investigate whether high-quality, relatively inexpensive, document and transparency scanners used as densitometers are sufficiently quantitative for routine quality assurance (QA). METHODS AND MATERIALS: The scanner we investigated used a linear amplifier, digitizing gray-scale images to 12-bit resolution with a user-selected spatial resolution of 0.170 mm(2) pixels. To reduce Newton's rings artifacts, the standard glass platen was replaced by glass with an antireflective coating. Conversion of reading to transmission was conducted by permanently placing a calibrated photographic step tablet on the scanner platen. After conversion to light transmission, a zero-phase two-dimensional Wiener filter was used to reduce pixel-to-pixel signal variation. Light-scatter artifacts were removed by deconvolution of a measured light-spread kernel. The light-spread kernel artifacts were significant along the scanner's detector axis, but were insignificant along the scanning axis. RESULTS: Pixel-to-pixel noise was better than 2% for optical densities, ranging from 0.4 to 2.0 and 0 to 2.7 for the unfiltered and filtered images, respectively. The document scanning system response was compared against a confocal scanning laser densitometer. A series of IMRT dose distribution and dose calibration film sets were scanned using the two scanners, and the measured dose was compared. The maximum mean and standard deviation of the measured dose difference between the document scanner and confocal scanner was 1.48% and 1.06%, respectively. CONCLUSION: While the document scanners are not as flexible as dedicated film densitometers, these results indicate that, using the intensity and scatter corrections, the system provides accurate and precise measurements up to an optical density of 2.0, sufficient for routine IMRT film QA. For some film types, this requires the reduction in monitor units to limit the dose delivered to the film. The user must be cautious that the delivered IMRT dose is scaled appropriately. This inexpensive and accurate system is being integrated into an automated QA program.

Artifacts↗

Applicator-guided intensity-modulated radiation therapy.

PURPOSE: We are introducing a novel method for delivering highly conformal dose distributions to cervical cancer tumors using external beam intensity-modulated radiation therapy. The method, termed applicator-guided intensity-modulated radiation therapy (AGIMRT), will use an applicator substitute placed in the vagina and uterus to provide spatial registration and immobilization of the gynecologic organs. The main reason for the applicator substitute will be to localize the fornices, cervix, and uterus with the expectation that the other nearby organs will also be reproducibly positioned with respect to the applicator substitute. Intensity-modulated radiation therapy (IMRT) dose distributions will be used as a substitute for high-dose-rate intracavitary brachytherapy procedures. The flexibility of IMRT will enable customized dose distributions that have the potential to reduce complications and improve local control, especially for locally advanced disease. METHODS AND MATERIALS: To test the advantages of IMRT over intracavitary brachytherapy, volumetric scans of three cervical cancer patients were obtained with implanted CT-compatible applicators. IMRT dose distribution simulations using tomotherapy, were compared against intracavitary brachytherapy using cesium tubes to investigate the dosimetric differences of the two modalities. Because these tumor volumes do not image well on CT, the target volumes were defined as the isodose surface containing the traditional point A, defined as 2 cm superior to the vaginal fornices and 2 cm lateral to the intrauterine canal. One patient had a uterus that wrapped superior and anterior to the bladder. For this case, the cervix and uterus were selected as the target volume. To determine the potential for using an applicator substitute to localize internal organs, the posterior bladder and anterior rectal surfaces were localized relative to the colpostats. Comparisons of the colpostat-localized surfaces were conducted for two scan studies for 3 patients. RESULTS: The IMRT distributions covered the point-A isodose surfaces while reducing doses to the bladder and rectum. Brachytherapy showed extensive underdose regions in the target volume for the wrapped-around target. Spatial positioning was better than 0.7 and 1.3 cm in the rectum and bladder, respectively, indicating the potential that an applicator substitute may be able to localize these structures. CONCLUSIONS: AGIMRT has the potential for improving critical structure avoidance while maintaining highly reproducible and accurate internal organ registration found with brachytherapy.

Female↗

Beyond bixels: generalizing the optimization parameters for intensity modulated radiation therapy.

Intensity modulated radiation therapy (IMRT) treatment planning systems optimize fluence distributions by subdividing the fluence distribution into rectangular bixels. The algorithms typically optimize the fluence intensity directly, often leading to fluence distributions with sharp discontinuities. These discontinuities may yield difficulties in delivery of the fluence distribution, leading to inaccurate dose delivery. We have developed a method for decoupling the bixel intensities from the optimization parameters; either by introducing optimization control points from which the bixel intensities are interpolated or by parametrizing the fluence distribution using basis functions. In either case, the number of optimization search parameters is reduced from the direct bixel optimization method. To illustrate the concept, the technique is applied to two-dimensional idealized head and neck treatment plans. The interpolation algorithms investigated were nearest-neighbor, linear and cubic spline, and radial basis functions serve as the basis function test. The interpolation and basis function optimization techniques were compared against the direct bixel calculation. The number of optimization parameters were significantly reduced relative to the bixel optimization, and this was evident in the reduction of computation time of as much as 58% from the full bixel optimization. The dose distributions obtained using the reduced optimization parameter sets were very similar to the full bixel optimization when examined by dose distributions, statistics, and dose-volume histograms. To evaluate the sensitivity of the fluence calculations to spatial misalignment caused either by delivery errors or patient motion, the doses were recomputed with a 1 mm shift in each beam and compared to the unshifted distributions. Except for the nearest-neighbor algorithm, the reduced optimization parameter dose distributions were generally less sensitive to spatial shifts than the bixel optimization. These results indicate that significant reductions in optimization parameter sets can be accomplished with a negligible reduction in dose distribution quality. The decreased parameters can result in a reduced optimization time, or can be used to allow an improved and consequently more computation-intensive dose calculation for more accurate dose calculations during the optimization process. The basis functions may be generalized to model the accelerator motion for direct computation of the accelerator motion sequence, removing the need for developing an independent leaf sequence step.

Algorithms↗