PubMed Health⌕ Search

Biomedical subjects

Ji-Shan Li

Publications and source records attributed to Ji-Shan Li.

3 recordsLinked to original sources

Quartz crystal microbalance bioaffinity sensor for biotin based on mixed self-assembled monolayers and metastable molecular complex receptor.

A quartz crystal microbalance (QCM) sensor was proposed for the detection of small molecule biotin based on the mixed self-assembled monolayer (SAM) of thiols on gold substrate and the bioaffinity difference between an analyte (biotin) and an analogue compound (HABA) in binding avidin. Avidin formed a metastable complex with 2-[(4-hydroxyphenyl)azo]benzoic acid (HABA) immobilized on the crystal surface. When the sensor contacts a sample solution containing biotin, the avidin was released from the sensor surface to form a more stable complex with biotin in solution. The frequency change recorded is proportional to the desorbed mass of avidin, and there is a clear mathematic relationship between the frequency change and the biotin concentration. The use of mixed SAMs allows the stable attachment of bioreceptor molecules on the QCM, and enhances the amount of the immobilized molecules on the QCM, as a longer "space arm" in the mixed SAMs makes this monolayer membrane more accessible to capture the immobilized molecules. The proposed bioaffinity sensor has nice response to biotin in the range of 0.017-1.67 microg/mL. The sensor could be regenerated under very mild conditions simply by reimmersion of the sensor into a biotin solution to desorb the surplus avidin.

Azo Compounds↗

A sensitive immunoassay based on electropolymerized films by capacitance measurements for direct detection of immunospecies.

Fabrication of a capacitive immunosensor based on electropolymerized polytyramine (Pty) film for the direct detection of human serum albumin (HSA) without any labeling is described. The capacitance change of the heterostructures, Pty films/covalently bonded antibodies/buffered medium, is utilized for monitoring the specific antibody-antigen interaction. The Pty films are ultrathin and the HSA assay is nearly specific. Experimental parameters affecting antibody immobilization and the sensing of HSA are investigated in detail and optimized. This capacitive sensor prepared with the present method can provide high sensitivity. Under the optimized experimental conditions, a linear calibration curve in the concentration range 1.84-368.6 ng/ml when plotted vs the logarithm of the antigen concentration is obtained and the detection limit (S/N=3) is 1.60 ng/ml. After an acidic washing the present system can be used again. The applicability and reliability of the sensor are also demonstrated.

Animals↗

Piezoelectric immunoassay for complement C4 based on a Nafion-modified interface for antibody immobilization.

A piezoelectric immunosensor based on a Nafion membrane interface with a simple immobilization procedure has been developed for the determination of complement C4 in human serum. The polyanionic perfluorosulfonated Nafion polymer was used to modify the electrode surface of quartz-crystal microbalance (QCM) as a platform for the immobilization of complement C4 antibodies. The surface morphology of QCM modified with Nafion membrane was investigated using scanning electron microscopy. The system was optimized with regard to the parameters involved in the preparation of the immunosensor and the assay process. The proposed immunosensor responds well to C4 in the range of 0.08-1.6 microg/ml with a relative standard deviation of <5.3%. Moreover, the proposed immunosensor has advantages in terms of the speed and simplicity of the immobilization procedure as well as the simple and advantageous regeneration process. The experimental results obtained with regard to nonspecific adsorption and recovery indicate that the proposed immunosensor offers a promising alternative tool for the clinical diagnosis of complement C4.

Antibodies↗