Jerzy Bodurka

Publications and source records attributed to Jerzy Bodurka.

7 recordsLinked to original sources

How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan duration.

Recent advances in MRI receiver and coil technologies have significantly improved image signal-to-noise ratios (SNR) and thus temporal SNR (TSNR). These gains in SNR and TSNR have allowed the detection of fMRI signal changes at higher spatial resolution and therefore have increased the potential to localize small brain structures such as cortical layers and columns. The majority of current fMRI processing strategies employ multi-subject averaging and therefore require spatial smoothing and normalization, effectively negating these gains in spatial resolution higher than about 10 mm3. Reliable detection of activation in single subjects at high resolution is becoming a more common desire among fMRI researchers who are interested in comparing individuals rather than populations. Since TSNR decreases with voxel volume, detection of activation at higher resolutions requires longer scan durations. The relationship between TSNR, voxel volume and detectability is highly non-linear. In this study, the relationship between TSNR and the necessary fMRI scan duration required to obtain significant results at varying P values is determined both experimentally and theoretically. The results demonstrate that, with a TSNR of 50, detection of activation of above 2% requires at most 350 scan volumes (when steps are taken to remove the influence of physiological noise from the data). Importantly, these results also demonstrate that, for activation magnitude on the order of 1%, the scan duration required is more sensitive to the TSNR level than at 2%. This study showed that with voxel volumes of approximately 10 mm3 at 3 T, and a corresponding TSNR of approximately 50, the required number of time points that guarantees detection of signal changes of 1% is about 860, but if TSNR increases by only 20%, the time for detection decreases by more than 30%. More than just being an exercise in numbers, these results imply that imaging of columnar resolution (effect size=1% and assuming a TR of 1 s) at 3 T will require either 10 min for a TSNR of 60 or 40 min for a TSNR of 30. The implication is that at these resolutions, TSNR is likely to be critical for determining success or failure of an experiment.

Algorithms↗

Direct magnetic resonance detection of neuronal electrical activity.

Present noninvasive neuroimaging methods measure neuronal activity indirectly, via either cerebrovascular changes or extracranial measurements of electrical/magnetic signals. Recent studies have shown evidence that MRI may be used to directly and noninvasively map electrical activity associated with human brain activation, but results are inconclusive. Here, we show that MRI can detect cortical electrical activity directly. We use organotypic rat-brain cultures in vitro that are spontaneously active in the absence of a cerebrovascular system. Single-voxel magnetic resonance (MR) measurements obtained at 7 T were highly correlated with multisite extracellular local field potential recordings of the same cultures before and after blockade of neuronal activity with tetrodotoxin. Similarly, for MR images obtained at 3 T, the MR signal changed solely in voxels containing the culture, thus allowing the spatial localization of the active neuronal tissue.

Animals↗

Improved BOLD detection in the medial temporal region using parallel imaging and voxel volume reduction.

Using gradient-echo EPI, signal dropout due to macroscopic off resonance effects can prevent blood-oxygenation-level-dependent (BOLD) signal change detection. The anterior medial temporal lobe (MTL) is located near these susceptibility gradients and therefore shows considerable signal dropout with GE-EPI. Reducing the volume of the image voxel reduces susceptibility-related signal dropout. However, this is accompanied by a prohibitive reduction in signal-to-noise ratio (SNR). To compensate for SNR loss with smaller voxels, we used a multi-channel MRI receiver with an array of receive-only 16-element surface coils at 3 T. We demonstrate that the reduction of susceptibility artifacts, through use of high resolution images, coupled with the gains in image SNR from the array coil improves the temporal signal-to-noise ratio (TSNR) and enhances the contrast-to-noise ratio (CNR). Furthermore, a comparison of 2 mm with 4-mm-thick axial images both with the same in-plane resolution showed that thinner slices enhanced TSNR and CNR throughout the ventral-medial regions of the temporal lobes, with the greatest improvement in the most anterior regions of the MTL. Further improvements were seen when adjacent 2 mm slices were combined to match overall voxel volume. These results demonstrate that BOLD investigation of anterior MTL function can be enhanced by decreasing voxel size but only in combination with the SNR gained by using the 16-channel head coil system.

