MagScrew total artificial heart in vivo performance above 200 beats per minute.

PURPOSE: Downsizing pulsatile devices requires an increase of beat rate if flow capacity is to be maintained. We applied this concept to the preclinical MagScrew total artificial heart (TAH). DESCRIPTION: The device fills passively with a stroke volume of 45 ml and beat rates up to 250 beats per minute (bpm). EVALUATION: Stable hemodynamics were observed during a 30-day bovine implant with a flow of 8.7 +/- 1.2 L/min at beat rates of 204 +/- 18 bpm. Device filling was exceptional up to 250 bpm generating flow of greater than 12 L/min. Beat rate adapted to preload in a way similar to a Frank-Starling response. Left and right atrial pressures were balanced. The aortic pulse pressure was 49-70 mm Hg, which translates to a pulsatility index of 0.49-0.77. Organ functions were preserved and blood damage did not occur. CONCLUSIONS: Increasing the beat rate while downsizing the MagScrew TAH was successful with strong flow generation by passive filling. Pulsatility was maintained at high beat rates. This innovative approach may be used to develop small pulsatile pumps.

Animals↗

A signal process method for DNA segments separation in micro-channel electrophoresis.

This paper presents a signal process method for DNA segments separation in micro-channel electrophoresis. It is developed and optimized by using a laser induced fluorescence (LIF) based detection system. In this detection system, signal is sampled and processed through a novel signal process module. The results show that this signal process method provides good signal-to-noise ratios and lower limit of detection (LOD).

DNA↗

Chronic evaluation of the Cleveland Clinic CorAide left ventricular assist system in calves.

The Cleveland Clinic CorAide left ventricular assist system is based on a third-generation, implantable, centrifugal pump in which a rotating assembly is suspended fully. To evaluate chronic in vivo system performance and biocompatibility, the CorAide blood pump was implanted in 18 calves for either 1 month or 3 months. Hemodynamics were stable in all calves with a mean pump flow of 5.9 +/- 1.2 L/min and a mean systemic arterial pressure of 98 +/- 5 mm Hg. There were no incidences of bleeding, organ dysfunction, or mechanical failure in any of the 18 calves. Hemolysis occurred in only 1 calf due to outflow graft stenosis. Thrombus inside the pump, seen in 4 of the first 6 cases, was totally eliminated by a final redesign in the remaining cases, including the last 6 implants conducted without anticoagulation therapy. The CorAide blood pump demonstrated good biocompatibility and reliable, effective system performance.

Animals↗

Cleveland clinic CorAide blood pump circulatory support without anticoagulation.

The Cleveland Clinic CorAide left ventricular assist system consists of a permanently implantable centrifugal pump in which the rotating assembly is completely suspended and noncontacting. A series of chronic animal in vivo studies were conducted to evaluate the biologic effects of CorAide circulatory support without the use of anticoagulation therapy. The CorAide pump was implanted in six calves (five calves for 21 to 32 days and one calf for 95 days). The first five calves received intravenous heparin during the early postoperative periods (2-7 days). Heparin administration was then discontinued and no other anticoagulant drugs were used for the duration of the experiments. The last calf did not receive any anticoagulant except for a bolus dose of heparin (200 U/kg) during surgery. Hemodynamics were stable in all six calves, with a mean pump flow of 5.6+/-1.2 L/min and mean arterial pressure of 100+/-4 mm Hg. The blood pump surfaces were clean of thrombus in all six calves. Significant findings at autopsy were limited to one case of renal infarction. There was no incidence of mechanical failure, bleeding, or device infection. The CorAide pump can be safely run with minimal or no anticoagulant therapy.

Animals↗

In vivo performance and biocompatibility of the MagScrew ventricular assist device.

