Behaviour and design considerations for continuous flow closed-open-closed liquid microchannels.

This paper introduces a method of combining open and closed microchannels in a single component in a novel way which couples the benefits of both open and closed microfluidic systems and introduces interesting on-chip microfluidic behaviour. Fluid behaviour in such a component, based on continuous pressure driven flow and surface tension, is discussed in terms of cross sectional flow behaviour, robustness, flow-pressure performance, and its application to microfluidic interfacing. The closed-open-closed microchannel possesses the versatility of upstream and downstream closed microfluidics along with open fluidic direct access. The device has the advantage of eliminating gas bubbles present upstream when these enter the open channel section. The unique behaviour of this device opens the door to applications including direct liquid sample interfacing without the need for additional and bulky sample tubing.

Equipment Design↗

A fast passive and planar liquid sample micromixer.

A novel microdevice for passively mixing liquid samples based on surface tension and a geometrical mixing chamber is presented. Due to the laminar flow regime on the microscale, mixing becomes difficult if not impossible. We present a micromixer where a constantly changing time dependent flow pattern inside a two sample liquid plug is created as the plug simply passes through the planar mixer chamber. The device requires no actuation during mixing and is fabricated using a single etch process. The effective mixing of two coloured liquid samples is demonstrated.

Journal Article↗

Characterization of micromachined hollow tips for two-dimensional nanoelectrospray mass spectrometry.

In this work an improved design of chip-based nanoelectrospray nozzles is reported. Two-dimensional matrices of out-of-plane 10 microm i.d. silicon dioxide tips with a tapered shape were manufactured using deep reactive ion etching technology. Using a peptide sample, six micromachined tips and six commercially pulled silica capillary tips were compared employing an ion trap mass spectrometer. At a flow rate of 100 nL/min, the detectability obtained was approximately the same for the two types of tips. The relative standard deviation of the signal-to-noise ratio for the peptides between six different tips was on average 22% for the micromachined tips and 45% for the pulled capillary tips. The usefulness of the micromachined tips for analysis of non-covalent protein-ligand complexes was demonstrated by the analysis of a sample of RNase A and cytidine 2'-monophosphate. In another test, analyzing a tryptic digest of 1 pmol/microL cytochrome C, 18 peptides corresponding to a 82% sequence coverage were detected. Using MS/MS, the whole sequence of an 11 amino acid cytochrome C fragment was obtained. Computer simulations were performed on the shape and magnitude of the electrical field around micromachined and pulled capillary tips. To reach the threshold electric field density at the tip apex required to initiate an electrospray, a higher electrospray voltage was needed for the chip-based tips compared with pulled capillary tips. This is due to the influence of the chip base.