Adult↗

Unraveling multisensory integration: patchy organization within human STS multisensory cortex.

Although early sensory cortex is organized along dimensions encoded by receptor organs, little is known about the organization of higher areas in which different modalities are integrated. We investigated multisensory integration in human superior temporal sulcus using recent advances in parallel imaging to perform functional magnetic resonance imaging (fMRI) at very high resolution. These studies suggest a functional architecture in which information from different modalities is brought into close proximity via a patchy distribution of inputs, followed by integration in the intervening cortex.

Acoustic Stimulation↗

Signal-to-noise ratio and parallel imaging performance of a 16-channel receive-only brain coil array at 3.0 Tesla.

The performance of a 16-channel receive-only RF coil for brain imaging at 3.0 Tesla was investigated using a custom-built 16-channel receiver. Both the image signal-to-noise ratio (SNR) and the noise amplification (g-factor) in sensitivity-encoding (SENSE) parallel imaging applications were quantitatively evaluated. Furthermore, the performance was compared with that of hypothetical coils with one, two, four, and eight elements (n) by combining channels in software during image reconstruction. As expected, both the g-factor and SNR improved substantially with n. Compared to an equivalent (simulated) single-element coil, the 16-channel coil showed a 1.87-fold average increase in brain SNR. This was mainly due to an increase in SNR in the peripheral brain (an up to threefold SNR increase), whereas the SNR increase in the center of the brain was 4%. The incremental SNR gains became relatively small at large n, with a 9% gain observed when n was increased from 8 to 16. Compared to the (larger) product birdcage head coil, SNR increased by close to a factor of 2 in the center, and by up to a factor of 6 in the periphery of the brain. For low SENSE acceleration (rate-2), g-factors leveled off for n>4, and improved only slightly (1.4% averaged over brain) going from n=8 to n=16. Improvements in g for n>8 were larger for higher acceleration rates, with the improvement for rate-3 averaging 12.0%.

Brain Mapping↗

Scalable multichannel MRI data acquisition system.

A scalable multichannel digital MRI receiver system was designed to achieve high bandwidth echo-planar imaging (EPI) acquisitions for applications such as BOLD-fMRI. The modular system design allows for easy extension to an arbitrary number of channels. A 16-channel receiver was developed and integrated with a General Electric (GE) Signa 3T VH/3 clinical scanner. Receiver performance was evaluated on phantoms and human volunteers using a custom-built 16-element receive-only brain surface coil array. At an output bandwidth of 1 MHz, a 100% acquisition duty cycle was achieved. Overall system noise figure and dynamic range were better than 0.85 dB and 84 dB, respectively. During repetitive EPI scanning on phantoms, the relative temporal standard deviation of the image intensity time-course was below 0.2%. As compared to the product birdcage head coil, 16-channel reception with the custom array yielded a nearly 6-fold SNR gain in the cerebral cortex and a 1.8-fold SNR gain in the center of the brain. The excellent system stability combined with the increased sensitivity and SENSE capabilities of 16-channel coils are expected to significantly benefit and enhance fMRI applications.

Brain↗

Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes.

A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrical currents produced by neuronal activity. The method involves the detection of NMR phase changes that occur during a single-shot spin-echo (SE) echo-planar sequence (EPI) echo time. SE EPI effectively rephases all changes in B(0) that occur on a time scale longer than the echo time (TE) and amplifies all DeltaB(0) changes that occur during TE/2. The method was tested on a phantom that contains wires in which current can be modulated. The sensitivity and flexibility of the technique was demonstrated by modulation of the temporal position and duration of the stimuli-evoked transient magnetic field relative to the 180 RF pulse in the imaging sequence-requiring precise stimulus timing. Currently, with this method magnetic field changes as small as 2 x 10(-10) T (200 pT) and lasting for 40 msec can be detected. Implications for direct mapping of brain neuronal activity with MRI are discussed.

Brain Mapping↗