Currently available ventricular assist devices (VADs) have limitations in long-term durability and blood compatibility. We evaluated a prototype of a pulsatile MagScrew VAD for in vivo hemodynamic performance and biocompatibility. The device is composed of an actuator, blood pump housing, diaphragm, pusher plate, and bioprosthetic valves. Its protein-coated ("biolized") blood-contacting surface inhibits clot formation. Forces between moving parts of the actuator are transmitted magnetically, eliminating a primary source of friction and wear. The pump fills passively and is highly preload sensitive. The device was implanted into three calves for 90, 10, and 57 days, respectively. No anticoagulants were given postoperatively. The device functioned without technical problems during the entire course of each experiment, with mean device flow ranging between 5.4 and 9.0 L/min. Autopsy of the first two calves revealed no sign of embolization and clean blood-contacting surfaces of the devices. The third experiment was complicated by a prosthetic valve endocarditis with infectious embolization, and a few small depositions were found in the pump. In conclusion, the MagScrew VAD has demonstrated a high level of performance and biocompatibility in three calves studied for 10-90 days. Vigorous development is in progress to bring this device to preclinical readiness and thus provide surgeons with the VAD of choice for permanent implantation.

Animals↗

In vitro performance of the novel coronary sinus AutoRetroPerfusion Cannula.

Myocardial salvage through coronary sinus intervention has been documented. The AutoRetroPerfusion Cannula is a novel device that is able to perfuse the coronary bed retrogradely through the coronary sinus with arterial blood generated from a peripheral artery with no need for a pump. The cannula consists of a distal end that, once secured in the coronary sinus, opens an umbrella-like membrane to create pressure in the coronary sinus, and at the same time has small channels directed backwards to the right atrium to provide pressure relief. The cannula is introduced from the axillary vein under local anesthesia and the proximal end, which consists of a graft, is anastomosed to the axillary artery to start autoperfusion once the distal end is secured in the coronary sinus and the occluding membrane is open. The AutoRetroPerfusion Cannula was tested in the in vitro mock loop under 50-120 mm Hg of proximal pressure and 50, 100, and 150 ml/min of total flow in the cannula. We were able to achieve the nominal design point of 40-80 mm Hg of distal pressure and 50-150 ml/min of distal flow by adjusting the number, diameter, and length of the small backwards channels.

Biomedical Engineering↗

Development of a small implantable right ventricular assist device.

The purpose of this program is to design, develop, and clinically evaluate a new, implantable right ventricular assist device (RVAD) that can be used as a component of an implantable biventricular assist device for patients with severe biventricular heart failure. The initial phase of this program resulted in a prototype RVAD, named DexAide, a modified version of the CorAide left ventricular assist device. In vitro testing was performed in a stand-alone circuit and in a true RVAD mode to evaluate pump performance. Pump flow and power were measured under various afterload and pump speed conditions. The pump performance requirements of 2 to 6 l/min and a pressure rise of 20 to 60 mm Hg were successfully met with pump speeds between 1,800 and 3,200 rpm. The nominal design point of 4 l/min and 40 mm Hg pressure rise was achieved at 2,450 +/- 70 rpm with a power consumption of 3.0 +/- 0.2 W. The initial in vitro testing met the design criteria for the new DexAide RVAD. Initial in vivo testing is under way, which will be followed by preclinical readiness testing and a pilot clinical trial in this 5-year program.

Biomedical Engineering↗

MagScrew TAH: an update.

The MagScrew Total Artificial Heart (TAH) system is the result of a close collaboration among the Cleveland Clinic Foundation, Foster Miller Technologies, Wilson Greatbatch Ltd, and Whalen Biomedical Inc. The system components are the thoracic blood pumping unit with attached compliance chamber and refill port, implantable electronic control unit, implantable battery pack, transcutaneous energy transmission system, external battery pack, and a telemetry system for communication with the electronic control unit. System in vitro tests are underway for system characterization and durability demonstration, whereas in vivo tests were conducted to evaluate system performance and biocompatibility under physiologic conditions. The passively filling pump uses a left master alternate left and right ejection control mode and has a Starling law-like response to venous pressure. The in vitro tests documented excellent hydraulic pump performance with high device output of over 9 l/min at left atrial pressures below 12 mm Hg. Atrial balance was well maintained under all test conditions. The in vivo tests demonstrated good biocompatibility without use of anticoagulant therapy. Experimental durations have ranged between 0 and 92 days. Postexplant evaluation of tissue samples did not reveal any sign of thromboembolic events or tissue damage due to device operation.

Animals↗

Initial in vivo evaluation of the DexAide right ventricular assist device.

Despite the increasing use of left ventricular assist devices for patients with end-stage congestive heart failure, no implantable, centrifugal right ventricular assist devices (RVADs) are available for those patients with significant right ventricular failure. The DexAide RVAD was developed to provide an implantable RVAD option to surgeons. The aim of this study was to evaluate pump performance in an acute in vivo model. The DexAide RVAD, developed as a modified CorAide left ventricular assist device, was implanted between the right ventricle and the pulmonary artery in four healthy calves. Pump speed was varied from 1800 rpm to 3600 rpm. RVAD performance was analyzed acutely at baseline and under conditions of low circulating volume, high contractility, high pulmonary arterial pressure, vasodilation, and low contractility. Pump flow was well maintained even under conditions of high pulmonary arterial pressure and vasodilation, with the exception of low circulating volume. Under all conditions, pulmonary arterial pressures were not affected by changing pump speed. The DexAide RVAD demonstrated acceptable hemodynamic characteristics for use as an implantable RVAD in the initial acute studies. Further studies are ongoing to examine the biocompatibility of the pump under chronic conditions.

Animals↗

Development of patient-specific three-dimensional pediatric cardiac models.

The availability of algorithms to create three-dimensional (3D) models from medical images has made it possible to render and build patient-specific reconstructions of individual body parts. In the present study, this technology was used to create 3D models of pediatric hearts for use in medical device development. Digital models were created using CT datasets of pediatric hearts and commercially available 3D image processing software. Using this software, stacked CT data were viewed, and pixels representing the heart and rib cage were selected and rendered as 3D models. Stereolithography and 3D printing technology were used to create rigid and flexible physical heart models (biomodels) from the digital models. Twelve on-screen models of the thorax and cardiac structures were created from cardiac CT scans obtained from 11 patients with and without congenital heart disease (median age, 3 years; range, 2 days to 13 years). Rigid and flexible physical heart models were generated from the digital models to provide tactile and visual information. 3D models of pediatric cardiac and chest anatomy provide enhanced understanding and tactile representation of complex anatomy. Precise representation of the spatial relationships between anatomic structures is particularly useful during the development and placement of medical devices.

Algorithms↗

Replacement of the left-side valves of an implanted total artificial heart.

The MagScrew total artificial heart (TAH) is under development. Despite its anticipated durability and reliability, the possibility of a bioprosthetic valve malfunction exists. As a result, the potential for valve replacement surgery, instead of device replacement, would be desirable after a TAH implant. In two of our 90-day animal experiments, we successfully replaced the left-side valves through a left thoracotomy opposite to the right-sided incision site for the initial TAH implant. The results of these cases suggest that the left-side valves could also be replaced through a left thoracotomy approach in humans. To confirm the ability to access the left-side valves in humans, four human cadaver studies were performed with the use of a mock pump designed for human application. This report describes the operative techniques for left-side valve replacement in animals and discusses the advantages of a left thoracotomy in clinical situations, based on results from the human cadaver studies.

Animals↗

Progress in the development of the DexAide right ventricular assist device.

The DexAide right ventricular assist device (RVAD) is an implantable centrifugal pump modified from the CorAide left ventricular assist device. As previously published, in vitro performance testing of the DexAide RVAD has met design criteria, and the nominal operating condition of 4 l/min and 20 mm Hg pressure rise was achieved at 2,000 rpm, with a power consumption of 1.9 watts. In vivo studies in 14 calves have demonstrated acceptable hemodynamic characteristics. The calf inflow cannula design is still evolving to minimize depositions on the cannula observed in most experiments. Fitting studies were performed in 5 cadavers and 2 patients to reconfigure the cannulae for use in humans. The design and development of external electronics have been completed for the stand-alone RVAD system, and verification tests are under way in preparation for preclinical tests. Work on the external electronics design for the biventricular assist system is ongoing. In conclusion, the initial in vitro and in vivo studies have demonstrated acceptable hemodynamic characteristics of the DexAide RVAD. The design and development of the external electronic components for the stand-alone RVAD system have been completed. The calf inflow cannula is being redesigned, and chronic in vivo tests are under way.

Animals↗